Characteristics of long-pulse negative-ion source in the neutral beam injector of Large Helical Device

被引:3
|
作者
Takeiri, Y [1 ]
Ikeda, K [1 ]
Oka, Y [1 ]
Tsumori, K [1 ]
Osakabe, M [1 ]
Nagaoka, K [1 ]
Kaneko, O [1 ]
Asano, E [1 ]
Kondo, T [1 ]
Sato, M [1 ]
Shibuya, M [1 ]
Komada, S [1 ]
机构
[1] Natl Inst Fus Sci, Toki 5098292, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 03期
关键词
D O I
10.1063/1.2166675
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The injection duration has been extended beyond 100 s with a high-power hydrogen negative-ion source in a negative-ion-based neutral beam injector of the Large Helical Device superconducting fusion machine. The ion source is a cesium-seeded source with a thermally insulated plasma grid (PG), and optimized for a short-pulse operation of 2-3 s. The negative-ion production efficiency is strongly dependent on the PG temperature, and in the long-pulse operation it exceeds an appropriate temperature range of 200-300 degrees C, at which the optimum cesium coverage is formed on the PG surface. By making the PG temperature rise slower with a reduced arc power, the injection duration was extended to 110 s with an injection power of 110 kW. To extend the injection duration further with a higher injection power, stainless-steel cooling tubes have been mechanically attached to the PG for suppression of the PG temperature rise in the long-pulse operation. As a result, a long-pulse injection with an injection power of 200 kW was extended to 128 s until it was manually stopped due to the plasma collapse. However, the beam duration could be limited to around 3 min because the PG temperature rise was not saturated due to a low thermal conductivity with the thickness of the stainless-steel tube determined so that the short-pulse operation is also possible. On the other hand, the longitudinal beam distribution in a grid area of 25 x 125 cm(2) is observed to be more uniform than that with the uncooled PG. The temperature distribution of the individual grid parts becomes more uniform with the cooled PG, which should contribute to the improvement of the beam uniformity. (c) 2006 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Static performance prediction of long-pulse negative ion based neutral beam injection experiment
    Li, Yang
    Hu, Chundong
    Zhao, Yuanzhe
    Gu, Yu
    Cui, Qinglong
    Xie, Yahong
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2024, 66 (06)
  • [22] Key issues for the filament-arc ion source of EAST neutral beam injector toward high-power and long-pulse operation
    Wei, Jianglong
    Xie, Yahong
    Liu, Sheng
    Liu, Zhimin
    Liang, Lizhen
    Jiang, Caichao
    Tao, Ling
    Xu, Yongjian
    Li, Jun
    Gu, Yuming
    Xie, Yuanlai
    Hu, Chundong
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 2020, 62 (02)
  • [23] Design of the Prototype Negative Ion Source for Neutral Beam Injector at ASIPP
    Wei Jianglong
    Xie Yahong
    Liang Lizhen
    Gu Yuming
    Yi Wei
    Li Jun
    Hu Chundong
    Xie Yuanlai
    Jiang Caichao
    Tao Ling
    Sheng Peng
    Xu Yongjian
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2016, 18 (09): : 954 - 959
  • [24] Design of the Prototype Negative Ion Source for Neutral Beam Injector at ASIPP
    韦江龙
    谢亚红
    梁立振
    顾玉明
    邑伟
    李军
    胡纯栋
    谢远来
    蒋才超
    陶玲
    盛鹏
    许永建
    [J]. Plasma Science and Technology, 2016, 18 (09) : 954 - 959
  • [25] Negative hydrogen ion source for TOKAMAK neutral beam injector (invited)
    Okumura, Y
    Fujiwara, Y
    Kashiwagi, M
    Kitagawa, T
    Miyamoto, K
    Morishita, T
    Hanada, M
    Takayanagi, T
    Taniguchi, M
    Watanabe, K
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1219 - 1224
  • [26] IMPROVEMENT OF THE LARGE CURRENT NEGATIVE HYDROGEN-ION SOURCE FOR NEUTRAL INJECTION IN THE LARGE HELICAL DEVICE
    TSUMORI, K
    ANDO, A
    OKUYAMA, T
    SUZUKI, Y
    KANEKO, O
    OKA, Y
    TAKEIRI, Y
    AKIYAMA, R
    KAWAMOTO, T
    SEKO, K
    KURODA, T
    [J]. FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 473 - 483
  • [27] DEVELOPMENT OF A LONG PULSE PENNING TYPE NEGATIVE-ION SOURCE
    DAGENHART, WK
    STIRLING, WL
    TSAI, CC
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 805 - 805
  • [28] Development of a rf negative-ion source for ITER neutral beam injection
    McNeely, P
    Falter, HD
    Fantz, U
    Franzen, P
    Fröschle, M
    Heinemann, B
    Kraus, W
    Martens, C
    Riedl, R
    Speth, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [29] High-power negative ion sources for neutral beam injectors in Large Helical Device
    Takeiri, Y.
    Kaneko, O.
    Tsumori, K.
    Fantz, U.
    Ikeda, K.
    Nagaoka, K.
    Osakabe, M.
    Oka, Y.
    Asano, E.
    Kondo, T.
    Sato, M.
    Shibuya, M.
    Komada, S.
    [J]. PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2007, 925 : 211 - +
  • [30] Modeling activities on the negative-ion-based Neutral Beam Injectors of the Large Helical Device
    Agostinetti, P.
    Antoni, V.
    Cavenago, M.
    Chitarin, G.
    Nakano, H.
    Pilan, N.
    Serianni, G.
    Veltri, P.
    Takeiri, Y.
    Tsumori, K.
    [J]. SECOND INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES, 2011, 1390