Vasotrac® arterial blood pressure and direct arterial blood pressure monitoring during liver transplantation

被引:14
|
作者
Findlay, JY [1 ]
Gali, B [1 ]
Keegan, MT [1 ]
Burkle, CM [1 ]
Plevak, DJ [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Anesthesiol, Rochester, MN 55905 USA
来源
ANESTHESIA AND ANALGESIA | 2006年 / 102卷 / 03期
关键词
D O I
10.1213/01.ane.0000196512.96019.e4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
During liver transplantation two arterial catheters are often placed. The Vasotrac (R) is a noninvasive monitor that provides radial arterial blood pressures by a tonometric method. We investigated whether the Vasotrac (R) would be an accurate substitute for an arterial catheter by comparing Vasotrac (R) blood pressures with simultaneous direct radial blood pressures recorded from the contralateral arm in 14 patients undergoing liver transplantation. Correlation between the two methods was calculated and a Bland-Altman analysis performed to assess agreement. A total of 6468 simultaneous measurements were made over a duration of 1.5-7.5 h per case. For mean arterial blood pressure 57% of Vasetrac (R) measurements were within 10% of direct arterial measurement. Correlation (r) was 0.82. Vasotrac (R) bias was + 5.4 mm Hg and limits of agreement were +/- 18.6 mm Fig. For systolic arterial blood pressure 65% of Vasotrac (R) measurements were within 10% of direct arterial measurement. Correlation was 0.78. Vasotrac (R) bias was + 7.6 mm Hg and limits of agreement +/- 25 mm Hg. For diastolic arterial blood pressure 57% of Vasotrac (R) measurements were within 10% of direct arterial measurement. Correlation was 0.82. Vasotrac (R) bias was + 3.3 mm Hg and limits of agreement +/- 15 mm Hg. We conclude that the Vasotrac (R) is not adequately accurate to substitute for direct arterial blood pressure monitoring in liver transplantation.
引用
收藏
页码:690 / 693
页数:4
相关论文
共 50 条
  • [21] Differences between Radial and Femoral Arterial Blood Pressure Measurements during Orthotopic Liver Transplantation
    Lee, Matthew
    Weinberg, Laurence
    Pearse, Brett
    Scurrah, Nicholas
    Story, David
    Pillai, Param
    McCall, Peter
    McNicol, Larry
    Peyton, Philip
    LIVER TRANSPLANTATION, 2014, 20 : S230 - S230
  • [22] THE SIGNIFICANCE OF THE CHANGES IN ARTERIAL BLOOD PRESSURE DURING PRESSURE BREATHING
    HOWARD, P
    JOURNAL OF PHYSIOLOGY-LONDON, 1954, 123 (03): : P36 - P36
  • [23] ARTERIAL BLOOD PRESSURE AFTER PEDIATRIC LIVER TRANSPLANTATION IN ONE CENTER (CHILE)
    Aglony, Marlene
    Vogel, Andrea
    Cristobal Gana, Juan
    Soriano, Humberto
    Carlos Pattillo, Juan
    Dellepiane, Paulina
    PEDIATRIC TRANSPLANTATION, 2011, 15 : 47 - 47
  • [24] DIRECT ARTERIAL BLOOD-PRESSURE MEASUREMENTS - REPLY
    ZSIGMOND, EK
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1981, 246 (16): : 1770 - 1770
  • [25] A METHOD OF MEASURING DIRECT ARTERIAL BLOOD-PRESSURE
    SCULLY, P
    CERVONI, P
    CHAN, PS
    TILLEY, LP
    CANINE PRACTICE, 1983, 10 (03) : 24 - &
  • [26] DIRECT MEASUREMENT OF ARTERIAL BLOOD PRESSURE IN THE GUINEA PIG
    MARSHALL, LH
    HANNA, CH
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1956, 92 (01): : 31 - 32
  • [27] Non-invasive arterial pressure monitoring during liver transplantation.
    Findlay, JY
    Gali, B
    Keegan, MT
    Jankowski, CJ
    Burke, CM
    Plevak, DJ
    LIVER TRANSPLANTATION, 2004, 10 (06) : C2 - C2
  • [28] Principles of Anesthesia Monitoring-Arterial Blood Pressure
    Flegal, Matthew C.
    Fox, Lennie K.
    Kuhlman, Steven M.
    JOURNAL OF INVESTIGATIVE SURGERY, 2009, 22 (02) : 154 - 155
  • [29] Reproducibility of ambulatory blood pressure monitoring in arterial hypertension
    Ribera, L
    Sobrino, J
    Pladevall, M
    Felip, A
    Soler, J
    Modol, J
    Plana, J
    Comes, L
    Adrian, MJ
    Coca, A
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 148A - 148A
  • [30] Continuous indirect arterial blood pressure monitoring and evaluating
    Stork, M
    Holejsovská, P
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, PROCEEDINGS, 2002, : 138 - 140