The effective coefficient of secondary electron emission in plasma display panel

被引:0
|
作者
Hur, MS [1 ]
Lee, JK [1 ]
Kim, HC [1 ]
Kang, BK [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect Engn, Pohang 790784, South Korea
关键词
back-scattering; discharge; Paschen breakdown curve; plasma display; secondary electron; simulation;
D O I
暂无
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The effective secondary electron emission coefficient (SEEC) in a plasma display panel (PDP) is estimated by comparing the Paschen breakdown curves from simulations with the experiment. It is found that the effective SEEC in PDP is dependent on the ratio of electric field to pressure. The estimated values are 0.59 similar to0.79 for the pure Ne and 0.1 similar to0.13 for the Ne-Xe (96/4) mixture, respectively.
引用
收藏
页码:861 / 863
页数:3
相关论文
共 50 条
  • [31] Characteristics of a micro dielectric barrier discharge ignited by a cold cathode with high ion-induced secondary electron emission for plasma display panel
    Uchida, Giichiro
    Uchida, Satoshi
    Kajiyama, Hiroshi
    Shinoda, Tsutae
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (09)
  • [32] CALCULATION OF EFFECTIVE COEFFICIENT OF SECONDARY-ELECTRON EMISSION OF WALLS LOCALIZING A SUPERHIGH FREQUENCY DISCHARGE
    STANSKII, VA
    GANICHEV, DA
    FRIDRIKH.SA
    ZHURNAL TEKHNICHESKOI FIZIKI, 1973, 43 (08): : 1750 - 1752
  • [33] Secondary emission of dielectrics used in plasma display panels
    1600, American Institute of Physics Inc. (88):
  • [34] Secondary emission of dielectrics used in plasma display panels
    Auday, G
    Guillot, P
    Galy, J
    JOURNAL OF APPLIED PHYSICS, 2000, 88 (08) : 4871 - 4874
  • [35] THE SECONDARY-ELECTRON EMISSION COEFFICIENT OF DISORDERED SURFACES
    BOUCHARD, C
    CARETTE, JD
    SURFACE SCIENCE, 1980, 100 (01) : 241 - 250
  • [36] Dependence of Asperity Depth on Secondary Electron Emission Coefficient
    Fujita, Sho
    Iwao, Toru
    Yumoto, Motoshige
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 36 - 40
  • [37] Secondary electron emission coefficient of a MgO single crystal
    Choi, EH
    Lim, JY
    Kim, YG
    Ko, JJ
    Kim, DI
    Lee, CW
    Cho, GS
    JOURNAL OF APPLIED PHYSICS, 1999, 86 (11) : 6525 - 6527
  • [38] MEASUREMENT OF THE COEFFICIENT OF SECONDARY ELECTRON EMISSION WITH A RESONANT CAVITY
    SMITHER, RK
    PHYSICAL REVIEW, 1955, 99 (02): : 646 - 646
  • [39] An axisymmetric model for an RF plasma in contact with a surface having a nonuniform secondary electron emission coefficient
    Xu, WL
    Sides, PJ
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1996, 24 (03) : 1072 - 1078
  • [40] SECONDARY ELECTRON EMISSION AND EFFECTIVE ATOMIC NUMBERS
    HINE, GJ
    NUCLEONICS, 1952, 10 (01): : 9 - 15