Type testing of a head band dosemeter for measuring eye lens dose in terms of Hp(3)

被引:21
|
作者
Gilvin, P. J. [1 ]
Baker, S. T. [1 ]
Gibbens, N. J. [1 ]
Roberts, G. H. [1 ]
Tanner, R. J. [1 ]
Eakins, J. S. [1 ]
Hager, L. G. [1 ]
Daniels, T. J. [1 ]
机构
[1] Ctr Radiat Chem & Environm Hazards, Publ Hlth England, Didcot OX11 0RQ, England
关键词
CONVERSION COEFFICIENTS; CALIBRATION; EXPOSURE; TLD;
D O I
10.1093/rpd/nct144
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new head band dosemeter, for the measurement of eye lens dose in terms of H-p(3), has been type tested by Public Health Englands Centre for Radiation, Environmental and Chemical Hazards [formerly part of the UK Health Protection Agency (HPA)]. The type tests were based on the International Standard ISO 12794, drawing also upon earlier work at HPA. The results show that, unlike many existing dosemeters, the new head band dosemeter correctly measures H-p(3) for beta radiations as well as photons.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 50 条
  • [1] Calibration of an eye lens dosemeter in terms of Hp(3) to be used in interventional radiology
    Borges, F. L. S.
    Guimaraes, M. C.
    Da Silva, T. A.
    Nogueira Tavares, M. S.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 45 - 47
  • [2] DEVELOPMENT OF AN ALGORITHM TO ESTIMATE EYE LENS DOSE IN TERMS OF OPERATIONAL QUANTITY Hp(3) USING HEAD TLD BADGE
    Madhumita, B.
    Sneha, C.
    Dipali, V.
    Pradhan, S. M.
    Bakshi, A. K.
    Datta, D.
    Tripathi, S. M.
    Singh, S. K.
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (04) : 364 - 373
  • [3] Evaluation of equivalent dose to eye lens through dose equivalent Hp(3)
    Marcantonini, Marta
    Chiappiniello, Andrea
    Beneventi, Sara
    Reggioli, Valentina
    Dipilato, Anna C.
    Fulcheri, Christian P. L.
    Iacco, Martina
    Zucchetti, Claudio
    Tarducci, Roberto
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 29 - 32
  • [4] Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
    Principi, Sara
    Ginjaume, Merce
    Amor Duch, Maria
    Sanchez, Roberto M.
    Fernandez, Jose M.
    Vano, Eliseo
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 79 - 83
  • [5] Characterization of small radiophotoluminescence dosemeter in terms of HP(0.07) for extremity dose monitoring of medical personnel
    Kowatari, M.
    Yoshitomi, H.
    Nagamoto, K.
    Nakagami, K.
    Moritake, T.
    Kunugita, N.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1807 - 1812
  • [6] The new EYE-D™ dosemeter for measurements of HP(3) for medical staff
    Bilski, P.
    Bordy, J-M.
    Daures, J.
    Denoziere, M.
    Fantuzzi, E.
    Ferrari, P.
    Gualdrini, G.
    Kopec, M.
    Mariotti, F.
    Monteventi, F.
    Wach, S.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1239 - 1242
  • [7] ESTIMATION OF Hp(3) TO THE EYE LENS OF INTERVENTIONAL RADIOLOGISTS-RELATION BETWEEN THE EYE LENS DOSE AND RADIOLOGIST'S HEIGHT
    Tanaka, Takuro
    Matsubara, Kosuke
    Fukuda, Atsushi
    Kobayashi, Satoshi
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (04) : 409 - 417
  • [8] INFLUENCE OF THE PHANTOM SHAPE (SLAB, CYLINDER OR ALDERSON) ON THE PERFORMANCE OF AN Hp(3) EYE DOSEMETER
    Behrens, R.
    Hupe, O.
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (04) : 441 - 449
  • [9] IRRADIATION DOSE TO THE LENS OF THE EYE DURING CT OF THE HEAD
    LUND, E
    HALABURT, H
    NEURORADIOLOGY, 1982, 22 (04) : 181 - 184
  • [10] DOSE MEASUREMENT PRECISION OF AN RPLD-BASED EYE LENS DOSEMETER APPLICABLE TO THE MEDICAL SECTOR
    Kowataril, Munehiko
    Nagamoto, Keisuke
    Nakagami, Koichi
    Yoshitomi, Hiroshi
    Moritake, Takashi
    Kunugita, Naoki
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (17) : 1303 - 1312