Comparison of the HOTV and Lea symbols visual acuity tests in patients with amblyopia

被引:0
|
作者
Ruttum, MS [1 ]
Dahlgren, M [1 ]
机构
[1] Med Coll Wisconsin, Inst Eye, Milwaukee, WI 53226 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine whether the Lea symbols visual acuity test, compared with the HOTV visual acuity test, overestimates visual acuity in patients with amblyopia. Patients and Methods: Fifty-nine patients with amblyopia or a history of amblyopia treatment had visual acuity measurements in both eyes with the HOTV and Lea symbols tests. Crowding bars, separated by a width of 1 optotype, and the original pilot-testing protocol in the Amblyopia Treatment Study were used to quantify visual acuity. Results: The patients' ages ranged from 4 to 35 years (mean age, 10.1 years). Visual acuity in the amblyopic eyes ranged from 20120 to 20/250. The mean visual acuity difference (HOTV scores vs Lea symbols scores) was -0.056 logMAR units (P < .001), slightly more than half of a line. The negative value indicates that patients performed better on the HOTV test. In nonamblyopic eyes, the mean difference was -0.05 logMAR units (P < .001). Patients with strabismic amblyopia had a mean difference of -0.05 logMAR units (P = .08); those with anisometropic amblyopia had a mean difference of -0.07 logMAR units (P = .002). Patients 8 years and younger had a mean difference of -0.04 logMAR units (P = .05); those older than 8 years had a mean difference of -0.06 logMAR units (P = .002). Conclusions: In both amblyopic and nonamblyopic eyes, visual acuity measurements were better on HOTV testing compared with Lea symbols testing. The differences persisted regardless of patient age and the cause and severity of amblyopia. Overestimation of visual acuity by the Lea symbols test was not found.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [31] Comparison of visual acuity across pediatric tests
    Anstice, Nicola
    Watkins, Samantha
    Thomson, Melissa
    Thompson, Benjamin
    Jacobs, Robert J.
    Collins, Andrew
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [32] The results of visual acuity measurements conducted by Lea symbols far chart on pre-school children
    Kulikova, SV
    [J]. PERCEPTION, 1997, 26 (06) : 793 - 793
  • [33] INFLUENCE OF LUMINANCE ON VISUAL ACUITY IN AMBLYOPIA
    ALPERN, M
    FLOM, MC
    CALOROSO, E
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1969, 46 (07): : 545 - &
  • [34] Dichoptic and Monocular Visual Acuity in Amblyopia
    Birch, Eileen E.
    Jost, Reed M.
    Hudgins, Lindsey A.
    Morale, Sarah E.
    Donohoe, M. A. T. T. H. E. W.
    Kelly, Krista R.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 242 : 209 - 214
  • [35] INFLUENCE OF LUMINANCE ON VISUAL ACUITY IN AMBLYOPIA
    CALOROSO, E
    FLOM, MC
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1969, 46 (03): : 189 - &
  • [36] TESTING VISUAL-ACUITY IN AMBLYOPIA
    HAASE, W
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1987, 191 (04) : 318 - 318
  • [37] Comparison of the Amblyopia Treatment Study HOTV and the Electronic-Early Treatment of Diabetic Retinopathy Study visual acuity protocols in amblyopic children aged 5 to 11 years
    Birch, Eileen E.
    Strauber, Samara F.
    Beck, Roy W.
    Holmes, Jonathan M.
    [J]. JOURNAL OF AAPOS, 2009, 13 (01): : 75 - 78
  • [38] Validity of the Lea visual acuity chart.
    OrelBixler, DA
    Schmidt, P
    Moore, B
    Ciner, E
    Cyert, L
    Dobson, V
    Maguire, M
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 512 - 512
  • [39] The Freiburg Acuity Test in Preschool Children: Testability, Test-Retest Variability, and Comparison With LEA Symbols
    Farassat, Navid
    Jehle, Vanessa
    Heinrich, Sven P.
    Lagreze, Wolf A.
    Bach, Michael
    [J]. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (03):
  • [40] AN EVALUATION OF VISUAL-ACUITY SYMBOLS
    FINK, WH
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1945, 28 (07) : 701 - 711