Sensitivity of subject-specific models to errors in musculo-skeletal geometry

被引:50
|
作者
Carbone, V. [1 ]
van der Krogt, M. M. [1 ,2 ]
Koopman, H. F. J. M. [1 ]
Verdonschot, N. [1 ,3 ]
机构
[1] Univ Twente, Lab Biomech Engn, NL-7500 AE Enschede, Netherlands
[2] Vrije Univ Amsterdam, Dept Rehabil Med, Res Inst MOVE, Med Ctr, Amsterdam, Netherlands
[3] Radboud Univ Nijmegen, Orthopaed Res Lab, Med Ctr, NL-6525 ED Nijmegen, Netherlands
关键词
Subject-specific modeling; Sensitivity analysis; Musculo-skeletal geometry; Muscle-tendon attachment points; Muscle-tendon via points; LOWER-EXTREMITY; ANGLE RELATIONSHIP; MUSCLE MODEL; JOINT; HIP; PARAMETERS; TENDON; ANKLE; KNEE; REPLACEMENT;
D O I
10.1016/j.jbiomech.2012.06.026
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Subject-specific musculo-skeletal models of the lower extremity are an important tool for investigating various biomechanical problems, for instance the results of surgery such as joint replacements and tendon transfers. The aim of this study was to assess the potential effects of errors in musculo-skeletal geometry on subject-specific model results. We performed an extensive sensitivity analysis to quantify the effect of the perturbation of origin, insertion and via points of each of the 56 musculo-tendon parts contained in the model. We used two metrics, namely a Local Sensitivity Index (LSI) and an Overall Sensitivity Index (051), to distinguish the effect of the perturbation on the predicted force produced by only the perturbed musculo-tendon parts and by all the remaining musculo-tendon parts, respectively, during a simulated gait cycle. Results indicated that, for each musculo-tendon part, only two points show a significant sensitivity: its origin, or pseudo-origin, point and its insertion, or pseudo-insertion, point. The most sensitive points belong to those musculo-tendon parts that act as prime movers in the walking movement (insertion point of the Achilles Tendon: LSI = 15.56%, OSI = 7.17%; origin points of the Rectus Femoris: LSI = 13.89%, OSI = 2.44%) and as hip stabilizers (insertion points of the Gluteus Medius Anterior: LSI = 17.92%, OSI = 2.79%; insertion point of the Gluteus Minimus: LSI = 21.71%, OSI = 2.41%). The proposed priority list provides quantitative information to improve the predictive accuracy of subject-specific musculo-skeletal models. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2476 / 2480
页数:5
相关论文
共 50 条
  • [31] Protocol for constructing subject-specific biomechanical models of knee joint
    Yang, N. H.
    Canavan, P. K.
    Nayeb-Hashemi, H.
    Najafi, B.
    Vaziri, A.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (05) : 589 - 603
  • [32] Subject-Specific Geometry of FE Lumbar Spine Models for the Replication of Fracture Locations Using Dynamic Drop Tests
    Rieger, Laura K.
    Shah, Alok
    Schick, Sylvia
    Draper, Dustin B.
    Cutlan, Rachel
    Peldschus, Steffen
    Stemper, Brian D.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (4) : 816 - 831
  • [33] Sensitivity of a subject-specific musculoskeletal model to the uncertainties on the joint axes location
    Martelli, Saulo
    Valente, Giordano
    Viceconti, Marco
    Taddei, Fulvia
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (14) : 1555 - 1563
  • [34] Subject-specific functional localizers increase sensitivity and functional resolution of multi-subject analyses
    Nieto-Castanon, Alfonso
    Fedorenko, Evelina
    [J]. NEUROIMAGE, 2012, 63 (03) : 1646 - 1669
  • [35] A NURBS-based technique for subject-specific construction of knee bone geometry
    Au, Anthony G.
    Palathinkal, Darren
    Liggins, Adrian B.
    Raso, V. James
    Carey, Jason
    Lambert, Robert G.
    Amirfazli, A.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2008, 92 (01) : 20 - 34
  • [36] Representation of bone heterogeneity in subject-specific finite element models for knee
    Au, Anthony G.
    Liggins, Adrian B.
    Raso, V. James
    Carey, Jason
    Amirfazli, A.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2010, 99 (02) : 154 - 171
  • [37] Deep transfer learning compared to subject-specific models for sEMG decoders
    Lehmler, Stephan Johann
    Saif-ur-Rehman, Muhammad
    Tobias, Glasmachers
    Iossifidis, Ioannis
    [J]. JOURNAL OF NEURAL ENGINEERING, 2022, 19 (05)
  • [38] Image driven subject-specific finite element models of spinal biomechanics
    Zanjani-Pour, Sahand
    Winlove, C. Peter
    Smith, Christopher W.
    Meakin, Judith R.
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (06) : 919 - 925
  • [39] Validation of subject-specific cardiovascular system models from porcine measurements
    Revie, James A.
    Stevenson, David J.
    Chase, J. Geoffrey
    Hann, Christopher E.
    Lambermont, Bernard C.
    Ghuysen, Alexandre
    Kolh, Philippe
    Shaw, Geoffrey M.
    Heldmann, Stefan
    Desaive, Thomas
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2013, 109 (02) : 197 - 210
  • [40] Validation and evaluation of subject-specific finite element models of the pediatric knee
    Ayda Karimi Dastgerdi
    Amir Esrafilian
    Christopher P. Carty
    Azadeh Nasseri
    Alireza Yahyaiee Bavil
    Martina Barzan
    Rami K. Korhonen
    Ivan Astori
    Wayne Hall
    David John Saxby
    [J]. Scientific Reports, 13