Evaluation of Quantification of HIV-1 RNA Viral Load in Plasma and Dried Blood Spots by Use of the Semiautomated Cobas Amplicor Assay and the Fully Automated Cobas Ampliprep/TaqMan Assay, Version 2.0, in Kisumu, Kenya

被引:21
|
作者
Ouma, Kenneth N. [1 ]
Basavaraju, Sridhar V. [2 ]
Okonji, Jully A. [1 ]
Williamson, John [3 ]
Thomas, Timothy K. [3 ]
Mills, Lisa A. [3 ]
Nkengasong, John N. [4 ]
Zeh, Clement [3 ]
机构
[1] Kenya Govt Med Res Ctr, Ctr Global Hlth Res, Kisumu, Kenya
[2] Ctr Dis Control & Prevent, HIV Prevent Branch, Div Global HIV AIDS, Ctr Global Hlth, Atlanta, GA USA
[3] Ctr Dis Control & Prevent, Div HIV AIDS Prevent, Kisumu, Kenya
[4] Ctr Dis Control & Prevent, Int Lab Branch, Div Global HIV AIDS, Ctr Global Hlth, Atlanta, GA USA
关键词
VIRUS TYPE-1 RNA; TAQMAN HIV-1; ANTIRETROVIRAL THERAPY; DIAGNOSIS; QUANTITATION; PERFORMANCE; INFECTION; SENSITIVITY;
D O I
10.1128/JCM.03048-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specificity, negative and positive predictive values (NPV and PPV, respectively), concordance, and agreement between HIV-1 viral load measurements using plasma and DBS specimens obtained from 512 HIV-1-infected pregnant females enrolled in the Kisumu Breastfeeding Study and tested with the Cobas Amplicor and CAP/CTM assays. The sensitivity and NPV of viral load detection in DBS specimens were higher with CAP/CTM (sensitivity, 100%; 95% confidence interval [CI], 99.1 to 100.0%; NPV, 100%; 95% CI, 59.0 to 100.0%) than the Cobas Amplicor (sensitivity, 96.6%; 95% CI, 94.3 to 98.1%; NPV, 58.8%; 95% CI, 40.7 to 75.4%). The PPVs were comparable between both assays when using DBS. The specificity of viral load detection in DBS specimens was lower with CAP/CTM (77.8%; 95% CI, 40.0 to 97.2%) than that of the Cobas Amplicor (95.2%; 95% CI, 76.2 to 99.9%). Good concordance and agreement were observed when paired plasma and DBS specimens were tested with both assays. Lower specificity with the CAP/CTM is likely due to proviral HIV-1 DNA amplification and lower detection limits with RT-PCR. However, the CAP/CTM has better sensitivity and higher throughput than the Cobas Amplicor. These findings suggest that DBS may be a suitable alternative to plasma when using RT-PCR, which could increase access to viral load monitoring in resource-limited settings.
引用
收藏
页码:1208 / 1218
页数:11
相关论文
共 50 条
  • [1] A field evaluation of HIV-1 RNA viral load in plasma and dried blood spots using the COBAS Amplicor Analyzer and the Nucleic Acid Extraction COBAS Ampliprep/Taqman in Kisumu, Kenya
    Ouma, K.
    Basavaraju, S.
    Okonji, J.
    Williamson, J.
    Mills, L.
    Zeh, C.
    [J]. JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2012, 15 : 37 - 38
  • [2] Improved Performance of COBAS AmpliPrep/COBAS TaqMan Version 2.0 Assay Over Amplicor Monitor Version 1.5 in the Quantification of HIV-1 RNA Viral Load in Abuja, Nigeria
    Abubakar, Ado
    Ndembi, Nicaise
    Ogbanufe, Obinna
    Inalegwu, Auchi
    Wilson, Simi
    Ebagua, Irene
    Peters, Sam
    Chime, Chris
    Dakum, Patrick
    Abimiku, Alash'le G.
    [J]. CURRENT HIV RESEARCH, 2015, 13 (04) : 262 - 267
  • [3] Evaluation of the use of plasma preparation tubes for HIV viral load testing on the COBAS AmpliPrep/COBAS TaqMan HIV-1 version 2.0
    Goedhals, Dominique
    Scott, Lesley E.
    Moretti, Serena
    Cooper, Mark A.
    Opperman, Willem J. L.
    Rossouw, Inez
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2013, 187 (02) : 248 - 250
  • [4] Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay
    Andreotti, Mauro
    Pirillo, Maria
    Guidotti, Giovanni
    Ceffa, Susanna
    Paturzo, Giovanna
    Germano, Paola
    Luhanga, Richard
    Chimwaza, David
    Mancini, Maria Grazia
    Marazzi, Maria Cristina
    Vella, Stefano
    Palombi, Leonardo
    Giuliano, Marina
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2010, 47 (01) : 4 - 7
  • [5] Upgraded Cobas Ampliprep-Cobas TaqMan Version 2.0 HIV-1 RNA Quantification Assay versus First Version: Correction of Underestimations
    Wirden, M.
    Tubiana, R.
    Fourati, S.
    Thevenin, M.
    Simon, A.
    Canestri, A.
    Ait-Arkoub, Z.
    Soulie, C.
    Marcelin, A. G.
    Katlama, C.
    Calvez, V.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2700 - 2702
  • [6] Validation of Cobas AmpliPrep/Cobas TaqMan HIV-1 Test on dried blood spots
    Ruiz, N.
    Perez, M.
    Diaz, H.
    Izquierdo, M.
    Blanco, M.
    Machado, L.
    Silva, E.
    [J]. JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2012, 15 : 107 - 107
  • [7] Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya
    Zeh, Clement
    Ndiege, Kenneth
    Inzaule, Seth
    Achieng, Rebecca
    Williamson, John
    Chang, Joy Chih-Wei
    Ellenberger, Dennis
    Nkengasong, John
    [J]. PLOS ONE, 2017, 12 (06):
  • [8] Perfomance evaluation of the new Roche Cobas ampliprep Cobas Taqman HIV-1 test version 2.0 for the quantification of HIV-1 RNA
    Pas, S. D.
    Petterson, A.
    Mes, T.
    Rossen, J.
    Schutten, M.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S11 - S11
  • [9] Performance and Evaluation of the COBAS® AmpliPrep/COBAS® TaqMan® HIV-1 Test, Version 2.0
    Schutzbank, T. E.
    Light, A.
    Palmero, M.
    Blanford, C.
    Michel-Treil, V.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2009, 11 (06): : 634 - 634
  • [10] Rapid quantification of HIV using the Cepheid HIV-1 Viral Load Assay: A comparison with COBAS AmpliPrep/COBAS TaqMan HIV Test®
    Rahamat-Langendoen, J.
    Kuijpers, J.
    Melchers, W. J. G.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S99 - S99