Numerical Study of Particle-Fluid Flow Under AC Electrokinetics in Electrode-Multilayered Microfluidic Device

被引:15
|
作者
Sato, Norikazu [1 ]
Yao, Jiafeng [2 ]
Sugawara, Michiko [3 ]
Takei, Masahiro [3 ]
机构
[1] JFE Technores Corp, Sensing & Proc Solut Div, Tokyo, Japan
[2] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Jiangsu, Peoples R China
[3] Chiba Univ, Dept Mech Engn, Chiba, Japan
基金
中国国家自然科学基金; 日本学术振兴会;
关键词
Cell manipulation; AC electrokinetics; 3D simulation; electrothermal; thermal buoyancy; dielectrophoresis; SEPARATION; FIELDS; MOTION; DIELECTROPHORESIS; MICROELECTRODES; MEDIA; CELLS;
D O I
10.1109/TBME.2018.2849004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A particle-fluid flow under alternating current (ac) electrokinetics was numerically simulated to investigate the three-dimensional (3-D) particle motion in a complex electric field of a high conductivity medium generated by an electrode-multilayered microfluidic device. The simulation model coupling thermal-fluid-electrical and dispersed particle problems incorporates three ac electrokinetics (ACEK) phenomena, namely, the ac electrothermal effect (ACET), thermal buoyancy (TB), and dielectrophoresis (DEP). The electrode-multilayered microfluidic device was fabricated with 40 electrodes exposed at the flow channel sidewalls in five cross sections. The governing equations of the simulation model are solved by the Eulerian-Lagrangian method with finite volume discretization. Fluid flow simulations in three cases with or without consideration of ACET and TB are performed to clarify the contributions of these phenomena. The fluid flow is found to be composed of short-range vortices due to ACET and long-range circulation due to TB based on the features of the electrode-multilayered microfluidic device. The 3-D particle trajectory influenced by the fluid flow is compared with four values of the real part of the Clausius-Mossotti (CM) factor to evaluate the DEP phenomenon. The simulation model is validated by experiments using a cell suspension. The pattern of cell trajectories in the upper part of the flow channel measured by particle tracking velocimetry agrees with the simulated pattern. By comparison of the simulation and experiment, it is found that the cells moving straight away from the electrode on the focal plane are decelerated within the region of 60 mu m from the electrode by positive-DEP with Re[K(omega)] = 0.08-0.11. Furthermore, the 3-D DEP-effective region and the ACET and TB dominant regions for the cells are predicted by evaluating the particle-fluid relative velocity due to DEP force with Re[K(omega)] = 0.10. Consequently, the flow mechanism and dominant region of each ACEK phenomenon in the device are clarified from the 3-D simulation validated by the experiments.
引用
收藏
页码:453 / 463
页数:11
相关论文
共 50 条
  • [21] The study of particle-fluid flow in narrow, curved slots to enhance comprehension of particle transport mechanisms in complex fractures
    Qu, Hai
    Hu, Yushuang
    Liu, Ying
    Wang, Rui
    Tang, Shimao
    Xue, Ling
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2021, 92
  • [22] A numerical study on particle behaviors of fluid flow in pulverizer
    Yun, Tae-Jong
    Oh, Won-Bin
    Lee, Bo-Ram
    Liang, Zong-Liang
    Park, Min-Ho
    Kim, Ill-Soo
    MATERIALS TODAY-PROCEEDINGS, 2020, 22 : 1939 - 1948
  • [23] Non-uniform pumping flow model for the couple stress particle-fluid under magnetic effects
    Bhatti, M. M.
    Zeeshan, A.
    Asif, M. Aleem
    Ellahi, R.
    Sait, Sadiq M.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2022, 209 (08) : 1058 - 1069
  • [24] MICROPOLAR FLUID MODEL DESCRIPTION FOR DILUTE PARTICLE-FLUID SYSTEM: A CASE STUDY OF LID-DRIVEN CAVITY FLOW
    Wang, Lian
    Zhang, Yongchao
    Chu, Xihua
    Sun, Hongguang
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2024, 56 (10): : 2827 - 2837
  • [25] Numerical and experimental study of the fluid flow through a medical device
    Nicolas, M.
    Palero, V. R.
    Pena, E.
    Arroyo, M. P.
    Martinez, M. A.
    Malive, M.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2015, 61 : 170 - 178
  • [26] Study of variable magnetic field and endoscope on peristaltic blood flow of particle-fluid suspension through an annulus
    Bhatti M.M.
    Zeeshan A.
    Biomedical Engineering Letters, 2016, 6 (4) : 242 - 249
  • [27] Numerical and Experimental Investigation of AC Electrothermal Flow Pumping in Microfluidic Devices: Influence of Electrode Pair Count on Velocity
    Moradi, Reza
    Ramiar, Abas
    Ghasemi, Amirhosein
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 382
  • [28] Numerical Investigation of Microfluidic flow under AC applied electric field : Enhanced of binding reaction for a biosensor
    Selmi, Marwa
    Echouchene, F.
    Belmabrouk, H.
    2014 5TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2014,
  • [29] Numerical study of flow state for a magnetic fluid heat transport device
    Yamaguchi, H
    Kobori, I
    Kobayashi, N
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 201 : 260 - 263
  • [30] Numerical study of heat transfer and Hall current impact on peristaltic propulsion of particle-fluid suspension with compliant wall properties
    Bhatti, M. M.
    Ellahi, Rahmat
    Zeeshan, A.
    Marin, M.
    Ijaz, N.
    MODERN PHYSICS LETTERS B, 2019, 33 (35):