Compressor-specific design of a single stage pulse tube refrigerator

被引:0
|
作者
Pfotenhauer, JM [1 ]
Baik, JH [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
来源
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A single stage active valve pulse tube refrigerator has been designed to operate at 30 K and provide a nominal cooling power in excess of 30 watts. This report details the various considerations comprising the system design, focusing on the limitations imposed by the reciprocating-type compressor commonly used for GM-style pulse tube refrigerators. We describe a design method for GM-style pulse tubes to maximize the pulse tube cooling power that can be produced from a compressor of fixed capacity. The method provides a physical understanding of the various influencing factors, and is illustrated using the specifications for the Cryomech CP640 compressor, which draws a maximum electrical power of 5.5 kW. The design process begins by defining mass flow and compressor work as a function of the discharge and suction pressures, thereby producing a compressor performance map. The compressor map in turn provides a framework from which the pulse tube system geometry can be optimized for maximum cooling power. Various real constraints, such as pressure drop through the valves and regenerator, laminar boundary layer along the pulse tube walls, and conduction losses are included in the design process and are shown to significantly impact the optimized result.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [11] 30-50 K single stage pulse tube refrigerator for HTS applications
    Yuan, J
    Maguire, J
    Sidi-Yekhlef, A
    Winn, P
    CRYOCOOLERS 11, 2001, : 235 - 241
  • [12] Step piston linear compressor for step piston type pulse tube refrigerator
    Xu, Sheng
    Wang, Chenguang
    Li, Yuanjian
    Dai, Haibin
    Liu, Zhifei
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 171 : 180 - 190
  • [13] Experimental Investigation of Superconducting Linear Compressor (SCLC) for Pulse Tube Refrigerator (PTR)
    Park, Jiho
    Park, Inmyong
    Cha, Jeongmin
    Jeong, Sangkwon
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [14] ANALYSIS OF DOUBLE INLET PULSE TUBE REFRIGERATOR WITH A VALVELESS STEPPED PISTON COMPRESSOR
    WU, PY
    ZHU, SW
    CHEN, ZQ
    CRYOGENICS, 1990, 30 : 253 - 256
  • [15] A SINGLE STAGE DOUBLE INLET PULSE TUBE REFRIGERATOR CAPABLE OF REACHING 42K
    ZHU, SW
    WU, PY
    CHEN, ZQ
    ZHU, WX
    ZHOU, YA
    CRYOGENICS, 1990, 30 : 257 - 261
  • [16] Optimal pulse tube volume design in GM-type pulse tube refrigerator
    Jung, Jeheon
    Jeong, Sangkwon
    CRYOGENICS, 2007, 47 (9-10) : 510 - 516
  • [17] Experimental Investigation and Thermoacoustic Analysis of a Single-Stage Pulse Tube Refrigerator with an Active Displacer
    Ying, Kongkuai
    Jiang, Zhenhua
    Yin, Wang
    Song, Jiantang
    Liu, Shaoshuai
    Zhu, Haifeng
    Li, Nanxi
    Wu, Yinong
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2023, 210 (3-4) : 514 - 535
  • [18] DEVELOPMENT OF A SINGLE-STAGE PULSE TUBE REFRIGERATOR CAPABLE OF REACHING 49-K
    LIANG, J
    ZHOU, Y
    ZHU, W
    CRYOGENICS, 1990, 30 (01) : 49 - 51
  • [19] Experimental study on the design of orifice pulse tube refrigerator
    Huang, BJ
    Yu, GJ
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (05): : 400 - 408
  • [20] The experimental investigation of a two-stage pulse tube refrigerator
    Wang, C
    Ju, YL
    Zhou, Y
    CRYOGENICS, 1996, 36 (08) : 605 - 609