Stability and safety of mini-screw implant anchorage in the oral orthodontics

被引:0
|
作者
Song, Lijuan [1 ,2 ]
Wu, Jun [1 ]
机构
[1] Nanchang Univ, Dept Orthodont, Affiliated Stomatol Hosp, Jiangxi Prov Key Lab Oral Biomed,Sch Stomatol, 49 Fuzhou Rd, Nanchang 330006, Jiangxi, Peoples R China
[2] Soochow Univ, Dept Orthodont, Stomatol Hosp, Suzhou Stomatol Hosp, Suzhou, Jiangsu, Peoples R China
关键词
Mini-screw implant anchorage; oral orthodontics; stability; safety; oral surgery department; MINISCREW IMPLANTS; BITE FORCE; EFFICIENCY;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To investigate the stability and safety of the mini-screw implant anchorage in oral orthodontics. Methods: In this study, we retrospectively reviewed the clinical data of 120 patients who received the oral orthodontics. Among all these patients, 63 patients who implemented the surgery of the mini-screw implant anchorage were enrolled into the experimental group, and 57 patients who received the enhanced headgear anchorage into the control group. We observed the efficacy of dental orthodontics, complete closure time of the extraction space, inclination angle of the upper central incisor, convexity of the upper central incisor, displacement of the molar, bite force, chewing efficiency and the incidence of adverse reactions. Results: For all patients, the orthodontic success rate in the experimental group was significantly higher than that in the control group (chi(2)=5.844, P=0.018); patients in the experimental group also suffered less due to the significantly shortened complete closure time of the extraction space in comparison with the control group (t=14.110, P < 0.001). Following treatment, the angle of inclination and the convexity of the upper central incisor in the experimental group were much larger than those in the control group (t=15.570 or 13.470, P < 0.001); but the recovery in the biting force and the chewing efficiency in the experimental group was superior to that in the control group (t=15.570, P < 0.001); while the incidence rate of the adverse reactions in the experimental group was significantly lower than that in the control group (chi(2)=8.952, P=0.005). Conclusion: In comparison with the traditional orthodontics, mini-screw implant anchorage can increase the success rate and efficacy of oral orthodontics, with shorter complete closing time of extraction space, lower incidence rate of the postoperative adverse reactions and promising stability and safety.
引用
收藏
页码:4028 / 4035
页数:8
相关论文
共 50 条
  • [31] Success Rates of Mini- and Microscrews as Skeletal Anchorage in Orthodontics
    Berens, A.
    Wiechmann, D.
    Rudiger, J.
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2005, 37 (04): : 283 - 287
  • [32] Mini-Implants in the Anchorage Armamentarium: New Paradigms in the Orthodontics
    Yamaguchi, Masaru
    Inami, Toshihiro
    Ito, Ko
    Kasai, Kazutaka
    Tanimoto, Yasuhiro
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2012, 2012
  • [33] Preliminary testing for reduction of insertion torque of orthodontic mini-screw implant using diamond-like carbon films
    Jongwannasiri, C.
    Charasseangpaisarn, T.
    Watanabe, S.
    SIAM PHYSICS CONGRESS 2019 (SPC2019): PHYSICS BEYOND DISRUPTION SOCIETY, 2019, 1380
  • [34] Volumetric Measurement of Root Resorption following Molar Mini-Screw Implant Intrusion Using Cone Beam Computed Tomography
    Li, Wen
    Chen, Fei
    Zhang, Feng
    Ding, Wanghui
    Ye, Qingsong
    Shi, Jiejun
    Fu, Baiping
    PLOS ONE, 2013, 8 (04):
  • [35] Influence of mini-screw diameter and loading conditions on static and dynamic assessments of bone-implant contact: An animal study
    Exposto, Cristina R.
    Oz, Ulas
    Westgate, Philip M.
    Huja, Sarandeep S.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 : 96 - 100
  • [36] Research on the micro-extrusion characteristic of mini-screw in the screw extruding spray head
    Bin Liu
    Yi Xie
    Mingxing Wu
    Polymer Bulletin, 2010, 64 : 727 - 738
  • [37] Implant anchorage: In vivo and in vitro analyses: Clusters for implant anchorage and safety
    Kistler, Manuel
    Schonhoff, Mareike
    Reulbach, Magnus
    Schleifenbaum, Stefan
    Hoelscher-Doht, Stefanie
    Hurschler, Christof
    Jahnke, Alexander
    ORTHOPADIE, 2024, 53 (07): : 519 - 526
  • [38] DORSAL PERCUTANEOUS CANNULATED MINI-SCREW FIXATION FOR FRACTURES OF THE HAMATE HOOK
    Scheufler, Oliver
    Radmer, Sebastian
    Andresen, Reimer
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2012, 17 (02): : 287 - 293
  • [39] Accuracy of mechanical torque-limiting gauges for mini-screw placement
    Schaetzle, Marc
    Golland, Dorota
    Roos, Malgorzata
    Stawarczyk, Bogna
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (08) : 781 - 788
  • [40] The effects of different antiseptic mouthwash on microbiota around orthodontic mini-screw
    Akbulut, Y.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (11) : 1507 - 1513