A High-Throughput Time-Resolved Mini-Silicon Photomultiplier With Embedded Fluorescence Lifetime Estimation in 0.13 μm CMOS

被引:75
|
作者
Tyndall, David [1 ,2 ,3 ]
Rae, Bruce R. [4 ]
Li, David Day-Uei [5 ]
Arlt, Jochen [6 ]
Johnston, Abigail [6 ]
Richardson, Justin A. [3 ]
Henderson, Robert K. [1 ,2 ]
机构
[1] Univ Edinburgh, Sch Engn, CMOS Sensors & Syst Grp, Edinburgh EH9 3JL, Midlothian, Scotland
[2] Univ Edinburgh, Sch Engn, Inst Integrated Micro & Nano Syst, Edinburgh EH9 3JL, Midlothian, Scotland
[3] Dialog Semicond, Edinburgh EH1 3DQ, Midlothian, Scotland
[4] STMicroelectronics, Edinburgh EH12 7BF, Midlothian, Scotland
[5] Univ Sussex, Sch Engn & Informat, Dept Engn & Design, Brighton BN1 9QT, E Sussex, England
[6] Univ Edinburgh, Sch Phys & Astron, COSMIC, Edinburgh EH9 3JZ, Midlothian, Scotland
基金
英国工程与自然科学研究理事会;
关键词
Biosensors; silicon photomultipliers (SiPMs); single photon avalanche diodes (SPADs); time-correlated single photon counting (TCSPC); time domain fluorescence lifetime; DOMAIN; ARRAY;
D O I
10.1109/TBCAS.2012.2222639
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a miniaturized, high-throughput, time-resolved fluorescence lifetime sensor implemented in a 0.13 mu m CMOS process, combining single photon detection, multiple channel timing and embedded pre-processing of fluorescence lifetime estimations on a single device. Detection is achieved using an array of single photon avalanche diodes (SPADs) arranged in a digital silicon photomultiplier (SiPM) architecture with 400 ps output pulses and a 10% fill-factor. An array of time-to-digital converters (TDCs) with approximate to 50 ps resolution records up to 8 photon events during each excitation period. Data from the TDC array is then processed using a centre-of-mass method (CMM) pre-calculation to produce fluorescence lifetime estimations in real-time. The sensor is believed to be the first reported implementation of embedded fluorescence lifetime estimation. The system is demonstrated in a practical laboratory environment with measurements of a variety of fluorescent dyes with different single exponential lifetimes, successfully showing the sensor's ability to overcome the classic pile-up limitation of time-correlated single photon counting (TCSPC) by over an order of magnitude.
引用
收藏
页码:562 / 570
页数:9
相关论文
共 50 条
  • [21] High-throughput monitoring of biomass conversion reaction with automatic time-resolved analysis
    Chi, Zhongmei
    Zhao, Siqi
    Feng, Yunxiang
    Yang, Li
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1646
  • [22] CellCognition: time-resolved phenotype annotation in high-throughput live cell imaging
    Held, Michael
    Schmitz, Michael H. A.
    Fischer, Bernd
    Walter, Thomas
    Neumann, Beate
    Olma, Michael H.
    Peter, Matthias
    Ellenberg, Jan
    Gerlich, Daniel W.
    NATURE METHODS, 2010, 7 (09) : 747 - U118
  • [23] Screening for SERCA Activators using a High-throughput Time-Resolved FRET Assay
    Li, Ji
    Langer, Holly
    Peterson, Kurt C.
    Muretta, Joseph M.
    Gillispie, Gregory D.
    Cornea, Razvan L.
    Thomas, David D.
    BIOPHYSICAL JOURNAL, 2013, 104 (02) : 299A - 299A
  • [24] Microfluidic chips for time-resolved high-throughput patch-clamp studies
    Olofsson, J
    Karlsson, M
    Pihl, J
    Sinclair, J
    Orwar, O
    BIOPHYSICAL JOURNAL, 2003, 84 (02) : 488A - 488A
  • [25] A 0.18-μm CMOS Array Sensor for Integrated Time-Resolved Fluorescence Detection
    Huang, Ta-chien D.
    Sorgenfrei, Sebastian
    Gong, Ping
    Levicky, Rastislav
    Shepard, Kenneth L.
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2009, 44 (05) : 1644 - 1654
  • [26] A cell-based, high-throughput homogeneous time-resolved fluorescence assay for the screening of potential κ-opioid receptor agonists
    Yue Wang
    Ming Yan
    Guang-yao Zheng
    Ling He
    Huan Yang
    Acta Pharmacologica Sinica, 2014, 35 : 957 - 966
  • [27] Development of Filtration-Based Time-Resolved Fluorescence Assay for the High-Throughput Screening of Urotensin II Receptor Antagonist
    Oh, Kwang-Seok
    Lee, Sunghou
    Lee, Byung Ho
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2011, 9 (05) : 514 - 521
  • [28] A homogeneous time-resolved fluorescence-based high-throughput screening system for discovery of inhibitors of IKKβ-NEMO interaction
    Gotoh, Yusuke
    Nagata, Hidetaka
    Kase, Hideo
    Shimonishi, Manabu
    Ido, Motoharu
    ANALYTICAL BIOCHEMISTRY, 2010, 405 (01) : 19 - 27
  • [29] A Time-Resolved CMOS Image Sensor With Draining-Only Modulation Pixels for Fluorescence Lifetime Imaging
    Li, Zhuo
    Kawahito, Shoji
    Yasutomi, Keita
    Kagawa, Keiichiro
    Ukon, Juichiro
    Hashimoto, Mamoru
    Niioka, Hirohiko
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2012, 59 (10) : 2715 - 2722
  • [30] High-throughput time-resolved morphology screening in bacteria reveals phenotypic responses to antibiotics
    Taiyeb Zahir
    Rafael Camacho
    Raffaele Vitale
    Cyril Ruckebusch
    Johan Hofkens
    Maarten Fauvart
    Jan Michiels
    Communications Biology, 2