Information Theoretic Discrepancy based Iterative Reconstruction (IDIR) Algorithm for Dual Energy X-ray Systems

被引:1
|
作者
Jang, Kwang Eun [1 ]
Lee, Jongha [1 ]
Lee, Kangui [1 ]
Sung, Younghun [1 ]
Lee, SeungDeok [1 ]
机构
[1] SAIT, Adv Media Lab, San 14, Yongin, Gyeonggi, South Korea
关键词
Information theoretic discrepancy; Dual energy computed tomography (DECT); Material decomposition; Polychromatic reconstruction; TRANSMISSION TOMOGRAPHY; VISIBLE HUMAN; MINIMIZATION; MODEL; CT;
D O I
10.1117/12.911430
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In dual energy computed tomography (DECT), two sets of projection data are acquired using a couple of independent X-ray spectra. Since the attenuation characteristic of a material without a K-edge in a typical medical X-ray spectrum range is accurately described by the linear combination of two phenomena, which are the photoelectric attenuation and the Compton scatter, the DECT is theoretically capable of separating one material from another. However, the material decomposition (MD) is still a challenging problem in DECT, since two sets of sinograms from distinct X-ray spectra are not spatially aligned in practices. To avoid this problem, the MD is often achieved by a weighted summation of two reconstructed volumes that correspond to a couple of sets of projection data, which the monochromatic approximation is generally used in the reconstruction procedure. The accuracy of the MD, therefore, can be limited due to the erroneous ignorance of the energy dependency of the acquisition model. In this paper, we propose a novel algorithm, named information theoretic discrepancy based iterative reconstruction (IDIR) algorithm, for an accurate MD in dual energy X-ray systems. The generalized information theoretic discrepancy (GID) measure is newly employed as the objective value. Using particular features of the GID, a tractable objective function for the material-selective reconstruction is derived, which accounts the exact polychromatic model of transmission tomography. Since the spectral model of measured data is explicitly considered, the accurate MD is possible even for misaligned projections. In numerical experiments, the proposed method showed superior reconstruction performance over the conventional approach.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Line Integral Alternating Minimization Algorithm for Dual-Energy X-Ray CT Image Reconstruction
    Chen, Yaqi
    O'Sullivan, Joseph A.
    Politte, David G.
    Evans, Joshua D.
    Han, Dong
    Whiting, Bruce R.
    Williamson, Jeffrey F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (02) : 685 - 698
  • [22] An iterative algorithm for X-ray CT fluoroscopy
    Wang, G
    Schweiger, G
    Vannier, MW
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) : 853 - 856
  • [23] An iterative algorithm for X-ray CT fluoroscopy
    Wang, G
    Schweiger, GD
    Vannier, MW
    RADIOLOGY, 1998, 209P : 434 - 434
  • [24] Algorithm for Optimization of the X-Ray Beam and Filter Parameters in Dual-Energy Imaging Systems
    Romadanov, I.
    Sattarivand, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E389 - E389
  • [25] An iterative reconstruction algorithm in cone beam geometry: Simulation and application in X-ray microtomography
    Zolfaghari, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (1-2): : 326 - 336
  • [26] Iterative reconstruction algorithm in cone beam geometry: simulation and application in X-ray microtomography
    Zolfaghari, Afsoun
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 378 (1-2): : 326 - 336
  • [27] Improving iterative image reconstruction for X-ray CT
    Dinis Almeida, Pedro Miguel
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (08) : 1062 - 1062
  • [28] The Information-Theoretic Limits for the Performance of X-ray Source Based Navigation (Xnav) and X-ray Communication (Xcom)
    Jablonski, Daniel G.
    PROCEEDINGS OF THE 22ND INTERNATIONAL TECHNICAL MEETING OF THE SATELLITE DIVISION OF THE INSTITUTE OF NAVIGATION (ION GNSS 2009), 2009, : 1458 - 1466
  • [29] Effects of reconstruction voxelization in iterative X-ray CT reconstruction.
    Zbijewski, W
    Beekman, FJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3205 - 3207
  • [30] Dual energy X-ray absorptiometry
    Winzenberg, Tania
    Jones, Graeme
    AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (1-2) : 43 - 44