Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging

被引:79
|
作者
Le Roux, P [1 ]
Gilles, RJ [1 ]
McKinnon, GC [1 ]
Carlier, PG [1 ]
机构
[1] Gen Elect Med Syst, Buc, France
来源
关键词
cardiac; fast imaging; fast spin-echo; outer volume suppression;
D O I
10.1002/jmri.1880080505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Among the ultrafast MRI techniques, the single-shot fast spin-echo sequence offers a robust alternative to echo planar imaging, essentially because of a much reduced sensitivity to B-o inhomogeneity. This property is particularly appealing in situations in which B, inhomogeneities can be severe and difficult to correct, such as in cardiac imaging. With single-shot cardiac imaging, however, achieving high resolution over the necessarily large field of views without introducing back-folding artifacts is problematic. One option is to use multishot sequences. However, then issues related to cardiac gating arise. Another solution is to use, optimized presaturation slabs with quadratic phase pulses generated by the Shinnar-LeRoux algorithm. These can be set to reduce the field of view in the phase-encoding direction, resulting in a reduction in the number of phase-encoding steps. For instance, for a 1 x 2-mm spatial resolution, over a rectangular, 250 x 125-mm held of view, and using a half Fourier acquisition, an echo-train length of only 40 is required. With a 4,5-msec echo spacing, the total imaging time is approximate to 180 msec, The efficacy of this solution on phantoms and volunteers is demonstrated. Multislice short-axis examinations of the whole heart, realized within a single short breath-hold of approximate to 10 seconds, are shown. The possibility of investigating not only cardiac anatomy but also both contractility and myocardial perfusion is discussed.
引用
收藏
页码:1022 / 1032
页数:11
相关论文
共 50 条
  • [1] Single-shot fast spin-echo MR imaging of the fetus: A pictorial essay
    Huppert, BJ
    Brandt, KR
    Ramin, KD
    King, BF
    [J]. RADIOGRAPHICS, 1999, 19 : S215 - S227
  • [2] Myocardial perfusion with ultra fast spin-echo single-shot echo-planar-imaging
    Pedro Ferreira
    Peter Gatehouse
    David Firmin
    [J]. Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [3] Diffusion tensor imaging of the spinal cord with a single-shot fast spin-echo sequence
    Hackney, DB
    Kharbanda, H
    Schwartz, ED
    Alsop, DC
    [J]. RADIOLOGY, 2000, 217 : 390 - 390
  • [4] Optimizing MR cholangiopancreatography with single-shot fast spin-echo and respiratory-triggered fast spin-echo sequences.
    Shiratori, Y
    Naiki, T
    Nagaki, M
    Murakami, N
    Kato, T
    Kanematsu, M
    Hoshi, H
    Moriwaki, H
    [J]. GASTROENTEROLOGY, 1998, 114 (04) : A542 - A542
  • [5] A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo
    T. K. Mittal
    S. F. S. Halpin
    M. W. Bourne
    M. D. Hourihan
    T. Perkins
    Y. Sun
    S. Tan
    [J]. Neuroradiology, 1999, 41 : 480 - 486
  • [6] A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo
    Mittal, TK
    Halpin, SFS
    Bourne, MW
    Hourihan, MD
    Perkins, T
    Sun, Y
    Tan, S
    [J]. NEURORADIOLOGY, 1999, 41 (07) : 480 - 486
  • [7] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    [J]. JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [8] Pancreatic cysts: Depiction on single-shot fast spin-echo MR images
    Zhang, XM
    Mitchell, DG
    Dohke, M
    Holland, GA
    Parker, L
    [J]. RADIOLOGY, 2002, 223 (02) : 547 - 553
  • [9] Single-shot fast spin-echo diffusion tensor imaging of the lumbar spine at 1.5 and 3 T
    Carballido-Gamio, Julio
    Xu, Duan
    Newitt, David
    Han, Eric T.
    Vigneron, Daniel B.
    Majumdar, Sharmila
    [J]. MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 665 - 670
  • [10] Clinical application of single-shot fast spin-echo sequence for cerebrospinal fluid flow MR imaging
    Bessho, Takahito
    Hayashi, Tatsuya
    Shibukawa, Shuhei
    Kourin, Kazuyuki
    Shouda, Takashi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (03) : 782 - 792