Sinus node dysfunction in patients with Fontan circulation: could heart rate variability be a predictor for pacemaker implantation?

被引:10
|
作者
Dahlqvist, Jenny Alenius [1 ]
Wiklund, Urban [2 ]
Karlsson, Marcus [2 ]
Hanseus, Katarina [3 ]
Stromvall-Larsson, Eva [4 ]
Nygren, Anders [4 ]
Eliasson, Hakan [5 ]
Rydberg, Annika [1 ]
机构
[1] Umea Univ, Dept Clin Sci, Pediat, S-90185 Umea, Sweden
[2] Umea Univ, Dept Radiat Sci, Biomed Engn, Umea, Sweden
[3] Lund Univ, Skane Univ Hosp, Children Heart Ctr, Dept Clin Sci Lund, Lund, Sweden
[4] Gothenburg Univ, Inst Clin Sci, Sahlgrenska Univ Hosp, Dept Cardiol,Queen Silvia Childrens Hosp, Gothenburg, Sweden
[5] Karolinska Inst, Karolinska Univ Hosp, Dept Womens & Childrens Hlth, Stockholm, Sweden
关键词
Congenital heart disease; Fontan circulation; Pacemaker; Sinus node dysfunction; Heart rate variability; Poincare analysis; QUALITY-OF-LIFE; ADULT PATIENTS; CHILDREN; CAVOPULMONARY; ARRHYTHMIAS; PREVALENCE;
D O I
10.1007/s00246-019-02092-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sinus node dysfunction (SND) causes significant morbidity in patients after Fontan surgery. Heart rate variability (HRV) reflects the autonomic regulation of the heart, and changes in HRV have been associated with SND in adults. We aimed to study whether changes in HRV could be detected in 24-h electrocardiographic (ECG) recordings in Fontan patients with SND. We compared HRV results from two patient groups; patients with Fontan circulation who later required a pacemaker due to severe SND (n = 12) and patients with Fontan circulation and SND, without indication for pacemaker treatment (n = 11), with two control groups; patients with Fontan circulation without SND (n = 90) and healthy controls (n = 66). The Poincare plot index SD2 (representing changes in heart rate over 24-h) and the very low-frequency (VLF) HRV component were significantly higher in both SND groups, both compared with healthy controls and patients with Fontan circulation without SND. In SND patients with pacemakers, SD2 and VLF were slightly reduced compared to SND patients without pacemaker (p = 0.06). In conclusion, in Fontan patients with SND the HRV is significantly higher compared to healthy controls and Fontan patients without SND. However, in patients with severe SND requiring pacemaker, SD2 and VLF tended to be lower than in patients with SND without pacemaker, which could indicate a reduced diurnal HRV in addition to the severe bradycardia. This is a small study, but our results indicate that HRV analysis might be a useful method in the follow-up of Fontan patients regarding development of SND.
引用
收藏
页码:685 / 693
页数:9
相关论文
共 50 条
  • [31] Can Analysis of Heart Rate Variability Predict Arrhythmia in Children with Fontan Circulation?
    A. Rydberg
    M. Karlsson
    R. Hörnsten
    U. Wiklund
    Pediatric Cardiology, 2008, 29 : 50 - 55
  • [32] Heart Rate Variability in Children With Fontan Circulation: Lateral Tunnel and Extracardiac Conduit
    Dahlqvist, Jenny Alenius
    Karlsson, Marcus
    Wiklund, Urban
    Hornsten, Rolf
    Stromvall-Larsson, Eva
    Berggren, Hakan
    Hanseus, Katarina
    Johansson, Sune
    Rydberg, Annika
    PEDIATRIC CARDIOLOGY, 2012, 33 (02) : 307 - 315
  • [33] Intrinsic Sinus Node/Atrioventricular Node Dysfunction Requiring Pacemaker Implantation: Role of Former Professional Sport Activity
    Bondarev, Sergei
    Achkasov, Evgeny
    Zorzi, Alessandro
    Safaryan, Alexandr
    Graziano, Francesca
    Sizov, Alexey
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [34] Handheld ECG in analysis of arrhythmia and heart rate variability in children with Fontan circulation
    Dahlqvist, Jenny Alenius
    Karlsson, Marcus
    Wiklund, Urban
    Hornsten, Rolf
    Rydberg, Annika
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (03) : 374 - 382
  • [35] Heart Rate Variability in Children With Fontan Circulation: Lateral Tunnel and Extracardiac Conduit
    Jenny Alenius Dahlqvist
    Marcus Karlsson
    Urban Wiklund
    Rolf Hörnsten
    Eva Strömvall-Larsson
    Håkan Berggren
    Katarina Hanseus
    Sune Johansson
    Annika Rydberg
    Pediatric Cardiology, 2012, 33 : 307 - 315
  • [36] Factors influencing development of atrial fibrillation after implantation of cardiac pacemaker for sinus node dysfunction
    Aidietis, Audrius
    Barysiene, Jurate
    Marinskis, Germanas
    Aidietiene, Sigita
    Kaireviciute, Diana
    Jurkuvenas, Paulius
    Aganauskiene, Jurate
    Bagdonas, Kestutis
    Jezovas, Vladimiras
    Laucevicius, Aleksandras
    MEDICINA-LITHUANIA, 2009, 45 (03): : 169 - 176
  • [37] AV CONDUCTION DURING FOLLOW-UP OF PATIENTS WITH SYMPTOMATIC SINUS NODE DYSFUNCTION AFTER AAI PACEMAKER IMPLANTATION
    VANMECHELEN, R
    HAGEMEIJER, F
    CIRCULATION, 1984, 70 (04) : 432 - 432
  • [38] Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS duration
    Shukla, HH
    Hellkamp, AS
    James, EA
    Flaker, GC
    Lee, KL
    Sweeney, MO
    Lamas, GA
    HEART RHYTHM, 2005, 2 (03) : 245 - 251
  • [39] Extracardiac Autologous Pericardial Tunnel Fontan Allows Implantation of an Endocardial Atrial Lead for Sinus Node Dysfunction
    Newcombe, Jennifer
    Gordon, Brent
    Razzouk, Anees
    Bailey, Leonard
    Mandapati, Ravi
    ANNALS OF THORACIC SURGERY, 2014, 98 (03): : 1904 - 1096
  • [40] CLASSIFICATION OF CHRONOTROPIC INCOMPETENCE IN PATIENTS WITH SINUS NODE DYSFUNCTION REQUIRING A PERMANENT PACEMAKER
    PRIOR, M
    MASTERSON, M
    WILKOFF, B
    BLACKBURN, G
    MORANT, V
    CASTLE, L
    MALONEY, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1225 - 1225