Immediate Weight Bearing of Comminuted Supracondylar Femur Fractures Using Locked Plate Fixation

被引:21
|
作者
Granata, Jaymes D. [1 ]
Litsky, Alan S. [1 ]
Lustenberger, David P. [1 ]
Probe, Robert A. [2 ]
Ellis, Thomas J. [1 ]
机构
[1] Ohio State Univ, Dept Orthopaed, Columbus, OH 43205 USA
[2] Scott & White Mem Hosp & Clin, Temple, TX 76508 USA
关键词
DISTAL FEMORAL FRACTURES; BLADE PLATE; LOCKING; STABILIZATION; CONSTRUCT; FORCES; SHAFT; LISS; NAIL;
D O I
10.3928/01477447-20120725-21
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, some studies have recommended earlier weight bearing. The purpose of the current study was to determine the biomechanical feasibility of an immediate weight-bearing rehabilitation protocol to encourage healing of distal femur fractures treated with lateral locked plate fixation. Sixteen fresh-frozen cadaveric femora were used for this study. A 2.5-cm supracondylar gap osteotomy was made. Ten-hole, 4.5-mm distal femur locking plates were used with a standardized screw configuration that maximized the working length. The specimens were placed in a servohydraulic testing machine and axially loaded (unidirectional) at 1 Hz for up to 200,000 cycles. Failure was defined as 1 cm of deformation of the construct. The staircase method was used to determine the fatigue limit of the construct. The fatigue limit was calculated to be 1329 +/- 106 N. No specimen failed through the non-locking diaphyseal screws. Plastic deformation, when present, occurred at the metaphyseal flare of the plate. The fatigue limit of the locked plate constructs equaled 1.9 times body weight for an average 70-kg patient over a simulated 10-week postoperative course. Given that distal femoral loads during gait have been estimated to be more than 2 times body weight, the data from this study do not support immediate full weight bearing.
引用
收藏
页码:E1210 / E1213
页数:4
相关论文
共 50 条
  • [31] METHOD OF INTERNAL-FIXATION OF SUPRACONDYLAR FRACTURES OF THE FEMUR
    BAIJAL, E
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1979, 11 (02): : 115 - 122
  • [32] RESULTS OF RIGID FIXATION IN 54 SUPRACONDYLAR FRACTURES OF THE FEMUR
    DELLATORRE, P
    AGLIETTI, P
    ALTISSIMI, M
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1980, 97 (03) : 177 - 183
  • [33] Percutaneous plate fixation of comminuted ulnar fractures
    Karistinos, A
    Olmedo, ML
    Albright, JA
    ORTHOPEDICS, 2005, 28 (11) : 1320 - 1321
  • [34] Pediatric Physeal Slide-traction Plate Fixation for Comminuted Distal Femur Fractures in Children
    Lin, Dasheng
    Lian, Kejian
    Hong, Jiayuan
    Ding, Zhenqi
    Zhai, Wenliang
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2012, 32 (07) : 682 - 686
  • [35] THE VALUE OF BRIDGING PLATE OSTEOSYNTHESIS IN COMMINUTED FRACTURES OF THE FEMUR
    HEITEMEYER, U
    HIERHOLZER, G
    TERHORST, J
    UNFALLCHIRURG, 1986, 89 (12): : 533 - 538
  • [36] BLADE-PLATE FIXATION IN NON-UNION AND IN COMPLICATED FRACTURES OF THE SUPRACONDYLAR REGION OF THE FEMUR
    ALTENBERG, AR
    SHORKEY, RL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1949, 31-A (02): : 312 - 316
  • [37] INTERNAL-FIXATION OF FRACTURES OF THE NECK OF THE FEMUR USING VONBAHR SCREWS AND ALLOWING IMMEDIATE WEIGHT BEARING - PROSPECTIVE CLINICAL-STUDY
    SOREIDE, O
    MOLSTER, A
    RAUGSTAD, TS
    OLERUD, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1979, 10 (03): : 239 - 244
  • [38] CLOSED INTRAMEDULLARY FIXATION OF SUPRACONDYLAR FRACTURES OF THE OSTEOPOROTIC FEMUR USING ENDERS NAILS
    EINODER, BJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (01): : 101 - 101
  • [39] SUPRACONDYLAR-INTERCONDYLAR FRACTURES OF THE FEMUR TREATED WITH A SUPRACONDYLAR PLATE AND LAG SCREW
    GILES, JB
    DELEE, JC
    HECKMAN, JD
    KEEVER, JE
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (06): : 864 - 870
  • [40] Indirect reduction and ''biological'' fixation of comminuted metaphyseal fractures of the femur
    Baumgaertel, F