Fabrication of Au/ZnO/MWCNTs electrode and its characterization for electrochemical cholesterol biosensor

被引:23
|
作者
Kaariz, Davood Ghanei Agh [1 ]
Darabi, Elham [1 ]
Elahi, Seyed Mohammad [1 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Phys, Sci & Res Branch, Tehran, Iran
关键词
Electrochemical biosensor; Cholesterol; Cholesterol oxidase; Au nanoparticles; ZnO nanoparticles; Multi-wall carbon nanotubes; Au; ZnO; MWCNTs nanocomposite; CARBON NANOTUBES; ACID;
D O I
10.1007/s40094-020-00390-5
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this work, a new sensitive enzyme-based electrode for electrochemical cholesterol biosensor was fabricated based on a nanocomposite of Au nanoparticles, ZnO nanoparticles and multi-wall carbon nanotubes (Au/ZnO/MWCNTs). The nanocomposite was prepared by sol-gel method and deposited on FTO substrate by dip coating, followed by cholesterol oxidase (ChOx) enzyme immobilized (ChOx/Au/ZnO/MWCNTs). Structural properties and morphology of the nanocomposite have been studied using X-ray diffraction (XRD) and Field emission scanning electron microscopy (FESEM). The sample was subjected to Fourier transform infrared spectroscopy (FTIR) to determine functional groups. Electrochemical behavior of the electrode was studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques as a function of cholesterol concentration. Electrochemical impedance spectroscopy (EIS) was also considered to study of surface modified electrodes. The ChOx/Au/ZnO/MWCNTs electrode has been found to have enhanced electron transfer and display excellent analytical linear performances. The fabricated electrode exhibited low detection limit (0.1 mu M), high sensitivity (25.89 mu A/mu M) evaluated from DPV data in the detection range of 0.1-100 mu M and high selectivity in the determination of cholesterol over glucose and uric acid. The application of the ChOx/Au/ZnO/MWCNTs electrode in detection of cholesterol in human serum was also confirmed.
引用
收藏
页码:339 / 348
页数:10
相关论文
共 50 条
  • [11] α-Amylase Monitoring by a Novel Amperometric Biosensor Based on Au Electrode: Its Optimization, Characterization, and Application
    Mengulluoglu, Umut
    Altug, Cagri
    Ertugrul, H. Deniz
    Yildiz, Abdulkerim
    Ekici, E. Melis
    Dinckaya, Erhan
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2012, 40 (1-2): : 97 - 102
  • [12] Electrochemical characterization of the underpotential deposition of tellurium on Au electrode
    Zhu, W.
    Yang, J. Y.
    Zhou, D. X.
    Bao, S. Q.
    Fan, X. A.
    Duan, X. K.
    ELECTROCHIMICA ACTA, 2007, 52 (11) : 3660 - 3666
  • [13] Electrochemical DNA biosensor fabrication with hollow gold nanospheres modified electrode and its enhancement in DNA immobilization and hybridization
    Liu, Shufeng
    Liu, Jing
    Han, Xiaoping
    Cui, Yanning
    Wang, Wei
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (07): : 1640 - 1645
  • [14] Rapid fabrication of a nano interdigitated array electrode and its amperometric characterization as an electrochemical sensor
    Samarao, Ashwin K.
    Rust, Michael J.
    Ahn, Chong H.
    2007 IEEE SENSORS, VOLS 1-3, 2007, : 644 - 647
  • [15] Fabrication of an electrochemical biosensor with ZnO nanoflakes interface for methylglyoxal quantification in food samples
    Jayaprakasan, Amudha
    Thangavel, Amarnath
    Bhat, Lakshmishri Ramachandra
    Gumpu, Manju Bhargavi
    Nesakumar, Noel
    Babu, K. Jayanth
    Vedantham, Srinivasan
    Rayappan, John Bosco Balaguru
    FOOD SCIENCE AND BIOTECHNOLOGY, 2018, 27 (01) : 9 - 17
  • [16] Fabrication of an electrochemical biosensor with ZnO nanoflakes interface for methylglyoxal quantification in food samples
    Amudha Jayaprakasan
    Amarnath Thangavel
    Lakshmishri Ramachandra Bhat
    Manju Bhargavi Gumpu
    Noel Nesakumar
    K. Jayanth Babu
    Srinivasan Vedantham
    John Bosco Balaguru Rayappan
    Food Science and Biotechnology, 2018, 27 : 9 - 17
  • [17] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    ANALYST, 1994, 119 (11) : 2331 - 2336
  • [18] Fabrication of ZnO nanorod modified electrode and its application to the direct electrochemical determination of hemoglobin and cytochrome c
    Zhang, CL
    Liu, MC
    Li, P
    Xian, YZ
    Cheng, YX
    Zhang, FF
    Wang, XL
    Jin, LT
    CHINESE JOURNAL OF CHEMISTRY, 2005, 23 (02) : 144 - 148
  • [19] Silica-Polyaniline Based Bienzyme Cholesterol Biosensor: Fabrication and Characterization
    Manesh, Kalayil Manian
    Santhosh, Padmanabhan
    Gopalan, Anantha Iyengar
    Lee, Kwang-Pill
    ELECTROANALYSIS, 2010, 22 (20) : 2467 - 2474
  • [20] Amperometric cholesterol biosensor based on cholesterol oxidase and Pt-Au/ MWNTs modified glassy carbon electrode
    Haritha, V. S.
    Kumar, S. R. Sarath
    Rakhi, R. B.
    MATERIALS TODAY-PROCEEDINGS, 2022, 50 : 34 - 39