Development and validation of a chemometric method for direct determination of hydrochlorothiazide in pharmaceutical samples by diffuse reflectance near infrared spectroscopy

被引:54
|
作者
Ferreira, Marcus H. [1 ,2 ]
Braga, Jez W. B. [3 ,5 ]
Sena, Marcelo M. [1 ,4 ,5 ]
机构
[1] Univ Estadual Goias, UnUCET, BR-75001970 Anapolis, Go, Brazil
[2] IQUEGO, Ind Quim Estado Goias SA, BR-74450010 Goiania, Go, Brazil
[3] Univ Brasilia, Inst Quim, BR-70904970 Brasilia, DF, Brazil
[4] Univ Fed Minas Gerais, ICEx, Dept Quim, BR-31270901 Belo Horizonte, MG, Brazil
[5] Inst Nacl Ciencia & Tecnol Bioanalit, BR-13083970 Campinas, SP, Brazil
关键词
Multivariate calibration; Analytical validation; Net analyte signal; NIR; Quality control; Active pharmaceutical ingredient; MULTIVARIATE CALIBRATION MODEL; FIGURES; MERIT; QUANTIFICATION; ELECTRODE; TABLETS; SENSOR;
D O I
10.1016/j.microc.2012.03.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work developed and validated a new multivariate diffuse reflectance near infrared method for direct determination of hydrochlorothiazide in powder pharmaceutical samples. The best partial least squares (PIS) model was obtained in the spectral region from 1640 to 1780 nm, with mean centered data preprocessed by first derivative and Savitzky-Golay smoothing followed by vector normalization. This model was built with 4 latent variables and provided a root mean square error of prediction of 1.7%. The method was validated according to the appropriate regulations in the range from 21.25 to 29.00 mg of hydrochlorothiazide per 150 mg of powder (average mass tablet), by the estimate of figures of merit, such as accuracy, precision, linearity, analytical sensitivity, capability of detection, bias and residual prediction deviation (RPD). The concept of net analyte signal (NAS) was used to estimate some figures of merit and to plot a pseudo-univariate calibration curve. The results for determinations in powdered manufactured tablets were in agreement with those of the official high performance liquid chromatographic method (HPLC). Finally, the method was extrapolated for determinations in intact tablets, providing prediction errors smaller than +/-9%. The developed method presented the advantage of being about fifteen times faster than the reference HPLC method. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 50 条
  • [21] Determination of furosemide in pharmaceutical formulations by diffuse reflectance spectroscopy
    Gotardo, MA
    Gigante, AC
    Pezza, L
    Pezza, HR
    [J]. TALANTA, 2004, 64 (02) : 361 - 365
  • [22] Nondestructive direct determination of heroin in seized illicit street drugs by diffuse reflectance near-infrared spectroscopy
    Moros, Javier
    Galipienso, Nieves
    Vilches, Rocio
    Garrigues, Salvador
    de la Guardia, Miguel
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (19) : 7257 - 7265
  • [23] Rapid and nondestructive analysis of pharmaceutical products using near-infrared diffuse reflectance spectroscopy
    Li, Pao
    Du, Guorong
    Cai, Wensheng
    Shao, Xueguang
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 288 - 294
  • [24] NEAR-INFRARED DIFFUSE REFLECTANCE SPECTROSCOPY OF COAL
    FYSH, SA
    SWINKELS, DAJ
    FREDERICKS, PM
    [J]. APPLIED SPECTROSCOPY, 1985, 39 (02) : 354 - 357
  • [25] Determination of protein in ground wheat samples by mid-infrared diffuse reflectance spectroscopy
    Reeves, JB
    DelWiche, SR
    [J]. APPLIED SPECTROSCOPY, 1997, 51 (08) : 1200 - 1204
  • [26] Direct and rapid determination of sulphate in environmental samples with diffuse reflectance Fourier transform infrared spectroscopy using KBr substrate
    Verma, Santosh Kumar
    Deb, Manas Kanti
    [J]. TALANTA, 2007, 71 (04) : 1546 - 1552
  • [27] DETERMINATION OF ASCORBIC-ACID IN PHARMACEUTICAL PREPARATIONS BY NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    DELAPEZUELA, C
    [J]. TALANTA, 1993, 40 (11) : 1671 - 1676
  • [28] Determination of the Coptis extract alkaloids using near-infrared diffuse reflectance spectroscopy
    Qu, HB
    Liu, Q
    Cheng, YY
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (04) : 477 - 480
  • [29] DETERMINATION OF SODIUM-CHLORIDE IN MEAT BY NEAR-INFRARED DIFFUSE REFLECTANCE SPECTROSCOPY
    BEGLEY, TH
    LANZA, E
    NORRIS, KH
    HRUSCHKA, WR
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1984, 32 (05) : 984 - 987
  • [30] Determination of bilirubin using near infrared diffuse reflectance spectroscopy with selective concentration on β-cyclodextrin
    Wang, Cuicui
    Cai, Wensheng
    Shao, Xueguang
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2016, 24 (04) : 345 - 352