Age-Related Decrease of the Retinal Vasculature Area Identified with a Novel Computer-Aided Analysis System

被引:5
|
作者
Yamamoto, Yuuka [2 ]
Yamamoto, Yoichiro [3 ,4 ]
Marugame, Atsushi [5 ]
Ogura, Maki [5 ]
Saito, Akira [5 ]
Ohta, Kouichi [6 ]
Fukumoto, Manabu [1 ]
Murata, Toshinori [2 ]
机构
[1] Tohoku Univ, Inst Dev Aging & Canc, Dept Pathol, Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Shinshu Univ, Sch Med, Dept Ophthalmol, Matsumoto, Nagano 390, Japan
[3] Nippon Med Coll Hosp, Div Diagnost Pathol, Tokyo, Japan
[4] Mayo Clin, Dept Mol Med, Rochester, MN USA
[5] NEC Corp Ltd, Med Solut Div, Tokyo, Japan
[6] Matsumoto Dent Univ, Dept Ophthalmol, Nagano, Japan
来源
关键词
age; arteriosclerosis; computer-aided diagnosis; hypertension; retinal microvasculature; MICROVASCULAR ABNORMALITIES; ATHEROSCLEROSIS RISK; VESSEL DIAMETERS; OLDER POPULATION; VEIN OCCLUSION; HYPERTENSION; PHOTOGRAPHY; SIGNS; COMMUNITIES; RETINOPATHY;
D O I
10.1620/tjem.228.229
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fundus photographs enable non-invasive analysis of the status of the microcirculation by directly observing the retinal vasculature. Retinal microvascular abnormalities are important clinical markers of hypertension and arteriosclerosis, but retinal microvascular changes can be observed in older individuals without hypertension. In this study, our goal is to elucidate the effects of aging on fundus vessels in the retinal photograph. We analyzed retinal vessels of 161 healthy volunteers (49.5 +/- 18.7 years, range 18-87) using in-house computer-aided measurement system to measure areas and diameters of all retinal vessels across the entire area of a retinal photograph. The vessels were segmented according to color, and then their area, size, length and thickness were measured by image processing. We also analyzed the correlation between total blood vessel area, age and mean arterial blood pressure (MABP). The decrease in total blood vessel area was dependent on both age and MABP. Moreover, decrease in blood vessel area was also correlated with age for the normotensive group. Furthermore, the slope of the regression line for retinal vessel area with MABP was significantly higher in participants aged <= 60 years than in those aged over 60 years. Changes in retinal vessel area with aging were observed in both arterioles and venules. In conclusion, we found the significant decrease in retinal vessel area that is correlated well with calendar age. Therefore, we need to carefully apply traditional classifications of fundus examination for hypertensive retinopathy in older individuals.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 50 条
  • [31] A computer-aided diagnostic system for intestinal polyps identified by wireless capsule endoscopy
    Constantinescu, Adriana Florentina
    Ionescu, Mihaela
    Iovanescu, Vlad-Florin
    Ciurea, Marius Eugen
    Ionescu, Alin Gabriel
    Streba, Costin Teodor
    Bunescu, Marius-Gabriel
    Rogoveanu, Ion
    Vere, Cristin Constantin
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (03): : 979 - 984
  • [32] A COMPUTER-AIDED SYSTEM IN THE USE OF A DATA-ANALYSIS SYSTEM
    DEMONCHAUX, E
    QUINQUETON, J
    RALAMBONDRAINY, H
    RAIRO-AUTOMATIQUE-SYSTEMS ANALYSIS AND CONTROL, 1984, 18 (04): : 431 - 439
  • [33] Accuracy analysis of superimposition on a virtual retinal display in computer-aided surgery
    Suthau, T
    Hellwich, O
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 1293 - 1293
  • [34] COMPUTER-AIDED ANALYSIS OF AN IMPULSE VOLTAGE MEASURING SYSTEM
    RICHARDS.AV
    RYAN, HM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1804 - 1805
  • [35] COMPUTER-AIDED MATHEMATICAL ANALYSIS OF FLUID POWER SYSTEM
    UNRUH, D
    DESIGN NEWS, 1971, 26 (07) : 132 - &
  • [36] A handheld computer-aided diagnosis system and simulated analysis
    Su, Mingjian
    Zhang, Xuejun
    Liu, Brent
    Su, Kening
    Louie, Ryan
    MEDICAL IMAGING 2016: PACS AND IMAGING INFORMATICS: NEXT GENERATION AND INNOVATIONS, 2016, 9789
  • [37] Study on computer-aided reliability design and analysis system
    Zhao, Tingdi
    Zeng, Shengkui
    Kang, Rui
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2000, 21 (03): : 206 - 209
  • [38] System of Computer-aided Analysis of Electronic Circuits.
    Baraboshkin, V.S.
    Buntov, V.D.
    Filimonov, V.I.
    Chernov, V.P.
    Trudy LPI, 1982, (381): : 42 - 44
  • [39] Computer-aided system of microscopic analysis of specimens on slides
    Sukhoverov, VS
    JOURNAL OF COMPUTER AND SYSTEMS SCIENCES INTERNATIONAL, 2000, 39 (06) : 1004 - 1007
  • [40] A COMPUTER-AIDED SYSTEM FOR SUSTAINABILITY ANALYSIS FOR THE DIECASTING PROCESS
    Singh, Princepal
    Madan, Jatinder
    Singh, Amrik
    Mani, Mahesh
    PROCEEDINGS OF THE ASME INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2012, 2012, : 1087 - 1096