Real-time 2D/3D registration for tumor motion tracking during radiotherapy

被引:0
|
作者
Furtado, H. [1 ]
Gendrin, C. [1 ]
Bloch, C. [1 ]
Spoerk, J. [1 ]
Pawiro, S. A. [1 ]
Weber, C. [1 ]
Figl, M. [1 ]
Stock, M. [2 ]
Georg, D. [2 ]
Bergmann, H. [1 ]
Birkfellner, W. [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Med Univ Vienna, Univ Clin Radiotherapy, Div Med Phys, Vienna, Austria
来源
基金
奥地利科学基金会;
关键词
Image guided radiation therapy; 2D/3D registration; general purpose computations on graphics hardware; CUDA; VALIDATION; PROSTATE; LUNG;
D O I
10.1117/12.910117
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Organ motion during radiotherapy is one of causes of uncertainty in dose delivery. To cope with this, the planned target volume (PTV) has to be larger than needed to guarantee full tumor irradiation. Existing methods deal with the problem by performing tumor tracking using implanted fiducial markers or magnetic sensors. In this work, we investigate the feasibility of using x-ray based real time 2D/3D registration for non-invasive tumor motion tracking during radiotherapy. Our method uses purely intensity based techniques, thus avoiding markers or fiducials. X-rays are acquired during treatment at a rate of 5.4Hz. We iteratively compare each x-ray with a set of digitally reconstructed radiographs (DRR) generated from the planning volume dataset, finding the optimal match between the x-ray and one of the DRRs. The DRRs are generated using a ray-casting algorithm, implemented using general purpose computation on graphics hardware (GPGPU) programming techniques using CUDA for greater performance. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the PTV. The phantom motion is measured with an rms error of 2.1 mm and mean registration time is 220 ms. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is seen. Mean registration time is always under 105 ms which is well suited for our purposes. These results demonstrate that real-time organ motion monitoring using image based markerless registration is feasible.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Monitoring tumor motion by real time 2D/3D registration during radiotherapy
    Gendrin, Christelle
    Furtado, Hugo
    Weber, Christoph
    Bloch, Christoph
    Figl, Michael
    Pawiro, Supriyanto Ardjo
    Bergmann, Helmar
    Stock, Markus
    Fichtinger, Gabor
    Georg, Dietmar
    Birkfellner, Wolfgang
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 102 (02) : 274 - 280
  • [2] MONITORING LUNG TUMOR MOTION BY REAL-TIME 2D/3D REGISTRATION
    Gendrin, C.
    Weber, C.
    Bloch, C.
    Stock, M.
    Georg, D.
    Figl, M.
    Bergmann, H.
    Birkfellner, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S453 - S453
  • [3] Real-time 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, Hugo
    Steiner, Elisabeth
    Stock, Markus
    Georg, Dietmar
    Birkfellner, Wolfgang
    [J]. ACTA ONCOLOGICA, 2013, 52 (07) : 1464 - 1471
  • [4] Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy
    Furtado, H.
    Steiner, E.
    Stock, M.
    Georg, D.
    Birkfellner, W.
    [J]. MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [5] Real-time 2D Video/3D LiDAR Registration
    Bodensteiner, C.
    Arens, M.
    [J]. 2012 21ST INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR 2012), 2012, : 2206 - 2209
  • [6] REAL-TIME 2D/3D REGISTRATION VIA CNN REGRESSION
    Miao, Shun
    Wang, Z. Jane
    Zheng, Yefeng
    Liao, Rui
    [J]. 2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1430 - 1434
  • [7] A CNN Regression Approach for Real-Time 2D/3D Registration
    Miao, Shun
    Wang, Z. Jane
    Liao, Rui
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (05) : 1352 - 1363
  • [8] 2D/3D registration and motion tracking for surgical interventions
    Weese, J
    Buzug, TM
    Penney, GP
    Desmedt, P
    [J]. PHILIPS JOURNAL OF RESEARCH, 1998, 51 (02) : 299 - 316
  • [9] FLIRT: a software suite for real-time 2D/3D image registration for image guided radiotherapy
    Furtado, H.
    Gendrin, C.
    Spoerk, J.
    Figl, M.
    Georg, D.
    Birkfellner, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S485 - S485
  • [10] Comparison of 2D and 3D modeled tumor motion estimation/prediction for dynamic tumor tracking during arc radiotherapy
    Liu, Wu
    Ma, Xiangyu
    Yan, Huagang
    Chen, Zhe
    Nath, Ravinder
    Li, Haiyun
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09): : N168 - N179