Seismic performance of bolted beam-to-column connection with rib-stiffened splicing plate

被引:18
|
作者
Liu, Xue-Chun [1 ,2 ]
Wang, Yue [1 ]
Cui, Xiao-Xiong [1 ]
Yu, Cheng [3 ]
Bai, Zheng-Xian [1 ,2 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
[3] Univ North Texas, Dept Engn Technol, Denton, TX 76207 USA
基金
中国国家自然科学基金;
关键词
Full-bolted connection; Beam-to-column connection; Rib-stiffened splicing plate; Seismic performance; Trapezoidal stiffener; On-site assembly; MOMENT CONNECTIONS; CYCLIC BEHAVIOR; STEEL; JOINTS; BUILDINGS; DESIGN;
D O I
10.1016/j.jcsr.2020.106300
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A bolted beam-to-column connection with rib-stiffened splicing plates is presented to facilitate on-site assembly and enhance the stiffness of joints. The joints consist of three modules and are assembled using bolts on site. Cyclic tests and a finite element analysis (FEA) are performed on seven full-scale joints. The influence of the trapezoidal stiffener's size, end-plate connection type, and the number of bolts on the seismic performance of the joints is investigated. The seismic performance of the bolted joints is compared with that of a welded joint. The failure mode, hysteretic curve, energy dissipation capacity, ductility, rotation capacity, bolt tension, friction, strength, and stiffness of the joints are determined via the tests and FEA. The trapezoidal stiffener significantly improves the bearing capacity, stiffness, and energy-dissipation capacity of the joints, making the plastic hinge occur on the beam flange outside the splicing zone. It is preferable to move the web bolts to the beam flange for improved seismic performance. The bolts on the four corners of the column flange have little effect on the seismic performance; thus, the bolts can be eliminated and the flange can be substituted by four small plates to reduce cost. This reasonable design could prevent the slipping of the joint during small-magnitude earthquakes, facilitate energy dissipation via slip during medium-magnitude earthquakes, and facilitate energy dissipation via the slip and plastic deformation of the beams during large-magnitude earthquakes. The formula for the ultimate load is presented, and the corresponding calculation results agree well with the test results. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Experimental study of beam-to-column connection with bolted joints
    Koyama, Y.
    Sato, A.
    Idota, H.
    Sato, Y.
    Yagi, S.
    Takaki, S.
    Kamada, M.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 638 - 645
  • [2] Seismic behavior of precast concrete beam-to-column connection with double box bolted couplers
    Zhang, Hao
    Huang, Wei
    Li, Jiashen
    Quan, Wenli
    ENGINEERING STRUCTURES, 2025, 326
  • [3] Experimental study on beam-to-column clip angle bolted connection
    Natesan, Vijayakumar
    Madhavan, Mahendrakumar
    THIN-WALLED STRUCTURES, 2019, 141 : 540 - 553
  • [4] Behaviour of steel end plate bolted beam-to-column joints
    Qureshi, J.
    Shrestha, S.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 944 - 949
  • [5] Behaviour of steel end plate bolted beam-to-column joints
    Qureshi, J.
    Shrestha, S.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 329 - 330
  • [6] ANALYSIS OF BEAM-TO-COLUMN BOLTED FLUSH END PLATE CONNECTIONS
    Foces, Antonio
    Garrido, Jose Antonio
    Moreno, Alicia
    REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2007, 23 (01): : 35 - 53
  • [7] Seismic performance of bolted connection of H-beam to HSS-column with web end-plate
    Liu, Xue Chun
    Cui, Fu Yuan
    Zhan, Xin Xin
    Yu, Cheng
    Jiang, Zi Qin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 156 : 167 - 181
  • [8] Seismic performance of a square HSS column to H-section beam bolted connection with double cover plate
    Zhan, Xin-Xin
    Liu, Xue-Chun
    Feng, Shuo
    Yu, Cheng
    ENGINEERING STRUCTURES, 2021, 231 (231)
  • [9] NUMERICAL INVESTIGATION ON SEISMIC PERFORMANCE OF PREFABRICATED STEEL BEAM-TO-COLUMN CONNECTION WITH REPLACEABLE U-SHAPED PLATE
    Zhang, Xun
    Zhou, Bin
    Gao, Jun-Dong
    Qian, Hui
    Song, Lian-Zhi
    Cai, Li-Ming
    ADVANCED STEEL CONSTRUCTION, 2024, 20 (04): : 397 - 405
  • [10] Seismic Performance of Precast Steel Beam-Column Joint with Bolted Connection
    Chen, Yandan
    Lu, Yonggang
    Liu, Tong
    BUILDINGS, 2024, 14 (08)