Seismic performance of bolted beam-to-column connection with rib-stiffened splicing plate

被引:18
|
作者
Liu, Xue-Chun [1 ,2 ]
Wang, Yue [1 ]
Cui, Xiao-Xiong [1 ]
Yu, Cheng [3 ]
Bai, Zheng-Xian [1 ,2 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] Univ North Texas, Dept Engn Technol, Denton, TX 76207 USA
基金
中国国家自然科学基金;
关键词
Full-bolted connection; Beam-to-column connection; Rib-stiffened splicing plate; Seismic performance; Trapezoidal stiffener; On-site assembly; MOMENT CONNECTIONS; CYCLIC BEHAVIOR; STEEL; JOINTS; BUILDINGS; DESIGN;
D O I
10.1016/j.jcsr.2020.106300
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A bolted beam-to-column connection with rib-stiffened splicing plates is presented to facilitate on-site assembly and enhance the stiffness of joints. The joints consist of three modules and are assembled using bolts on site. Cyclic tests and a finite element analysis (FEA) are performed on seven full-scale joints. The influence of the trapezoidal stiffener's size, end-plate connection type, and the number of bolts on the seismic performance of the joints is investigated. The seismic performance of the bolted joints is compared with that of a welded joint. The failure mode, hysteretic curve, energy dissipation capacity, ductility, rotation capacity, bolt tension, friction, strength, and stiffness of the joints are determined via the tests and FEA. The trapezoidal stiffener significantly improves the bearing capacity, stiffness, and energy-dissipation capacity of the joints, making the plastic hinge occur on the beam flange outside the splicing zone. It is preferable to move the web bolts to the beam flange for improved seismic performance. The bolts on the four corners of the column flange have little effect on the seismic performance; thus, the bolts can be eliminated and the flange can be substituted by four small plates to reduce cost. This reasonable design could prevent the slipping of the joint during small-magnitude earthquakes, facilitate energy dissipation via slip during medium-magnitude earthquakes, and facilitate energy dissipation via the slip and plastic deformation of the beams during large-magnitude earthquakes. The formula for the ultimate load is presented, and the corresponding calculation results agree well with the test results. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Numerical analysis of a prefabricated concrete beam-to-column connection with bolted end plates
    Zhang, Hao
    Huang, Wei
    Liu, Bolong
    Li, Shufeng
    Li, Qingning
    Mao, Lu
    STRUCTURES, 2024, 59
  • [22] A new form of high moment capacity bolted steel beam-to-column connection
    Yeung, KW
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 311 - 318
  • [23] Comparative experimental studies on the web cleat bolted CFS beam-to-column connection
    Natesan, Vijayakumar
    Shanmugasundaram, Bharath
    Madhavan, Mahendrakumar
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170
  • [24] Behavior of beam-to-column connection of CFT column system under seismic force
    Fujimoto, T
    Inai, E
    Tokinoya, H
    Kai, M
    Mori, K
    Mori, O
    Nishiyama, I
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 557 - 564
  • [25] Sound absorption of a rib-stiffened plate covered by anechoic coatings
    20151200669968
    Liu, Bilong (liubl@mail.ioa.ac.cn), 1600, Acoustical Society of America (137):
  • [26] Sound absorption of a rib-stiffened plate covered by anechoic coatings
    Fu, Xinyi
    Jin, Zhongkun
    Yin, Yao
    Liu, Bilong
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2015, 137 (03): : 1551 - 1556
  • [27] Sound generated by a vortex interacting with a rib-stiffened elastic plate
    Shah, PL
    Howe, MS
    JOURNAL OF SOUND AND VIBRATION, 1996, 197 (01) : 103 - 115
  • [28] Seismic behavior of bolted beam-to-column connections for concrete filled steel tube
    Wu, LY
    Chung, LL
    Tsai, SF
    Shen, TJ
    Huang, GL
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2005, 61 (10) : 1387 - 1410
  • [29] Experimental study on seismic behavior of the damage-control steel plate fuses for beam-to-column connection
    Lin, Xuchuan
    Li, Hang
    He, Liusheng
    Zhang, Lingxin
    ENGINEERING STRUCTURES, 2022, 270
  • [30] Cold-formed steel beam-to-column bolted connections for seismic applications
    Papargyriou, Ioannis
    Mojtabaei, Seyed Mohammad
    Hajirasouliha, Iman
    Becque, Jurgen
    Pilakoutas, Kypros
    THIN-WALLED STRUCTURES, 2022, 172