Peripheral contrast-enhanced MR angiography at 3.0T, improved spatial resolution and low dose contrast: initial clinical experience

被引:27
|
作者
Nael, Kambiz [1 ]
Krishnam, Mayil [1 ]
Nael, Ali [1 ]
Ton, Anthony [1 ]
Ruehm, Stefan G. [1 ]
Finn, J. Paul [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
关键词
Peripheral MRA; 3; 0T or high magnetic field; Multi-coil technology; Low dose contrast; Atherosclerosis;
D O I
10.1007/s00330-008-1074-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate a high spatial resolution peripheral contrast-enhanced MR angiography (CE-MRA) protocol, applying a dedicated multi-channel array coil and accelerated parallel acquisition at 3.0T in evaluation of patients with peripheral vascular disease. Twenty patients with peripheral vascular disease underwent multi-station high spatial resolution peripheral CE-MRA at 3T. The image quality, presence of venous contamination, image noise, and artifact were evaluated by 2 radiologists independently. Assessment of arterial disease for 540 arterial segments was performed, and findings were correlated with conventional catheter angiography in 10 patients. All studies were yielded high diagnostic image quality. Venous contamination and artifact were minimal and never interfered with diagnosis. Sixty seven arterial segments with significant stenoses (> 0%) were detected by observers with excellent interobserver agreement (kappa=0.82; 95% CI: 0.76, 0.88). There was a significant correlation between CE-MRA and conventional angiography (R=0.91 and 0.94 for reader 1 and 2, respectively) for the assessment of the degree of stenosis. Higher available SNR at 3T in combination with multi-coil technology and accelerated parallel acquisition, result in acquisition of nearly isotropic submillimeter 3D voxels throughout the entire peripheral arterial tree with diagnostic image quality and favorable comparative analysis with catheter angiography.
引用
收藏
页码:2893 / 2900
页数:8
相关论文
共 50 条
  • [41] Comparison of 1.5 and 3.0 T for Contrast-Enhanced Pulmonary Magnetic Resonance Angiography
    Londy, Frank Joseph
    Lowe, Suzan
    Stein, Paul D.
    Weg, John G.
    Eisner, Robert L.
    Leeper, Kenneth V.
    Woodard, Pamela K.
    Sostman, H. Dirk
    Jablonski, Kathleen A.
    Fowler, Sarah E.
    Hales, Charles A.
    Hull, Russell D.
    Gottschalk, Alexander
    Naidich, David P.
    Chenevert, Thomas L.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2012, 18 (02) : 134 - 139
  • [42] Free-Breathing High-Spatial-Resolution Delayed Contrast-Enhanced Three-Dimensional Viability MR Imaging of the Myocardium at 3.0T: A Feasibility Study
    Amano, Yasuo
    Matsumura, Yoshio
    Kumita, Shinichiro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1361 - 1367
  • [43] Clinical value of classification of venous malformations with contrast-enhanced MR Angiography
    Razek, Ahmed Abdel Khalek Abdel
    Albair, Germeen Ashmalla
    Samir, Sieza
    PHLEBOLOGY, 2017, 32 (09) : 628 - 633
  • [44] Evaluation of vascular complications of pancreas transplantation with high-spatial-resolution contrast-enhanced MR angiography
    Hagspiel, Klaus D.
    Nandalur, Kiran
    Pruett, Timothy L.
    Leung, Daniel A.
    Angle, J. Fritz
    Spinosa, David J.
    Matsumoto, Alan H.
    Ahmed, Hossam
    Sanfey, Hilary A.
    Sawyer, Robert G.
    Burkholder, Brian
    Brayman, Kenneth L.
    RADIOLOGY, 2007, 242 (02) : 590 - 599
  • [45] 3D high temporal and spatial resolution contrast-enhanced MR angiography of the whole brain
    Haider, Clifton R.
    Hu, Houchun Harry
    Campeau, Norbert G.
    Huston, John, III
    Riederer, Stephen J.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) : 749 - 760
  • [46] Increased Volume of Coverage for Abdominal Contrast-Enhanced MR Angiography with Two-Dimensional Autocalibrating Parallel Imaging: Initial Experience at 3.0 Tesla
    Lum, Darren P.
    Busse, Reed F.
    Francois, Christopher J.
    Brau, Anja C.
    Beatty, Philip J.
    Huff, Joshua
    Brittain, Jean H.
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1093 - 1100
  • [47] High-spatial-resolution contrast-enhanced MR angiography of the renal arteries: A prospective comparison with digital subtraction angiography
    Fain, SB
    King, BF
    Breen, JF
    Kruger, DG
    Riederer, SJ
    RADIOLOGY, 2001, 218 (02) : 481 - 490
  • [48] Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T
    D Dey
    A Schuhbaeck
    Q Yang
    Z Fan
    G Germano
    S Achenbach
    D Li
    P Slomka
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [49] High resolution contrast-enhanced MR angiography evaluation of rabbit carotid artery
    Wu, RH
    Spellman, MJ
    Kallmes, DF
    Christopher, JM
    Mugler, JP
    Short, JG
    RADIOLOGY, 1999, 213P : 274 - 274
  • [50] High resolution contrast-enhanced MR angiography in the evaluation of rabbit carotid artery
    Wu, RH
    Kallmes, DF
    RIVISTA DI NEURORADIOLOGIA, 2005, 18 (5-6): : 529 - 536