Prospective evaluation of aerosol delivery by a powered nasal nebulizer in the cadaver model

被引:23
|
作者
Manes, R. Peter [2 ]
Tong, Liyue [3 ]
Batra, Pete S. [1 ]
机构
[1] Univ Texas SW Med Ctr Dallas, Dept Otolaryngol Head & Neck Surg, Comprehens Skull Base Program, Dallas, TX 75390 USA
[2] Yale Univ, Sch Med, Sect Otolaryngol, New Haven, CT USA
[3] Univ Texas SW Med Ctr Dallas, Dept Clin Sci, Dallas, TX 75390 USA
关键词
chronic sinusitis; drug delivery; nebulizer; sinus surgery; topical therapy; CHRONIC RHINOSINUSITIS; CONTROLLED-TRIAL; SINUS SURGERY; IRRIGATION; THERAPY;
D O I
10.1002/alr.20057
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Background: The objective of this study was to compare the distribution of aerosol delivered via a powered nasal nebulizer device in 5 fresh frozen-cadaver heads (10 total sides). Methods: Nasoneb (R) (Medinvent, St. Paul, MN) was used to deliver a total volume of 10 mL (9 mL saline and 1 mL of 10% fluorescein). Aerosol distribution was assessed in 3 trials: (1) unoperated nose; (2) post-functional endoscopic sinus surgery (FESS); and (3) post-FESS with endoscopic modified Lothrop procedure (EML). Two independent observers rated the distribution of the fluorescein-dyed saline in the anterior nasal cavity (ANC), olfactory cleft (OC), middle meatus (MM), sphenoethmoid recess (SER), nasopharynx (NP), along with maxillary sinus (MS), ethmoid cavity (EC), sphenoid sinus (SS), frontal sinus (FS), and frontal neo-ostium (F-NEO) in the operated specimens. Results: The nebulizer consistently delivered aerosolized saline to the ANC, MM/EC, and SER/SS across the 3 trials. A statistically significant increase in delivery was noted to the MM (p = 0.044) post-FESS. In addition, a statistically significant increase in delivery to the F-NEO was noted post-FESS with EML (p = 0.001). Multiplicity adjustment done for the FESS group showed statistically superior delivery to the EC vs OC (p = 0.031) and FS (p = 0.02) and to the SS vs FS (p = 0.031). Multiplicity adjustment after FESS with EML improved delivery to the FS, resulting in no statistical difference in aerosol delivery between F-NEO and EC or SS. Conclusion: The nebulizer consistently delivered aerosolized saline to multiple nasal subsites, with improvement in delivery seen to the middle meatal region after FESS and F-NEO after FESS with EML. This may have important implications for the delivery of topical medications to the paranasal sinuses in the postoperative setting. (C) 2011 ARS-AAOA, LLC.
引用
收藏
页码:366 / 371
页数:6
相关论文
共 50 条
  • [21] Suitability of caspofungin for aerosol delivery - Physicochemical profiling and nebulizer choice
    Wong-Beringer, A
    Lambros, MP
    Beringer, PM
    Johnson, DL
    CHEST, 2005, 128 (05) : 3711 - 3716
  • [22] AEROSOL BRONCHODILATOR DELIVERY DURING MECHANICAL VENTILATION - NEBULIZER OR INHALER
    HESS, D
    CHEST, 1991, 100 (04) : 1103 - 1104
  • [23] AEROSOL DEPOSITION IN MECHANICALLY VENTILATED PATIENTS - OPTIMIZING NEBULIZER DELIVERY
    ORIORDAN, TG
    PALMER, LB
    SMALDONE, GC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 149 (01) : 214 - 219
  • [24] AEROSOL DEPOSITION IN MECHANICALLY VENTILATED PATIENTS - OPTIMIZING NEBULIZER DELIVERY
    ORIORDAN, TG
    PALMER, L
    SMALDONE, GC
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A895 - A895
  • [25] DELIVERY AND RETENTION OF AN INSULIN AEROSOL PRODUCED BY A NEW JET NEBULIZER
    JENDLE, J
    KARLBERG, BE
    PERSLIDEN, J
    FRANZEN, L
    ARBORELIUS, M
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1995, 8 (03): : 243 - 254
  • [26] Irrigation penetration of nasal delivery systems: A cadaver study
    Abadie, Wesley M.
    McMains, Kevin C.
    Weitzel, Erik Kent
    INTERNATIONAL FORUM OF ALLERGY & RHINOLOGY, 2011, 1 (01) : 46 - 49
  • [27] IN VITRO COMPARISON OF BREATH SYNCHRONIZED AND CONTINUOUS AEROSOL VIA VIBRATING MESH NEBULIZER WITH DIFFERENT POSITION AND FLOWS IN ADULT TRANS-NASAL AEROSOL DELIVERY
    Li, Jie
    Wu, Wei
    Fink, James B.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2019, 32 (03) : A20 - A20
  • [28] Comparison of nasal deposition and clearance of aerosol generated by a nebulizer and an aqueous spray pump
    Suman, JD
    Laube, BL
    Dalby, R
    PHARMACEUTICAL RESEARCH, 1999, 16 (10) : 1648 - 1652
  • [29] Comparison of Nasal Deposition and Clearance of Aerosol Generated by a Nebulizer and an Aqueous Spray Pump
    Julie D. Suman
    Beth L. Laube
    Richard Dalby
    Pharmaceutical Research, 1999, 16 : 1648 - 1652
  • [30] Fabrication and Characterization of Medical Mesh-Nebulizer for Aerosol Drug Delivery
    Choi, Kyong-Hoon
    Moon, Sang-Hyub
    Park, Su-Kang
    Cho, Guangsup
    Nam, Ki Chang
    Park, Bong Joo
    APPLIED SCIENCES-BASEL, 2018, 8 (04):