Performance of Low GWP Refrigerant R-516A in an Air-Cooled Chiller

被引:0
|
作者
Schultz, Kenneth [1 ]
Perez-Blanco, Marcos [1 ]
机构
[1] Ingersoll Rand, Modeling & Simulat Network Excellence, La Crosse, WI 54601 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Many HFC refrigerants have a high global warming potential (GWP), and therefore have the potential to contribute to climate change. Increasing concern due to the presence of greenhouse gases, including high GWP refrigerants, in the atmosphere and their effect on global climate is leading to international policies aimed at phasing down the use of refrigerants with high global warming potentials. The HVAC&R industry is actively developing new environmentally friendly alternatives to replace the high GWP fluids currently in use. R-134a has been widely used in medium pressure refrigerant products, including medium and large capacity chillers, as the replacement for R-12. However, because of R-134a's high GWP(AR5) of 1300, the US EPA, through its Significant New Alternatives Program (SNAP) program, has placed a ban on the use of R-134a in chillers beginning in 2014. R-516A, also known as ARM-42, has been proposed as an alternative to R-134a. R-516A is an azeotropic blend of mostly R-1234yf (77.5%wt) with some R-134a (8.5%wt) and R- 152a (14%wt) that has thermodynamic characteristics very similar to R-134a. R-516A has a significantly lower GWP(AR5) of 130. However, it is mildly flammable, receiving an ASHRAE Standard 34 classification of A2L. Thermodynamic calculations predict that the capacity should be 1.7% lower and the efficiency should be 2.1% lower for R-516A compared to R-134a when operating at conditions typical of the AHRI Standard 550/590 rating point. This paper describes the thermodynamic characteristics of R-516A and reports the results of tests that were performed on a 105 RT (370 kW) air cooled screw chiller with R-134a and R-516A. Performance was measured over a range of ambient air temperatures from 65 degrees F to 125 degrees F (18 degrees C to 52 degrees C). At the AHRI Standard 550/590 rating conditions, measured capacity when running the unit with R-516A was about 2% lower and EER was reduced by 3.5% to 4.0% compared to R-134a. Given these results, R-516A can be considered a design compatible alternative to R-134a in water chiller products.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Chiller Performance Study with Refrigerant R290
    Fuadi, Zulfa
    Yatim, Ardiyansyah
    Rizky, Rachmah
    Aisyah, Nyayu
    Alhamid, Idrus
    Budihardjo, Budihardjo
    Putra, Nandy
    10TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2018): SMART CITY: ADVANCES IN THERMOFLUID TECHNOLOGY IN TROPICAL URBAN DEVELOPMENT, 2019, 2062
  • [32] Tactics to optimize the energy efficiency of a chiller system with multiple air-cooled chillers
    Chan, K
    Yu, FW
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1419 - 1424
  • [33] LOW GWP REFRIGERANT R454A FOR COMMERCIAL REFRIGERATION
    Flohr, Felix
    Arimoto, Hitomi
    Ohkubo, Shun
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 224 - 230
  • [34] Cycle analysis of air-cooled absorption chiller using a new working solution
    Yoon, JI
    Kwon, OK
    ENERGY, 1999, 24 (09) : 795 - 809
  • [35] Optimizing the pad thickness of evaporative air-cooled chiller for maximum energy saving
    Hao, Xiaoli
    Zhu, Cangzhou
    Lin, Yaolin
    Wang, Haiqiao
    Zhang, Guoqiang
    Chen, Youming
    ENERGY AND BUILDINGS, 2013, 61 : 146 - 152
  • [36] AERODYNAMIC PERFORMANCE OF AN AIR-COOLED RADIAL TURBINE - (COLD-AIR TESTING AND PERFORMANCE CALCULATION OF A RADIAL TURBINE WITH AIR-COOLED NOZZLES).
    Matsuo, Eito
    Kimura, Yoshito
    Tomioka, Makoto
    Nakazawa, Norio
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1987, 53 (485): : 149 - 156
  • [37] Wind effects on air-cooled condenser performance
    Borghei, Leila
    Khoshkhoo, Ramin Haghighi
    NEW ASPECTS OF FLUID MECHANICS, HEAT TRANSFER AND ENVIRONMENT, 2010, : 193 - +
  • [38] HIGH PERFORMANCE AIR-COOLED MODULE.
    Anon
    IBM technical disclosure bulletin, 1985, 28 (07): : 3058 - 3059
  • [39] EFFECT OF WIND ON AIR-COOLED CONDENSER PERFORMANCE
    Maulbetsch, John S.
    DiFilippo, Michael N.
    O'Hagan, Joseph
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 391 - +
  • [40] Enhance air-cooled heat exchanger performance
    Shastri, SS
    Karimi, IA
    Rangaiah, GP
    Yap, C
    HYDROCARBON PROCESSING, 2001, 80 (12): : 49 - +