An investigation into a treatment strategy for the Berg River water at the Voelvlei water treatment plant

被引:0
|
作者
Swarts, R. J. [1 ]
Schoeman, J. J. [2 ]
机构
[1] City Cape Town, Sci Serv Branch, ZA-7764 Cape Town, South Africa
[2] Univ Pretoria, Dept Chem Engn, Water Utilisat Div, ZA-0002 Pretoria, South Africa
来源
关键词
aluminium sulphate; Berg River water; ferric sulphate; jar tests; treatment strategy; Voelvlei raw water;
D O I
10.2166/ws.2011.118
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main aim of this study was to determine a treatment strategy for the Berg River water at the Voelviei water treatment plant (WTP). Jar tests were conducted using ferric and aluminium sulphate as coagulants to determine the optimum treatment parameters of the Berg River water and the Voelvlei WTP raw water. The results for the Voelvlei WTP raw water and the Berg River water with ferric sulphate as the coagulant showed an optimum Fe3+ dosage of 3.0-4.0 mg/L and 4.0-6.0 mg/L, respectively, with an optimum coagulation pH range of 6.6-9.5 and 5.0-10.0, respectively. The results with aluminium sulphate as the coagulant showed an optimum Al3+ dosage of 2.5-3.0 mg/L and 4.0-5.0 mg/L, respectively, with an optimum coagulation pH of 6.0-7.0 and 6.0, respectively. This study concluded that the Berg River water cannot be effectively treated at the Voelvlei WTP using the plants treatment parameters, even if it is blended with the Voelviei WTP raw water. The best treatment strategy for the Berg River water would be pre-treatment using either ferric sulphate or the MIEX (R) resin on its own, or in conjunction with one another.
引用
收藏
页码:56 / 64
页数:9
相关论文
共 50 条
  • [31] Research on enhanced coagulation test for sludge water recycling in water treatment plant in Ganjiang River Nanchang Section
    Tong, Zhengong
    Fu, Longwang
    Li, Jun
    Kang, Caixia
    Wu, Zheshuai
    Zhong, Cilong
    DESALINATION AND WATER TREATMENT, 2021, 232 : 9 - 15
  • [32] WATER TREATMENT-PLANT AUTOMATION
    不详
    WATER SERVICES, 1980, 84 (1015): : 567 - 567
  • [33] Potable water treatment plant for Dili
    Prasad, Kris
    Momose, Kazufumi
    Civil Engineers Australia, 2003, 75 (10): : 28 - 29
  • [34] WASTE WATER TREATMENT PLANT EQUIPMENT
    Miholic, Tina
    HRVATSKE VODE, 2010, 18 (74) : 359 - 360
  • [35] Modeling and control of a water treatment plant
    Villa, JL
    Duque, M
    Gauthier, A
    Rakoto-Ravalontsalama, N
    2003 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOLS 1-5, CONFERENCE PROCEEDINGS, 2003, : 171 - 176
  • [36] Samsung sells water treatment plant
    不详
    CHEMICAL & ENGINEERING NEWS, 2000, 78 (20) : 18 - 18
  • [37] Ferrocement for water treatment plant ship
    Youzhen, Huang, 1600, (19):
  • [38] Water treatment plant seismic upgrades
    Lee, D
    Mo, B
    Zimmerman, T
    ANTI-SEISMIC MEASURES ON WATER SUPPLY, 2000, 18 (03): : 136 - 146
  • [39] Water treatment plant residuals management
    Dharmappa, HB
    Hasia, A
    Hagare, P
    WATER SCIENCE AND TECHNOLOGY, 1997, 35 (08) : 45 - 56
  • [40] WATER TREATMENT-PLANT SLUDGES
    不详
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1977, 69 (04): : 71 - 71