A comparison of the influence of three different lumbar interbody fusion approaches on stress in the pedicle screw fixation system: Finite element static and vibration analyses

被引:23
|
作者
Fan, Wei [1 ]
Guo, Li-Xin [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, 3-11 Wenhua Rd, Shenyang 110819, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
bilateral pedicle screw fixation; breakage; finite element; lumbar interbody fusion; static and vibration analyses; BIOMECHANICAL ANALYSIS; SPINE; INSTRUMENTATION; LOAD; COMPLICATIONS; STABILITY; POSTERIOR; BEHAVIOR; FAILURE; DEVICE;
D O I
10.1002/cnm.3162
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to examine breakage risk of the bilateral pedicle screw (BPS) fixation system under static and vibration loadings after three different types of lumbar interbody fusion surgery. A previously validated intact L1-sacrum finite element model was modified to simulate anterior, posterior, and transforaminal lumbar interbody fusion (ALIF, PLIF, and TLIF, respectively) with BPS fixation system (consisting of pedicle screws and rigid connecting rods) at L4-L5. As a risk parameter for breakage, the von Mises stresses in the pedicle screws and the rods for the ALIF, PLIF, and TLIF models under static loading (flexion, extension, lateral bending, and axial torsion moments) and vibration loading (sinusoidal vertical load) were calculated and compared. The calculated von Mises stresses were different in the ALIF, PLIF, and TLIF models, but these stresses for all the fusion models were found to be concentrated in neck of the pedicle screw and middle of the rod under both the static and vibration loadings. The results from static analyses showed that the maximum stress in the BPS fixation system was greater in the TLIF model than in the ALIF and PLIF models under all the applied static loadings. The results from transient dynamic analyses also showed that the TLIF generated greater dynamic responses of the stress in the BPS fixation system to the vertical vibration compared with the ALIF and PLIF. It implies that the TLIF procedure might incur a higher risk of breakage for the BPS fixation system than the ALIF and PLIF procedures.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion with Coflex-F and Pedicle Screw Fixation: Finite Element Analysis of Static and Vibration Conditions
    Zhu, Jia
    Shen, Hangkai
    Cui, Yangyang
    Fogel, Guy R.
    Liao, Zhenhua
    Liu, Weiqiang
    ORTHOPAEDIC SURGERY, 2022, 14 (09) : 2339 - 2349
  • [2] Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rods
    Wei Fan
    Li-Xin Guo
    Dan Zhao
    Journal of Materials Science: Materials in Medicine, 2019, 30
  • [3] Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rods
    Fan, Wei
    Guo, Li-Xin
    Zhao, Dan
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2019, 30 (10)
  • [4] Finite element analysis of anterior lumbar interbody fusion - Threaded cylindrical cage and pedicle screw fixation
    Kim, Young
    SPINE, 2007, 32 (23) : 2558 - 2568
  • [5] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Kyung-Chul Choi
    Kyeong-Sik Ryu
    Sang-Ho Lee
    Yeong Hyeon Kim
    Sung Jae Lee
    Chun-Kun Park
    BMC Musculoskeletal Disorders, 14
  • [6] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Choi, Kyung-Chul
    Ryu, Kyeong-Sik
    Lee, Sang-Ho
    Kim, Yeong Hyeon
    Lee, Sung Jae
    Park, Chun-Kun
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [7] Slippage reduction of lumbar spondylolisthesis using percutaneous pedicle screw with reduction fixation system after interbody fusion: A comparison with traditional open fusion and pedicle screw fixation
    Heo, Dong-Hwa
    Jang, Jae-Won
    Lee, Jung-Kil
    Park, Choon-Keun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 67 : 156 - 162
  • [8] Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study
    Ambati, Divya V.
    Wright, Edward K., Jr.
    Lehman, Ronald A., Jr.
    Kang, Daniel G.
    Wagner, Scott C.
    Dmitriev, Anton E.
    SPINE JOURNAL, 2015, 15 (08): : 1812 - 1822
  • [9] Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion
    Doulgeris, James J.
    Aghayev, Kamran
    Gonzalez-Blohm, Sabrina A.
    Lee, William E., III
    Vrionis, Frank D.
    CLINICAL BIOMECHANICS, 2015, 30 (02) : 205 - 210
  • [10] Biomechanical Comparison of Stand-Alone and Bilateral Pedicle Screw Fixation for Oblique Lumbar Interbody Fusion Surgery-A Finite Element Analysis
    Fang, Guofang
    Lin, Yunzhi
    Wu, Jiachang
    Cui, Wengang
    Zhang, Shihao
    Guo, Lili
    Sang, Hongxun
    Huang, Wenghua
    WORLD NEUROSURGERY, 2020, 141 : E204 - E212