Improving metrological characteristics of a frequency standard based on cesium atoms

被引:0
|
作者
Arinushkina, K. G. [1 ]
Valov, A. P. [2 ]
Davydov, V. V. [2 ,3 ]
机构
[1] Peter Great St Petersburg Polytech Univ, St Petersburg, Russia
[2] Bonch Bruevich St Petersburg State Univ Telecommun, St Petersburg, Russia
[3] All Russian Res Inst Phytopathol, Moscow, Moscow Region, Russia
关键词
time scale; stabilization; automatic frequency control; frequency stabilizer; cesi-um frequency standard; operational amplifier; atomic beam tube;
D O I
10.18721/JPM.153.220
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The necessity of constant modernization of quantum frequency standards (QFS) -atomic clocks, which are used in satellite navigation and telecommunication systems to solve new problems in terms of the speed of transmission of large amounts of information, etc., is substantiated. It is noted that among all atomic clocks, cesium QFSs occupy a special place. These standards are the primary frequency reference upon which the international time scale is based. The main goal of all QFS upgrades is to improve the metrological characteristics. In the case of its use on moving objects, its dimensions, weight and power consumption also become important characteristics. The article presents one of the options for reducing the influence of negative factors on the stability of the QFS. The problem of modernizing the cesium frequency standard by including a device for monitoring and stabilizing the temperature regime of its operation is considered.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [21] A method of improving the metrological characteristics of contactless conductometers
    Krivobokov, D. E.
    MEASUREMENT TECHNIQUES, 2007, 50 (05) : 543 - 547
  • [22] METROLOGICAL ANALYSIS OF TYPE MTS-3 CESIUM FREQUENCY REFERENCE
    ABASHEV, YG
    BARYSHEV, VN
    ELKIN, GA
    TIMOFEEV, YV
    POLYAKOVA, LI
    PUSHKIN, SB
    RUNOV, VY
    ULYANOV, AA
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (02): : 97 - 99
  • [23] A method of improving the metrological characteristics of contactless conductometers
    D. E. Krivobokov
    Measurement Techniques, 2007, 50 : 543 - 547
  • [24] A frequency standard based on a continuous beam of laser cooled atoms
    Berthoud, P
    Joyet, A
    Thomann, P
    Dudle, G
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 128 - 129
  • [25] Aspects of improving metrological characteristics of a sensor based on palladium nanoparticles for methionine determination
    Gorchakov, E. V.
    Perevezentseva, D. O.
    Vaitulevich, E. A.
    Dubinina, O. V.
    BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2025, 336 (01): : 70 - 79
  • [26] THE NIST OPTICALLY PUMPED CESIUM FREQUENCY STANDARD
    DRULLINGER, RE
    GLAZE, DJ
    LOWE, JL
    SHIRLEY, JH
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) : 162 - 164
  • [27] CESIUM BEAM FREQUENCY STANDARD FOR THE PLSS PROGRAM
    SILVERMETZ, D
    PASCARU, I
    MEIRS, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 128 - 129
  • [28] Progress in the LPTF cesium beam frequency standard
    Makdissi, A
    Berthet, JP
    de Clercq, E
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 16 - 17
  • [29] Atomic clock with cesium fountain frequency standard
    Bauch, A
    PTB-MITTEILUNGEN, 1998, 108 (01): : 3 - 18
  • [30] CESIUM BEAM FREQUENCY STANDARD CAVITY DESIGN
    MUNGALL, AG
    DAAMS, H
    METROLOGIA, 1970, 6 (02) : 60 - &