Behavior of Pultruded Glass-Fiber-Reinforced Polymer Beam-Columns Infilled with Engineered Cementitious Composites under Cyclic Loading

被引:24
|
作者
Chinnasamy, Yoganantham [1 ]
Joanna, Philip Saratha [2 ]
Kothanda, Karthikeyan [3 ]
Gurupatham, Beulah Gnana Ananthi [4 ]
Roy, Krishanu [5 ]
机构
[1] Hindustan Inst Technol & Sci, Sch Planning Architecture & Design Excellence, Chennai 603103, Tamil Nadu, India
[2] Hindustan Inst Technol & Sci, Dept Civil Engn, Chennai 603103, Tamil Nadu, India
[3] Vellore Inst Technol, Sch Civil Engn, Chennai 600127, Tamil Nadu, India
[4] Anna Univ, Dept Civil Engn, Coll Engn, Guindy Campus, Chennai 600025, Tamil Nadu, India
[5] Univ Waikato, Sch Engn, Hamilton 3216, New Zealand
来源
JOURNAL OF COMPOSITES SCIENCE | 2022年 / 6卷 / 11期
关键词
pultruded glass-fiber-reinforced polymer; engineered cementitious composite; high-volume fly ash; finite element analysis; cyclic loading; MECHANICAL-PROPERTIES; FLY-ASH; STRENGTH; MEMBERS;
D O I
10.3390/jcs6110338
中图分类号
TB33 [复合材料];
学科分类号
摘要
Glass-fiber-reinforced polymer (GFRP) is an advanced material that has superior corrosion resistance, a high strength-to-weight ratio, low thermal conductivity, high stiffness, high fatigue strength, and the ability to resist chemical and microbiological compounds. Despite their many advantages compared with traditional materials, GFRP sections exhibit brittle behavior when subjected to severe loading conditions such as earthquakes, which could be overcome by infilling the GFRP sections with concrete. This paper presents the results of an experimental investigation carried out on the cyclic response of a GFRP beam-column infilled with high-volume fly ash engineered cementitious composites (HVFA-ECC) consisting of 60%, 70%, and 80% fly ash as a replacement for cement. Finite element analysis was also conducted using robot structural analysis software, and the results were compared with the experimental results. The mechanical properties of GFRP sections presented are the compressive strength of ECC, the direct tensile strength of ECC determined using a dog-bone-shaped ECC specimen, the hysteresis behavior of the beam-column, and the energy dissipation characteristics. The lateral load-carrying capacity of beam-column GFRP infilled with HVFA-ECC consisting of 60%, 70%, and 80% fly ash was found to be, respectively, 43%, 31%, and 20% higher than the capacity of GFRP beam-columns without any infill. Hence the GFRP sections infilled with HVFA-ECC could be used as lightweight structural components in buildings to be constructed in earthquake-prone areas. Also in the structural components, as 70% of cement could be replaced with fly ash, it can potentially lead to sustainable construction.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Experimental Behavior of Glass Fiber-Reinforced Polymer-Reinforced Concrete Columns under Lateral Cyclic Load
    Elshamandy, Mohammed G.
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2018, 115 (02) : 337 - 349
  • [22] Bond behavior of glass fiber reinforced polymer bars with varying confinement levels under cyclic loading
    Gao, Kui
    Huang, Xiangguo
    Meng, Xin
    Gao, Jinsong
    Xu, Tao
    Cai, Tongxing
    Wu, Zhifeng
    Fan, Jian
    Li, Zhiyong
    JOURNAL OF BUILDING ENGINEERING, 2023, 77
  • [23] Bonding behavior between glass fiber reinforced polymer composite bars and engineered cementitious composite
    Wu L.
    Wang Y.
    Xie L.
    Hu C.
    Sheng D.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2020, 37 (03): : 696 - 706
  • [24] Structural Performance of Polymer Fiber Reinforced Engineered Cementitious Composites Subjected to Static and Fatigue Flexural Loading
    Sherir, Mohamed A. A.
    Hossain, Khandaker M. A.
    Lachemi, Mohamed
    POLYMERS, 2015, 7 (07) : 1299 - 1330
  • [25] Investigation of mechanical behavior of RC columns strengthened with glass fiber-reinforced polymer under eccentric loading
    Lab. of Coastal and Offshore Eng., Dalian Univ. of Technol., Dalian 116023, China
    1600, 87-93 (October 2004):
  • [26] Effect of splitting bond on shear response of reinforced engineered cementitious composite short columns under cyclic loading
    Zhang, Yangxi
    Li, Tong
    Deng, Mingke
    ENGINEERING STRUCTURES, 2022, 251
  • [27] Modeling of shear-critical reinforced engineered cementitious composites members under reversed cyclic loading
    Wu, Chang
    Pan, Zuanfeng
    Mo, Yi Lung
    Li, Mo
    Meng, Shaoping
    STRUCTURAL CONCRETE, 2018, 19 (06) : 1689 - 1701
  • [28] Short vs. long column behavior of pultruded glass-fiber reinforced polymer composites
    Hashem, ZA
    Yuan, RL
    CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (08) : 369 - 378
  • [29] Behavior of Reinforced Concrete Columns with Hybrid Reinforcement (Steel/Glass Fiber-Reinforced Polymer) under Reversed Cyclic Load
    Prajapati, Girish Narayan
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2022, 119 (04) : 141 - 155
  • [30] A fundamental study on inelastic behavior of h-section steel beam-columns under cyclic loading
    Ma, Xiang
    Usami, Tsutomu
    Ge, Hanbin
    Doboku Gakkai Ronbunshuu A, 2007, 63 (04) : 673 - 684