Bilateral Comparison of 1 V and 10 V Standards between the NIS (Egypt) and the BIPM, August to September 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)

被引:0
|
作者
Solve, S. [1 ]
Chayramy, R. [1 ]
Stock, M. [1 ]
Mageed, Hala M. Abdel [2 ]
Aladdin, Omar M. [2 ]
Raouf, M. Helmy A. [2 ]
机构
[1] Bur Int Poids & Mesures, Sevres, France
[2] Natl Inst Stand, MA El Sadat Tersa, Giza 11221, Egypt
关键词
DC voltage - Josephson voltage standards - Key comparison - Main texts - Reference standard - Standard uncertainty - Travelling standard - Voltage reference - Voltage standard;
D O I
10.1088/0026-1394/52/1A/01011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1 V and 10 V voltage reference standards of the BIPM and the National Institute for Standards (NIS), Giza, Egypt, was carried out from August to September 2014. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_B (ZB) and BIPM_C (ZC), were transported as hand luggage on board an airplane to NIS and back to BIPM. At NIS, the reference standard for DC voltage is a Josephson Voltage Standard. The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard. At the BIPM, the travelling standards were calibrated, before and after the measurements at NIS, with the Josephson Voltage Standard. Results of all measurements were corrected for the dependence of the output voltages of the Zener standards on internal temperature and ambient atmospheric pressure. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by NIS, at the level of 1.018 V and 10 V, at NIS, U-NIS, and those assigned by the BIPM, at the BIPM, U-BIPM, at the reference date of the 7 September 2014. U-NIS - U-BIPM = 0.09 mu V; u(c) = 0.08 mu V, at 1 V U-NIS - U-BIPM = 0.22 mu V; u(c) = 0.14 mu V, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at NIS, based on KJ-90, and the uncertainty related to the comparison. This is a satisfactory result. The comparison result shows that the voltage standards maintained by NIS and the BIPM were equivalent, within their stated standard uncertainties, on the mean date of the comparison.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Bilateral comparison of 1 V and 10 V standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Simionescu, M.
    CÎrneanu, L.
    [J]. Metrologia, 2014, 51 (1A)
  • [2] Bilateral Comparison of 1 V and 10 V Standards between the INM (Romania) and the BIPM, August to October 2013 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Simionescu, M.
    Cirneanu, L.
    [J]. METROLOGIA, 2014, 51
  • [3] Bilateral comparison of 1 V and 10 V standards between the DMDM (Serbia) and the BIPM, January to March 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Pantelic-Babic, J.
    Sofranac, Z.
    Zivkovic, V.
    [J]. METROLOGIA, 2015, 52
  • [4] Bilateral Comparison of 1 V and 10 V Standards between the NIMT (Thailand) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Pimsut, S.
    [J]. METROLOGIA, 2015, 52
  • [5] Bilateral Comparison of 1 V and 10 V Standards between the SMD (Belgium) and the BIPM October to December 2014 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Vlad, D.
    [J]. METROLOGIA, 2015, 52
  • [6] Bilateral Comparison of 1.018 V and 10 V Standards between the INTI (Argentina) and the BIPM, August to October 2009 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Tonina, A.
    Iuzzolino, R.
    Bierzychudek, M.
    Real, M.
    Solve, S.
    Chayramy, R.
    Stock, M.
    [J]. METROLOGIA, 2010, 47
  • [7] Bilateral comparison of 1.018 V and 10 V standards between the KRISS (Republic of Korea) and the BIPM, February 2008 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Stock, M.
    Kim, K-T
    Song, W.
    Kim, M-S
    Chong, Y.
    [J]. METROLOGIA, 2008, 45
  • [8] Bilateral Comparison of 1.018 V and 10 V Standards between the KEBS (Kenya) and the BIPM January to March 2018 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Aguko, Gibson O.
    Stock, M.
    [J]. METROLOGIA, 2018, 55
  • [9] Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, Stephane
    Chayramy, Regis
    Stock, Michael
    Zouaoui, Jihène
    [J]. Metrologia, 2023, 60 (1 A)
  • [10] Bilateral Comparison of 1.018 V and 10 V Standards between the NMISA (South Africa) and the BIPM April to June 2017 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
    Solve, S.
    Chayramy, R.
    Matlejoane, A. M.
    Magagula, L.
    Stock, M.
    [J]. METROLOGIA, 2018, 55