Soot reference materials for instrument calibration and intercomparisons: a workshop summary with recommendations

被引:161
|
作者
Baumgardner, D. [1 ]
Popovicheva, O. [2 ]
Allan, J. [3 ]
Bernardoni, V. [4 ,5 ]
Cao, J. [6 ]
Cavalli, F. [7 ]
Cozic, J. [8 ]
Diapouli, E. [9 ]
Eleftheriadis, K. [9 ]
Genberg, P. J. [10 ]
Gonzalez, C. [11 ]
Gysel, M. [12 ]
John, A. [13 ]
Kirchstetter, T. W. [14 ]
Kuhlbusch, T. A. J. [13 ,15 ]
Laborde, M. [12 ]
Lack, D. [16 ,17 ]
Mueller, T. [18 ]
Niessner, R. [19 ]
Petzold, A. [20 ]
Piazzalunga, A. [21 ,22 ]
Putaud, J. P. [7 ]
Schwarz, J. [16 ,17 ]
Sheridan, P. [16 ]
Subramanian, R. [23 ]
Swietlicki, E. [10 ]
Valli, G. [4 ,5 ]
Vecchi, R. [4 ,5 ]
Viana, M. [24 ]
机构
[1] Univ Nacl Autonoma Mexico, Ctr Ciencias Atmosfera, Mexico City 04510, DF, Mexico
[2] State Univ, Moscow, Russia
[3] Univ Manchester, Manchester, Lancs, England
[4] Univ Milan, Dept Phys, Milan, Italy
[5] Natl Inst Nucl Phys, Milan, Italy
[6] Chinese Acad Sci, Inst Earth Environm, Xian, Peoples R China
[7] Inst Environm & Sustainabil, Joint Res Ctr, European Commis, Ispra, Italy
[8] Lab Glaciol & Geophys Environm, St Martin Dheres, France
[9] NCSR Demokritos, Inst Nucl Technol & Radiat Protect, ERL, Athens 15310, Greece
[10] Lund Univ, Div Nucl Phys, S-22100 Lund, Sweden
[11] NIST, Gaithersburg, MD 20899 USA
[12] Paul Scherrer Inst, Lab Atmospher Chem, Villigen, Switzerland
[13] IUTA Ev, Air Qual & Sustainable Nanotechnol Unit, Duisburg, Germany
[14] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[15] Kings Coll London, Environm Res Grp, London WC2R 2LS, England
[16] NOAA, Earth Syst Res Lab, Boulder, CO USA
[17] Univ Colorado, Cooperat Inst Res Environm Sci, Boulder, CO 80309 USA
[18] Leibniz Inst Tropospher Res, Leipzig, Germany
[19] Tech Univ Munich, Munich, Germany
[20] Deutsch Zentrums Luft & Raumfahrt, Oberpfaffenhofen, Germany
[21] Univ Milano Bicocca, Dept Environm & Territorial Sci, Milan, Italy
[22] Univ Milan, Dept Inorgan Metallorgan & Analyt Chem, Milan, Italy
[23] RTI, Res Triangle Pk, NC USA
[24] Spanish Res Council CSIC, IDAEA CSIC Inst Environm Assessment & Water Res I, Barcelona, Spain
关键词
AEROSOL LIGHT-ABSORPTION; FILTER-BASED MEASUREMENTS; LASER-INDUCED INCANDESCENCE; BLACK CARBON; ELEMENTAL CARBON; PARTICULATE MATTER; DIFFUSION FLAME; ORGANIC-CARBON; DIESEL EXHAUST; PARTICLES;
D O I
10.5194/amt-5-1869-2012
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Soot, which is produced from biomass burning and the incomplete combustion of fossil and biomass fuels, has been linked to regional and global climate change and to negative health problems. Scientists measure the properties of soot using a variety of methods in order to quantify source emissions and understand its atmospheric chemistry, reactivity under emission conditions, interaction with solar radiation, influence on clouds, and health impacts. A major obstacle currently limiting progress is the absence of established standards or reference materials for calibrating the many instruments used to measure the various properties of soot. The current state of availability and practicability of soot standard reference materials (SRMs) was reviewed by a group of 50 international experts during a workshop in June of 2011. The workshop was convened to summarize the current knowledge on soot measurement techniques, identify the measurement uncertainties and limitations related to the lack of soot SRMs, and identify attributes of SRMs that, if developed, would reduce measurement uncertainties. The workshop established that suitable SRMs are available for calibrating some, but not all, measurement methods. The community of users of the single-particle soot-photometer (SP2), an instrument using laser-induced incandescence, identified a suitable SRM, fullerene soot, but users of instruments that measure light absorption by soot collected on filters did not. Similarly, those who use thermal optical analysis (TOA) to analyze the organic and elemental carbon components of soot were not satisfied with current SRMs. The workshop, and subsequent, interactive discussions, produced a number of recommendations for the development of new SRMs, and their implementation, that would be suitable for the different soot measurement methods.
引用
收藏
页码:1869 / 1887
页数:19
相关论文
共 50 条
  • [42] Biomedical Imaging Research Opportunities Workshop II: A Summary of Findings and Recommendations*
    William R. Hendee
    Annals of Biomedical Engineering, 2005, 33 : 988 - 990
  • [43] Biomedical imaging research opportunities workshop III: Summary of findings and recommendations
    Hendee, WR
    RADIOLOGY, 2006, 238 (02) : 402 - 404
  • [44] ADVANCING THE ADDITIVE MANUFACTURING WORKFORCE: SUMMARY AND RECOMMENDATIONS FROM A NSF WORKSHOP
    Williams, Christopher B.
    Simpson, Timothy W.
    Hripko, Michael
    INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2015, VOL 3, 2016,
  • [45] Recommendations for Enhancing Quality and Capability of Indian Biopharmaceutical Industry: Summary of a Workshop
    Uppal, Annu
    Koduri, Chaitanya Kumar
    Yadlapalli, Sireesha
    Chirmule, Narendra
    Chakrabarti, Ranjan
    Atouf, Fouad
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 109 (10) : 2958 - 2961
  • [46] Report: Summary of the workshop ''aspects of high-precision radiocarbon calibration''
    Kromer, B
    Ambers, J
    Baillie, MGL
    Damon, PE
    Hesshaimer, V
    Hofmann, J
    Joris, O
    Levin, I
    Manning, SW
    McCormac, FG
    vanderPlicht, J
    Spurk, M
    Stuiver, M
    Weninger, B
    RADIOCARBON, 1996, 38 (03) : 607 - 610
  • [47] HETEROSCEDASTIC CALIBRATION USING ANALYZED REFERENCE MATERIALS AS CALIBRATION STANDARDS
    WATTERS, RL
    CARROLL, RJ
    SPIEGELMAN, CH
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03): : 264 - 265
  • [48] Satellite instrument calibration for measuring global climate change - Report of a Workshop
    Ohring, G
    Wielicki, B
    Spencer, R
    Emery, B
    Datla, R
    BULLETIN OF THE AMERICAN METEOROLOGICAL SOCIETY, 2005, 86 (09) : 1303 - +
  • [49] Calibration in the field of materials engineering as instrument of quality assurance
    Gerber, S.
    Ellermeier, J.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2018, 49 (01) : 5 - 11
  • [50] WORKSHOP ON THE X-RAY-FLUORESCENCE OF LEAD IN BONE - CONCLUSIONS, RECOMMENDATIONS AND SUMMARY
    TODD, AC
    LANDRIGAN, PJ
    BLOCH, P
    NEUROTOXICOLOGY, 1993, 14 (01) : 145 - 154