Three-Phase Bone Scintigraphy in Chronic Epicondylitis

被引:4
|
作者
Pienimaki, Tuomo T. [1 ]
Takalo, Reijo J. [2 ]
Ahonen, Aapo K. [4 ]
Karppinen, Jaro I. [1 ,3 ]
机构
[1] Finnish Inst Occupat Hlth, FI-90220 Oulu, Finland
[2] Oulu Univ Hosp, Dept Radiol, Div Nucl Med, Oulu, Finland
[3] Oulu Univ Hosp, Dept Phys Med & Rehabil, Oulu, Finland
[4] Helsinki Univ Hosp, HUSLAB, Dept Clin Physiol & Nucl Med, Helsinki, Finland
来源
关键词
Bone and bones; Rehabilitation;
D O I
10.1016/j.apmr.2008.04.023
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the utility of 3-phase bone scintigraphy as a complementary diagnostic method in chronic epicondylitis. Design: A cross-sectional study. Setting: Hospital outpatient clinic admitting patients with musculoskeletal disorders. Participants: Patients (N=59; 68% women) with unilateral chronic epicondylitis. Interventions: Not applicable. Main Outcome Measures: Three-phase bone scintigraphy was performed after an intravenous injection of 550MBq (99m)technetium-labeled hydroxymethyline diphosphonate (Tc-99m-HDP) in the patients. Blood flow and blood pool phases were graded visually as normative or abnormal. In the bone metabolic phase, the scintigraphic radiograph images were evaluated using a transmission densitometer. The ratio between maximal bone uptake of Tc-99m-HDP in each epicondyle and the mean of that in the adjacent humerus was used as a bone uptake measure, which was compared with clinical data (pain questionnaire, pain drawing, cubital pain thresholds, muscle strength) and with work ability and lifestyle factors. Results: The bone uptake of Tc-99m-HDP of the affected epicondyle was 33% and 17% higher in men and women, respectively, compared with the corresponding healthy epicondyle (P <.001 and P=.007). High bone uptake of Tc-99m-HDP was associated with better work ability, grip strength, and muscle performance in both sexes but was not correlated with the pain measures. Blood flow phases had a positive correlation with the duration of symptoms and a negative correlation with the bone uptake of 99'Te-HDP, grip strength, and work ability. Conclusions: High bone uptake of Tc-99m-HDP among patients with chronic epicondylitis was associated with better muscle strength, work ability, and arm function. In chronic cases, a higher degree of bone uptake of Tc-99m-HDP may thus indicate a healing response in the bone tissue.
引用
收藏
页码:2180 / 2184
页数:5
相关论文
共 50 条
  • [41] Utility of three-phase bone scintigraphy in malignancy assessment in extraosseous lesions: Two different bone scan patterns
    Zaragoza-Ballester, P.
    Tabuenca, M. J.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2024, 43 (02): : 121 - 123
  • [42] Three-Phase Scintigraphy in Acute Lower Limb Ischemia
    Kudryashova, N.
    Sinyakova, O.
    Mikhailov, I.
    Migunova, E.
    Martirosyan, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S384 - S385
  • [43] Early detection of osteomyelitis in diabetic foot with ulcer using three-phase bone scintigraphy.
    Kumar, R.
    Kumar, K.
    Dhanwal, D.
    Gowda, N.
    Malhotra, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S32 - S32
  • [44] Value of pretherapeutic three-phase bone scintigraphy to predict the clinical outcome of patients receiving radiosynoviorthesis
    Kampen, WU
    Horn, M
    Brenner, W
    Zuhayra, M
    Henze, E
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 329P - 329P
  • [45] Three-phase bone scintigraphy has a low sensitivity for diagnosis of repetitive strain injury.
    Charron, M
    Di Lorenzo, C
    Kocoshis, S
    Villemagne, V
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 343P - 343P
  • [46] Three-Phase 99mTc-MDP Bone Scintigraphy and SPECT/CT in Pediatric Pseudodystrophy
    Usmani, Sharjeel
    Panchadar, Satish
    al Banna, Anwar
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (11) : 902 - 904
  • [47] A comparative study of 201Tl scintigraphy and three-phase bone scintigraphy following therapy in patients with bone and soft-tissue tumors
    Nishiyama, Y
    Yamamoto, Y
    Yokoe, K
    Kawaguchi, Y
    Toyama, Y
    Satoh, K
    Ohkawa, M
    ANNALS OF NUCLEAR MEDICINE, 2004, 18 (03) : 235 - 241
  • [48] A comparative study of 201Tl scintigraphy and three-phase bone scintigraphy in the following therapy in patients with bone and soft-tissue tumors.
    Yamamoto, Y
    Nishiyama, Y
    Kawaguchi, Y
    Satoh, K
    Ohkawa, M
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 132P - 132P
  • [49] Usefulness of asymmetry score on quantitative three-phase bone scintigraphy in the evaluation of complex regional pain syndrome
    Santhosh, Sampath
    Mittal, Bhagwant Rai
    Arun, Sasikumar
    Sood, Ashwani
    Bhattacharya, Anish
    Sharma, Aman
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2013, 28 (01): : 11 - 16
  • [50] Three-phase bone scintigraphy in humeral head fracture: Vascular supply and clinical decision making.
    Lupi, A
    Orsolon, P
    De Antoni, G
    Cerisara, D
    Nogarin, L
    Dri, AV
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1055 - 1055