Compressor-specific design of a single stage pulse tube refrigerator

被引:0
|
作者
Pfotenhauer, JM [1 ]
Baik, JH [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
来源
关键词
D O I
暂无
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A single stage active valve pulse tube refrigerator has been designed to operate at 30 K and provide a nominal cooling power in excess of 30 watts. This report details the various considerations comprising the system design, focusing on the limitations imposed by the reciprocating-type compressor commonly used for GM-style pulse tube refrigerators. We describe a design method for GM-style pulse tubes to maximize the pulse tube cooling power that can be produced from a compressor of fixed capacity. The method provides a physical understanding of the various influencing factors, and is illustrated using the specifications for the Cryomech CP640 compressor, which draws a maximum electrical power of 5.5 kW. The design process begins by defining mass flow and compressor work as a function of the discharge and suction pressures, thereby producing a compressor performance map. The compressor map in turn provides a framework from which the pulse tube system geometry can be optimized for maximum cooling power. Various real constraints, such as pressure drop through the valves and regenerator, laminar boundary layer along the pulse tube walls, and conduction losses are included in the design process and are shown to significantly impact the optimized result.
引用
收藏
页码:249 / 257
页数:9
相关论文
共 50 条
  • [1] Development of a single stage pulse tube refrigerator with linear compressor
    Yuan, J
    Maguire, J
    CRYOCOOLERS 13, 2005, : 157 - 163
  • [2] Experimental studies of convection in a single stage pulse tube refrigerator
    Kasthurirengan, S
    Jacob, S
    Karunanithi, R
    Behera, U
    Nadig, DS
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1474 - 1481
  • [3] Effect of impedance on a compressor driving pulse tube refrigerator
    Zhang, A. K.
    Wu, Y. N.
    Liu, S. S.
    Zhu, H. F.
    Zeng, Y. P.
    Jiang, Z. H.
    Kan, A. K.
    APPLIED THERMAL ENGINEERING, 2017, 124 : 688 - 694
  • [4] Experimental results of a single stage linear orifice pulse tube refrigerator
    Ishimura, M
    Bodegom, E
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1965 - 1972
  • [5] Design of a miniature pulse tube refrigerator
    Halouane, A
    Marechal, JC
    Simon, Y
    CRYOCOOLERS 11, 2001, : 317 - 326
  • [6] Test of a coaxial pulse tube refrigerator with air conditioning compressor
    Liang, JT
    Yang, LW
    Bian, SY
    Zhou, Y
    Zhang, PS
    Zhu, WX
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 25 - 28
  • [7] Movement of linear compressor and displacer in a displacer pulse tube refrigerator
    Zhu, Shaowei
    CRYOGENICS, 2019, 97 : 70 - 76
  • [8] A single stage five valve pulse tube refrigerator reaching 32 K
    Yuan, J
    Pfotenhauer, JM
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 1983 - 1989
  • [9] An experimental investigation of a single-stage two-pulse-tube refrigerator
    Yuan, J
    Pfotenhauer, JM
    CRYOCOOLERS 9, 1997, : 295 - 300
  • [10] Experimental Investigation of a Single-Stage Four-Valve Pulse Tube Refrigerator
    王坤
    鲁雪生
    顾安忠
    Journal of Shanghai Jiaotong University, 2007, (01) : 96 - 99