Detection of Breast Cancer in Automated 3D Breast Ultrasound

被引:2
|
作者
Tan, Tao [1 ]
Platel, Bram [2 ]
Mus, Roel [1 ]
Karssemeijer, Nico [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, Nijmegen, Netherlands
[2] Fraunhofer MEVIS, Bremen, Germany
关键词
automated 3D breast ultrasound; breast cancer; CAD; 3-DIMENSIONAL ULTRASOUND; MASSES;
D O I
10.1117/12.911068
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Automated 3D breast ultrasound (ABUS) is a novel imaging modality, in which motorized scans of the breasts are made with a wide transducer through a membrane under modest compression. The technology has gained high interest and may become widely used in screening of dense breasts, where sensitivity of mammography is poor. ABUS has a high sensitivity for detecting solid breast lesions. However, reading ABUS images is time consuming, and subtle abnormalities may be missed. Therefore, we are developing a computer aided detection (CAD) system to help reduce reading time and errors. In the multi-stage system we propose, segmentations of the breast and nipple are performed, providing landmarks for the detection algorithm. Subsequently, voxel features characterizing coronal spiculation patterns, blobness, contrast, and locations with respect to landmarks are extracted. Using an ensemble of classifiers, a likelihood map indicating potential malignancies is computed. Local maxima in the likelihood map are determined using a local maxima detector and form a set of candidate lesions in each view. These candidates are further processed in a second detection stage, which includes region segmentation, feature extraction and a final classification. Region segmentation is performed using a 3D spiral-scanning dynamic programming method. Region features include descriptors of shape, acoustic behavior and texture. Performance was determined using a 78-patient dataset with 93 images, including 50 malignant lesions. We used 10-fold cross-validation. Using FROC analysis we found that the system obtains a lesion sensitivity of 60% and 70% at 2 and 4 false positives per image respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Combination of digital mammography with semi-automated 3D breast ultrasound
    Kapur, A
    Carson, PL
    Eberhard, J
    Goodsitt, MM
    Thomenius, K
    Lokhandwalla, M
    Buckley, D
    Roubidoux, MA
    Helvie, MA
    Booi, RC
    LeCarpentier, GL
    Erkamp, RQ
    Chan, HP
    Fowlkes, JB
    Thomas, JA
    Landberg, CE
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (04) : 325 - 334
  • [32] Developing QA and QC protocols for 3D automated breast ultrasound (ABUS)
    Moreno, Clara Marquez
    Payne, Nicholas
    Morrish, Oliver
    Gilbert, Fiona
    BREAST CANCER RESEARCH, 2023, 25
  • [33] Analysis of 107 breast lesions with automated 3D ultrasound and comparison with mammography and manual ultrasound
    Kotsianos-Hermle, D.
    Hiltawsky, K. M.
    Wirth, S.
    Fischer, T.
    Friese, K.
    Reiser, M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) : 109 - 115
  • [34] HIGH-RESOLUTION DEDICATED 3D AUTOMATED BREAST ULTRASOUND WITH COMPLEMENTARY IMAGING FOR POINT-OF-CARE BREAST CANCER SCREENING
    Park, Claire
    Trumpour, Tiana
    Bax, Jeffrey
    Gyacskov, Igor
    Tessier, David
    Gardi, Lori
    Fenster, Aaron
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S40 - S41
  • [35] Validation of radiologists' findings by computer-aided detection (CAD) software in breast cancer detection with automated 3D breast ultrasound: a concept study in implementation of artificial intelligence software
    van Zelst, Jan C. M.
    Tan, Tao
    Mann, Ritse M.
    Karssemeijer, Nico
    ACTA RADIOLOGICA, 2020, 61 (03) : 312 - 320
  • [36] 3D Ultrasound Elastographic Imaging and Characterization of Breast Cancer In Vivo
    Sayed, Ahmed
    Abraham, Jame
    Layne, Ginger
    Mukdadi, Osama
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY, 2013, : 941 - 951
  • [37] Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts
    Drukker, Karen
    Sennett, Charlene A.
    Giger, Maryellen L.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [38] 3D ultrasound in core breast biopsy
    Lell, M
    Wenkel, E
    Aichinger, U
    Schulz-Wendtland, R
    Bautz, W
    ULTRASCHALL IN DER MEDIZIN, 2004, 25 (02): : 126 - 130
  • [39] Computer aided detection in automated 3-D breast ultrasound images: a survey
    Kozegar, Ehsan
    Soryani, Mohsen
    Behnam, Hamid
    Salamati, Masoumeh
    Tan, Tao
    ARTIFICIAL INTELLIGENCE REVIEW, 2020, 53 (03) : 1919 - 1941
  • [40] Computer aided detection in automated 3-D breast ultrasound images: a survey
    Ehsan Kozegar
    Mohsen Soryani
    Hamid Behnam
    Masoumeh Salamati
    Tao Tan
    Artificial Intelligence Review, 2020, 53 : 1919 - 1941