Improving the time-resolution and signal-to-noise ratio of ultrasonic NDE signals

被引:96
|
作者
Honarvar, F
Sheikhzadeh, H
Moles, M
Sinclair, AN
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Toronto, ON M5S 3G8, Canada
[2] KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran
[3] Amir Kabir Univ, Dept Elect Engn, Tehran, Iran
[4] RD Tech, Mississauga, ON L4W 3N8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ultrasonic testing; signal processing; Wiener filtering; autoregressive spectral extrapolation;
D O I
10.1016/j.ultras.2003.09.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasonic testing signals are sometimes hard to interpret because of low signal-to-noise ratio (SNR) or overlapping echoes. The combination of Wiener filtering and autoregressive spectral extrapolation has proven to be capable of improving the SNR and time resolution. However, these signal processing techniques are not sufficiently robust to be used in industrial non-destructive testing applications. This is mostly due to arbitrary manner of selection of the signal processing parameters associated with these techniques. In this paper, a new approach, which eliminates the need for arbitrary assignment of some of the parameters is described. This new approach is more robust and suitable for practical applications, and is demonstrated by considering both simulated and experimental signals. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:755 / 763
页数:9
相关论文