Multi-objective H-/H∞ fault detection observer design for Takagi-Sugeno fuzzy systems with unmeasurable premise variables: descriptor approach

被引:49
|
作者
Aouaouda, S. [1 ]
Chadli, M. [2 ]
Cocquempot, V. [3 ]
Khadir, M. Tarek [1 ]
机构
[1] Annaba Univ, Lab Gest Elect Document LabGED, Sidi Amar 23200, Annaba, Algeria
[2] Univ Picardie Jules Verne, MIS EA 4290, F-80039 Amiens, France
[3] Univ Lille 1, LAGIS UMR CNRS 8219, F-59655 Villeneuve Dascq, France
关键词
Takagi-Sugeno fuzzy models; descriptor approach; fault detection; disturbance; LMI; TOLERANT CONTROL; GENERATION;
D O I
10.1002/acs.2374
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper investigates the problem of robust fault detection observer design for nonlinear Takagi-Sugeno models with unmeasurable premise variables subject to sensor faults and unknown bounded disturbance. The main idea is to synthesize a robust fault detection observer by means of a mixed H-/H performance index. The considered observer is used to estimate jointly states and faults. Using the technique of descriptor system representation, we proposed a new less-conservative approach in term of a linear matrix inequality (LMI) by considering the sensor fault as an auxiliary state variable. A solution of the problem is obtained by using an iterative LMI procedure. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1031 / 1047
页数:17
相关论文
共 50 条
  • [21] Discrete-time Takagi-Sugeno singular systems with unmeasurable decision variables: state and fault fuzzy observer design
    Aitdaraou, Khaoula
    Essabre, Mohamed
    El Assoudi, Abdellatif
    El Yaagoubi, El Hassane
    ARCHIVES OF CONTROL SCIENCES, 2023, 33 (02) : 321 - 338
  • [22] Observer synthesis for a class of Takagi-Sugeno descriptor system with unmeasurable premise variable. Application to fault diagnosis
    Lopez-Estrada, F. R.
    Astorga-Zaragoza, C. M.
    Theilliol, D.
    Ponsart, J. C.
    Valencia-Palomo, G.
    Torres, L.
    INTERNATIONAL JOURNAL OF SYSTEMS SCIENCE, 2017, 48 (16) : 3419 - 3430
  • [23] Observer design for Takagi-Sugeno systems with unmeasurable premise variables using a non-quadratic Lyapunov function
    Hamdi, Wail
    Hammoudi, Mohamed Yacine
    Hamiane, Madina
    ISA TRANSACTIONS, 2024, 154 : 476 - 487
  • [24] SYNTHESIS OF FRACTIONAL ORDER FUZZY OBSERVER FOR A FRACTIONAL ORDER TAKAGI-SUGENO MODEL WITH UNMEASURABLE PREMISE VARIABLES
    Djeddi, Abdel Ghani
    Amieur, Toufik
    Hannahi, Fareh
    Metatla, Samir
    Aouiche, Abdelaziz
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2024, 69 (01): : 45 - 50
  • [25] Robust Zonotopic Observer Design: Avoiding Unmeasured Premise Variables for Takagi-Sugeno Fuzzy Systems
    Pourasghar, Masoud
    Nguyen, Anh-Tu
    Guerra, Thierry-Marie
    IFAC PAPERSONLINE, 2021, 54 (04): : 68 - 73
  • [26] H-/H∞ fault detection filter design for discrete-time Takagi-Sugeno fuzzy system
    Chadli, Mohammed
    Abdo, Ali
    Ding, Steven X.
    AUTOMATICA, 2013, 49 (07) : 1996 - 2005
  • [27] Design of robust fault detection observer for Takagi-Sugeno models using the descriptor approach
    Maha Bouattour
    Mohammed Chadli
    Mohamed Chaabane
    Ahmed El Hajjaji
    International Journal of Control, Automation and Systems, 2011, 9 : 973 - 979
  • [28] Design of Robust Fault Detection Observer for Takagi-Sugeno Models Using the Descriptor Approach
    Bouattour, Maha
    Chadli, Mohammed
    Chaabane, Mohamed
    El Hajjaji, Ahmed
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2011, 9 (05) : 973 - 979
  • [29] Simplified LMI Conditions for Takagi-Sugeno Fuzzy Observer Design with Unmeasured Premise Variables
    Dong, Bao-Trung
    Nguyen, Thi-Van-Anh
    INTERNATIONAL JOURNAL OF FUZZY SYSTEMS, 2024, : 762 - 773
  • [30] Finite-Frequency H-/H∞ Memory Fault Detection Filtering Design for Uncertain Takagi-Sugeno Fuzzy Affine Systems
    Zhao, Rong
    Liu, Lu
    Feng, Gang
    IEEE TRANSACTIONS ON FUZZY SYSTEMS, 2022, 30 (07) : 2595 - 2609