Visualization and quantification of flow and velocity fields in intracranial arteriovenous malformations using phase-contrast MR angiography

被引:10
|
作者
Grinstead, JW
Sinha, S
Tateshima, S
Nien, YL
Vinuela, F
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Siemens Med Solut, Los Angeles, CA 90095 USA
[3] Atsugi City Hosp, Dept Neurosurg, Atsugi, Kanagawa 2430004, Japan
[4] Keio Univ, Sch Engn, Dept Syst Design Engn, Kohoku Ku, Yokohama 2288522, Japan
关键词
angiography; cine MRI; congenital malformations; hemodynamics; neuroimaging;
D O I
10.2214/AJR.04.1375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study was to describe postprocessing tools for MR phase-contrast flow quantification images and apply those tools to cerebral arteriovenous malformations (AVMs) to visualize blood flow dynamics noninvasively. CONCLUSION. Inflow and outflow zones were clearly depicted at different regions in the AVM. The processed images showed flow patterns including vortical flow and variations in velocity over the cardiac cycle. Particle tracking gave an impression of the overall flow state and of the venous drainage system in particular.
引用
收藏
页码:553 / 555
页数:3
相关论文
共 50 条
  • [31] ACCURACY OF MR PHASE-CONTRAST VELOCITY-MEASUREMENTS FOR UNSTEADY-FLOW
    FRAYNE, R
    STEINMAN, DA
    ETHIER, CR
    RUTT, BK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04): : 428 - 431
  • [32] Optimized visualization of vessels in contrast enhanced intracranial MR angiography
    Parker, DL
    Goodrich, KC
    Alexander, AL
    Buswell, HR
    Blatter, DD
    Tsuruda, JS
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) : 873 - 882
  • [33] In vivo Velocity and Flow Errors Quantification by Phase-Contrast Magnetic Resonance Imaging
    Garcia, J.
    Kadem, L.
    Larose, E.
    Pibarot, P.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1377 - +
  • [34] Quantification of hepatic blood flow using a high-resolution phase-contrast MR imaging sequence
    Knight-Greenfield, Ashley
    Dyvorne, Hadrien
    Besa, Cecilia
    Cooper, Nancy
    Schiano, Thomas D.
    Taouli, Bachir
    HEPATOLOGY, 2013, 58 : 961A - 961A
  • [35] Measuring blood flow by nontriggered 2D phase-contrast MR angiography
    Bakker, CJG
    Hartkamp, MJ
    Mali, WPTM
    MAGNETIC RESONANCE IMAGING, 1996, 14 (06) : 609 - 614
  • [36] Cerebral arteriovenous malformations (AVMs): Assessment of vascular characteristics and clinical steel phenomenon by cine phase-contrast MR flow-measurements
    Essig, M
    Debus, J
    Schoenberg, SO
    Bock, M
    Scorzin, J
    Van Kaick, G
    RADIOLOGY, 2000, 217 : 386 - 386
  • [37] Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI
    Petersson, Sven
    Dyverfeldt, Petter
    Sigfridsson, Andreas
    Lantz, Jonas
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1249 - 1255
  • [38] Quantification of flow through intracranial arteriovenous malformations using Angiographic Parametric Imaging (API)
    Williams, Kyle A.
    Bhurwani, Mohammed Mahdi Shiraz
    Snyder, Kenneth, V
    Levy, Elad, I
    Davies, Jason M.
    Siddiqui, Adnan H.
    Ionita, Ciprian N.
    MEDICAL IMAGING 2020: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11317
  • [39] A PITFALL IN DETECTION OF INTRACRANIAL UNRUPTURED ANEURYSMS ON 3-DIMENSIONAL PHASE-CONTRAST MR-ANGIOGRAPHY
    ARAKI, Y
    KOHMURA, E
    TSUKAGUCHI, I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1618 - 1623
  • [40] FLOW-VELOCITY CHANGE OF THE CORTICAL VEIN DURING FUNCTIONAL BRAIN ACTIVATION MEASURED WITH PHASE-CONTRAST MR-ANGIOGRAPHY
    NAKAJIMA, K
    NARUSE, S
    FURUYA, S
    YAMADA, K
    MORISHITA, H
    KIZU, O
    RADIOLOGY, 1995, 197 : 167 - 167