Influence of organ at risk definition on rectal dose-volume histograms in patients with prostate cancer undergoing external-beam radiotherapy

被引:0
|
作者
Boehmer, D
Kuczer, D
Badakhshi, H
Stiefel, S
Kuschke, W
Wernecke, KD
Budach, V
机构
[1] Univ Clin Charite, Dept Radiat Oncol, Berlin, Germany
[2] Univ Clin Charite, Dept Med Phys, Berlin, Germany
[3] Charite, Dept Med Biometry, Berlin, Germany
关键词
prostate cancer; radiotherapy; dose-volume histogram; organ at risk definition; rectal contouring;
D O I
10.1007/s00066-006-1462-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate rectal close-volume relations during three-dimensional conformal radiotherapy of patients with prostate cancer by means of different rectal volume contours. Patients and Methods: 55 patients with prostate cancer underwent three-dimensional conformal external-beam radiotherapy. Rectal dose-volume histograms were calculated for four separately contoured rectal volumes in all patients resulting in four groups. In group 1 the outer rectal wall was contoured two CT slices above and below the planning target volume. The rectal contour of group 2 was drawn from the anal verge up to the sigmoid. Furthermore, the posterior half of the rectum was contoured for both volumes mentioned above (groups 1a and 2a). Statistical analysis was then performed using nonparametric WiLcoxon tests. Results: The mean target dose was 72.9 Gy (standard deviation [SD] +/- 2.1 Gy). The minimum target dose was 70.2 Gy. Mean rectum dose ( SD) over all patients was 50.7 Gy (+/- 4.6 Gy), 45.2 Gy (+/- 5.4 Gy), 43.2 Gy (+/- 4.2 Gy), and 38.7 Gy (+/- 5.5 Gy) for group 1, 2, la, and 2a, respectively. The corresponding volumes receiving >= 70 Gy for groups 1 and 2 were 14.0% (+/- 5.3%) and 11.9% ( +/- 4.5%). These differences were statistically significant. Comparison of minimum and mean rectal dose also revealed a statistically significant difference toward higher doses in groups 1 and 1a (p < 0.001). Maximum rectal doses for groups 1 and 2 as well as for groups la and 2a revealed no statistically significant difference (p = 1.0). Conclusion: Data from the literature on normal-tissue complication probability (rectal bleeding) refer to different rectal contours. When applying dose restrictions to the rectum, contouring becomes a significant factor that determines the risk of rectal toxicity. The results of this study show that different ways of rectal contouring significantly influence doses to the rectum. The influence of organ at risk contouring should be considered thoroughly in conformal radiotherapy of prostate cancer patients, especially in dose escalation studies. It is recommended to calculate the doses for absolute rectal volumes and correlate these data with toxicity in order to be able to achieve comparable results among different institutions.
引用
收藏
页码:277 / 282
页数:6
相关论文
共 50 条
  • [41] Dose/volume relationship of late rectal bleeding after external beam radiotherapy for localized prostate cancer: Absolute or relative rectal volume?
    Kupelian, PA
    Reddy, CA
    Carlson, TP
    Willoughby, TR
    CANCER JOURNAL, 2002, 8 (01): : 62 - 66
  • [42] Impact of double-balloon rectal catheter use in external-beam radiotherapy for prostate cancer
    Kenji Takayama
    Takashi Mizowaki
    Yoshiharu Negoro
    Yoshiki Norihisa
    Masahiro Hiraoka
    International Journal of Clinical Oncology, 2011, 16 : 50 - 56
  • [43] Impact of mean rectal dose on late rectal bleeding after conformal radiotherapy for prostate cancer:: Dose-volume effect
    Zapatero, A
    García-Vicente, F
    Modolell, I
    Alcántara, P
    Floriano, A
    Cruz-Conde, A
    Torres, JJ
    Pérez-Torrubia, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (05): : 1343 - 1351
  • [44] Evidence-based Definition of a "Safe" Dose-volume Curve for Reducing Rectal Toxicity from External Beam Prostate Radiation Therapy
    Yaparpalvi, R.
    Garg, M.
    Hannan, R.
    Shen, J.
    Lee, C.
    Landau, E.
    Bodner, W.
    Mah, D.
    Guha, C.
    Kalnicki, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S384 - S384
  • [46] A cylindrical model of the rectum: comparing dose-volume, dose-surface and dose-wall histograms in the radiotherapy of prostate cancer
    Fiorino, C
    Gianolini, S
    Nahum, AE
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (16): : 2603 - 2616
  • [47] Conformal irradiation of the prostate: Estimating long-term rectal bleeding risk using dose-volume histograms
    Hartford, AC
    Niemierko, A
    Adams, JA
    Urie, MM
    Shipley, WU
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (03): : 721 - 730
  • [48] Surgery, brachytherapy, and external-beam radiotherapy for early prostate cancer
    Peschel, RE
    Colberg, JW
    LANCET ONCOLOGY, 2003, 4 (04): : 233 - 241
  • [49] Randomized Trial of Hypofractionated External-Beam Radiotherapy for Prostate Cancer
    Pollack, Alan
    Walker, Gail
    Horwitz, Eric M.
    Price, Robert
    Feigenberg, Steven
    Konski, Andre A.
    Stoyanova, Radka
    Movsas, Benjamin
    Greenberg, Richard E.
    Uzzo, Robert G.
    Ma, Charlie
    Buyyounouski, Mark K.
    JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (31) : 3860 - +
  • [50] An external validation of the Candiolo nomogram in a cohort of prostate cancer patients treated by external-beam radiotherapy
    Gabriele, Domenico
    Guarneri, Alessia
    Bartoncini, Sara
    Munoz, Fernando
    Tamponi, Matteo
    Russo, Filippo
    Stamatakos, Georgios
    Guiot, Caterina
    Regge, Daniele
    Ricardi, Umberto
    RADIATION ONCOLOGY, 2021, 16 (01)