Comparison of Two NIRS Tissue Oximeters (Moxy and Nimo) for Non-Invasive Assessment of Muscle Oxygenation and Perfusion

被引:8
|
作者
Scholkmann, Felix [1 ,2 ]
Scherer-Vrana, Andrea [3 ]
机构
[1] Univ Zurich, Univ Zurich Hosp, Dept Neonatol, Biomed Opt Res Lab, Zurich, Switzerland
[2] Scholkmann Data Anal Serv Sci Consulting & Phys E, Zurich, Switzerland
[3] Balgrist Univ Hosp, Interdisciplinary Spinal Res, Dept Chiropract Med, Zurich, Switzerland
来源
关键词
Near-infrared spectroscopy; MRS; Muscle oxygenation and perfusion; Validation;
D O I
10.1007/978-3-030-34461-0_32
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Near-infrared spectroscopy (NIRS) tissue oximeters enable non-invasive measurement of muscle oxygenation and perfusion. Several NIRS oximeters are currently available, particularly for muscle measurements. Aim: To evaluate the agreement of oxygenation and perfusion measurements obtained by two devices (Moxy, Fortiori Designs LLC, USA, and Nimo, Nirox, Italy) during an arterial occlusion test on the arm. Subject and Methods: Arterial occlusions were conducted at the arm of one individual for 10 min with 200 mmHg. Measurements were made twice a day on five different days. Both MRS devices were fixed at the arm (covering the muscles extensor carpi ulnaris, extensor digitorum, and flexor carpi ulnaris). Results: The experiment revealed that i) both devices could detect changes in muscle oxygenation and perfusion during the occlusion, but ii) the magnitudes and dynamic changes differed between the two devices. Discussion and Conclusion: Both devices had different performances with regard to the measurement of tissue oxygenation and perfusion. This study shows that it might be worthwhile to compare all NIRS tissue oximeters currently available for muscle measurement in a large systematic study to increase the comparability of measurements obtained with different devices.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 50 条
  • [41] Diagnosis of defects in oxidative muscle metabolism by non-invasive tissue oximetry
    Bank, W
    Chance, B
    [J]. MOLECULAR AND CELLULAR BIOCHEMISTRY, 1997, 174 (1-2) : 7 - 10
  • [42] Non-invasive, continous monitoring of cerebral oxygenation changes during cardiopulmonary bypass by near-infrared spectroscopy (NIRS)
    Benni, PB
    Chen, B
    Amory, D
    Li, JKJ
    [J]. PROCEEDINGS OF THE IEEE TWENTY-SECOND ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 1996, : 46 - 47
  • [43] BOLD MRI in sheep fetuses: a non-invasive method for measuring changes in tissue oxygenation
    Sorensen, A.
    Pedersen, M.
    Tietze, A.
    Ottosen, L.
    Duus, L.
    Uldbjerg, N.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (06) : 687 - 692
  • [44] Non-invasive assessment of diastolic cardiac perfusion time through acoustic cardiography
    Zuber, M.
    Erne, P.
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 : 557 - 557
  • [45] Non-invasive assessment of shunt and ventilation/perfusion ratio in neonates with pulmonary failure
    Smith, HL
    Jones, JG
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2001, 85 (02): : F127 - F132
  • [46] NON-INVASIVE ASSESSMENT OF MYOCARDIAL PERFUSION IN MASKED AND WHITE-COAT HYPERTENSION
    Anyfanti, P.
    Gkaliagkousi, E.
    Triantafyllou, A.
    Dipla, K.
    Koletsos, N.
    Zarifis, H.
    Arseniou, P.
    Lazaridis, A.
    Nikolaidou, B.
    Douma, S.
    [J]. JOURNAL OF HYPERTENSION, 2019, 37 : E114 - E114
  • [47] Characterization of the Non-Invasive Assessment of the Cutaneous Microcirculation by Laser Doppler Perfusion Scanner
    Keymel, Stefanie
    Sichwardt, Julia
    Balzer, Jan
    Stegemann, Emilia
    Rassaf, Tienush
    Kleinbongard, Petra
    Kelm, Malte
    Heiss, Christian
    Lauer, Thomas
    [J]. MICROCIRCULATION, 2010, 17 (05) : 358 - 366
  • [48] DIFFERENCES IN LIVER AND KIDNEY PHYSIOLOGY MEASURED WITH NON INVASIVE (MRI) ASSESSMENT OF TISSUE OXYGENATION AND ORGAN PERFUSION IN BRAIN DEAD RATS
    Rebolledo, Rolando
    Van Erp, Anne
    Laustsen, Christoffer
    Norregaard, Rikke
    Pedersen, Michael
    Leuvenink, Henri
    Jespersen, Bente
    [J]. TRANSPLANT INTERNATIONAL, 2015, 28 : 149 - 149
  • [49] Comparison of Local Adipose Tissue Content and SRS-Derived NIRS Muscle Oxygenation Measurements in 90 Individuals
    Cooper, Chris E.
    Penfold, Stacey-Marie
    Elwell, Clare E.
    Angus, Caroline
    [J]. OXYGEN TRANSPORT TO TISSUE XXXI, 2010, 662 : 177 - 181
  • [50] NON-INVASIVE MEASURE OF TISSUE PERFUSION, SMO2, COMPARED WITH STANDARD INVASIVE ASSESSMENTS OF SHOCK
    May, Erin Bohula
    Soller, Babs
    O'Brien, Molly
    Kidd, Stephen
    Berg, David
    O'Malley, Ryan
    Morrow, David
    Wiviott, Stephen
    [J]. CRITICAL CARE MEDICINE, 2014, 42 (12)