EFFECTS OF AIR EXCHANGE PROPERTY OF PASSIVE-TYPE RADON-THORON DISCRIMINATIVE DETECTORS ON PERFORMANCE OF RADON AND THORON MEASUREMENTS

被引:20
|
作者
Omori, Y. [1 ]
Janik, M. [1 ]
Sorimachi, A. [2 ]
Ishikawa, T. [1 ]
Tokonami, S. [2 ]
机构
[1] Natl Inst Radiol Sci, Res Ctr Radiat Protect, Inage Ku, Chiba 2638555, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Phys, Hirosaki, Aomori 0368564, Japan
关键词
LUNG-CANCER; AREAS; RISK; NIRS;
D O I
10.1093/rpd/ncs210
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pairs of diffusion chambers with different air exchange rates are used in a large-scale survey to determine radon and thoron, separately. When they are enclosed in radon-proof bags for keeping after the exposure, since radon does not escape out immediately from the low-diffusion chamber, it leads to further exposure in the bags and disturbs the estimation of radon and thoron concentrations. In this study, the effects of the different air exchange properties of the radon thoron discriminative detectors with CR-39 chips on the estimations of radon and thoron concentrations were investigated. The commercially available and frequently used detectors, Raduet, are examined in this study. The result shows that radon escapes out in 10 h. When degassing is not enough after the exposure in a calibration experiment or high-background radiation area, the residual radon causes the overestimation of the radon concentration and increase in the uncertainty in the thoron concentration, i.e. a low-performance quality of radon and thoron measurements.
引用
收藏
页码:140 / 145
页数:6
相关论文
共 37 条
  • [31] Field Experience with Soil Gas Mapping Using Japanese Passive Radon/Thoron Discriminative Detectors for Comparing High and Low Radiation Areas in Serbia (Balkan Region)
    Zunic, Zora S.
    Janik, Miroslaw
    Tokonami, Shinji
    Veselinovic, Nenad
    Yarmoshenko, Ilia V.
    Zhukovsky, Michael
    Ishikawa, Tetsuo
    Ramola, Rakesh C.
    Ciotoli, Giancarlo
    Jovanovic, Peter
    Kozak, Krzysztof
    Mazur, Jadwiga
    Celikovic, Igor
    Ujic, Predrag
    Onischenko, Aleksandra
    Sahoo, Sarat K.
    Bochicchio, Francesco
    JOURNAL OF RADIATION RESEARCH, 2009, 50 (04) : 355 - 361
  • [32] PASSIVE ONE-ELEMENT TRACK ETCH DOSIMETER FOR SIMULTANEOUS MEASUREMENT OF RADON, THORON AND DECAY PRODUCTS IN AIR
    URBAN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 685 - 688
  • [33] Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air
    Omori, Yasutaka
    Shimo, Michikuni
    Janik, Miroslaw
    Ishikawa, Tetsuo
    Yonehara, Hidenori
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (03)
  • [34] Long-term determination of airborne radon progeny concentrations using LR 115 detectors and the effects of thoron
    Choi, V. W. Y.
    Ng, C. K. M.
    Lam, R. K. K.
    Janik, M.
    Sorimachi, A.
    Kranrod, C.
    Nikezic, D.
    Tokonami, S.
    Yu, K. N.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 404 - 407
  • [35] Calibration and optimization of a low cost diffusion chamber for passive separated measurements of radon and thoron in soil by Lexan PC SSNTD
    Amanat, B.
    Kardan, M. R.
    Faghihi, R.
    Taheri, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2014, 12 (01): : 61 - 67
  • [36] Measurement of radon and thoron concentration by using LR-115 type-II plastic track detectors in the environ of Brahmaputra Valley, Assam, India
    Deka, PC
    Sarkar, S
    Bhattacharjee, B
    Goswami, TD
    Sarma, BK
    Ramachandran, TV
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 431 - 434
  • [37] DETERMINATION OF THE SPECIFIC ACTIVITY OF ALPHA EMITTERS USING A LARGE AREA ZNS SCINTILLATION DETECTOR AND ITS APPLICATION TO QUANTITATIVE MEASUREMENTS OF RADON, THORON, AND PROGENY IN SOIL, AIR, AND WATER
    SKRABLE, KW
    PHOENIX, KA
    CHABOT, GE
    FRENCH, CS
    ALEXANDER, EL
    CASPARIUS, RE