Thermodynamic performance analysis of a R245fa organic Rankine cycle (ORC) with different kinds of heat sources at evaporator

被引:45
|
作者
Kong, Rithy [1 ,2 ]
Deethayat, Thoranis [3 ]
Asanakham, Attakorn [3 ]
Vorayos, Nat [3 ]
Kiatsiriroat, Tanongkiat [3 ]
机构
[1] Chiang Mai Univ, Fac Engn, Energy Engn Program, Chiang Mai, Thailand
[2] Chiang Mai Univ, Grad Sch, Chiang Mai, Thailand
[3] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Thermal Syst Res Lab, Chiang Mai, Thailand
关键词
Organic Rankine cycle; Thermodynamic analyses; Thermal performance; Hot water/saturated steam heat source; ZEOTROPIC MIXTURES; WORKING FLUIDS; OPTIMIZATION; EXCHANGER;
D O I
10.1016/j.csite.2018.100385
中图分类号
O414.1 [热力学];
学科分类号
摘要
The first and the second law analyses of a 20 kW(e)R245fa organic Rankine cycle (ORC) with low grade temperature heat sources were numerically studied. There were three different heat sources such as hot water, saturated steam, and combined hot water/saturated steam used to supply heat at the ORC evaporator. The heat source temperature was varied in a range of 80-110 degrees C and the pinch temperature difference between the heat source temperature and the evaporating temperature was in a range of 1-10 degrees C. The ORC condensing temperature was kept constant at 40 degrees C. The results revealed that the combined hot water/saturated steam heat source provided a highest second law or exergy efficiency due to less irreversibility generated at the evaporator followed by the saturated steam and the hot water heat sources, respectively. The increase of heat source temperature at a specific pinch could increase the second law efficiency of the cycle. However, the increase of pinch value resulted in lower second law efficiency. In addition, for the below pinch zone, with the hot water/saturated steam heat source, the reduction of the hot water flow rate slightly enhanced the ORC second law efficiency as the exergy destruction below pinch was reduced. However, there was a limit that the flow rate should not be reduced below a specific value otherwise a very high heat exchanger area was needed.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Thermo-Economic Performance Analysis of a Novel Organic Flash Rankine Cycle Using R600/R245fa Mixtures
    Fu, Guangbiao
    Zhang, Songyuan
    Ge, Zhong
    Li, Jian
    Xu, Jian
    Xie, Jianbin
    Xie, Zhiyong
    Yao, Dong
    Zhao, Tao
    Wang, Zhijie
    Yue, Shuaikun
    Zhao, Siyu
    Liu, Fanhan
    Jiang, Qiuping
    [J]. ENERGIES, 2022, 15 (21)
  • [22] Performance analysis of a supersonic ejector cycle working with R245fa
    Mazzelli, Federico
    Milazzo, Adriano
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 79 - 92
  • [23] Contribution of Metal-Organic-Heat Carrier nanoparticles in a R245fa low-grade heat recovery Organic Rankine Cycle
    Cavazzini, G.
    Bari, S.
    McGrail, P.
    Benedetti, V.
    Pavesi, G.
    Ardizzon, G.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 199
  • [24] Performance evaluation of a low-temperature solar Rankine cycle system utilizing R245fa
    Wang, X. D.
    Zhao, L.
    Wang, J. L.
    Zhang, W. Z.
    Zhao, X. Z.
    Wu, W.
    [J]. SOLAR ENERGY, 2010, 84 (03) : 353 - 364
  • [25] Experimental study of a 1 kw organic Rankine cycle with a zeotropic mixture of R245fa/R134a
    Abadi, Gholamreza Bamorovat
    Yun, Eunkoo
    Kim, Kyung Chun
    [J]. ENERGY, 2015, 93 : 2363 - 2373
  • [26] Economic Analysis of Organic Rankine Cycle Using R123 and R245fa as Working Fluids and a Demonstration Project Report
    Zhang, Xinxin
    Cao, Min
    Yang, Xiaoyu
    Guo, Hang
    Wang, Jingfu
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (02):
  • [27] Experimental study and energy loss analysis of an R245fa organic Rankine cycle prototype system with a radial piston expander
    Han, Yongqiang
    Zhang, Yiming
    Zuo, Teng
    Chen, Ruolong
    Xu, Yun
    [J]. APPLIED THERMAL ENGINEERING, 2020, 169
  • [28] Investigation of low-GWP working fluids as substitutes for R245fa in organic Rankine cycle application
    Yang, Min-Hsiung
    Liu, Ming-Chuan
    Yeh, Rong-Hua
    [J]. HELIYON, 2024, 10 (14)
  • [29] Comparison of the Utilization of 110 °C and 120 °C Heat Sources in a Geothermal Energy System Using Organic Rankine Cycle (ORC) with R245fa, R123, and Mixed-Ratio Fluids as Working Fluids
    Surindra, Mochamad Denny
    Caesarendra, Wahyu
    Prasetyo, Totok
    Mahlia, Teuku Meurah Indra
    Taufik
    [J]. PROCESSES, 2019, 7 (02):
  • [30] Isothermal Organic Rankine Cycle (ORC) driving Reverse Osmosis (RO) desalination: Experimental investigation and case study using R245fa working fluid
    Igobo, O. N.
    Davies, P. A.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 136 : 740 - 746