EXPERIMENTAL STUDIES ON A MARINE VARIABLE-AIR-VOLUME (VAV) AIR-CONDITIONING (A/C) SYSTEM WITH CONSTANT SUPPLY AIR STATIC-PRESSURE CONTROL

被引:0
|
作者
Chen, W. [1 ]
Zheng, C. Y. [1 ]
Guo, J. J. [1 ]
Wang, Y. Q. [1 ]
机构
[1] Jimei Univ, Inst Marine Engn, Xiamen 361021, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Marine air-conditioning (A/C) is one of the major energy consumption devices on ships and consumes about 20% of the ship's total electric energy. Traditional marine A/C usually uses constant-air-volume (CAV) air-distribution system, which usually operates in part-load condition with low energy efficiency. Variable-air-volume (VAV) A/C system can significantly reduce energy consumption. In order to study the operating characteristics of a marine VAV A/C system new-developed and its supply air control strategy, an experimental rig for marine VAV A/C was built. Experimental studies were carried out for the system under two different supply air static-pressure control strategies. Experimental results showed that both strategies can achieve high-quality control for cabin air temperature and desirable independent zoning control. It was found from these experimental studies that the application of VAV A/C system on ships should be feasible.
引用
收藏
页码:927 / 932
页数:6
相关论文
共 50 条
  • [41] Fuzzy Sliding Mode Control of a VAV Air-Conditioning Terminal Temperature System
    Niu, Fuzhou
    Li, Ziyang
    Yang, Lijian
    Wu, Zhengtian
    Zhu, Qixin
    Jiang, Baoping
    [J]. COMPLEXITY, 2020, 2020
  • [42] Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System
    王江江
    安大伟
    张春发
    荆有印
    [J]. Transactions of Tianjin University, 2009, (04) : 308 - 314
  • [43] Genetic Optimization Algorithm of PID Decoupling Control for VAV Air-Conditioning System
    王江江
    安大伟
    张春发
    荆有印
    [J]. Transactions of Tianjin University, 2009, 15 (04) - 314
  • [44] Genetic optimization algorithm of PID decoupling control for VAV air-conditioning system
    Wang J.
    An D.
    Zhang C.
    Jing Y.
    [J]. Transactions of Tianjin University, 2009, 15 (4) : 308 - 314
  • [45] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [46] Room temperature and humidity decoupling control of common variable air volume air-conditioning system based on bilinear characteristics
    Zhang, Yuan
    Yan, Tian
    Xu, Xinhua
    Gao, Jiajia
    Huang, Gongsheng
    [J]. Energy and Built Environment, 2023, 4 (03): : 354 - 367
  • [47] Precision Control for Room Temperature of Variable Air Volume Air-Conditioning Systems with Large Input Delay
    Shi, Jinfeng
    Liu, Haoyang
    Yang, Xiaowei
    [J]. ENERGIES, 2024, 17 (17)
  • [48] Experimental study of model predictive control for an air-conditioning system with dedicated outdoor air system
    Yang, Shiyu
    Wan, Man Pun
    Ng, Bing Feng
    Dubey, Swapnil
    Henze, Gregor P.
    Chen, Wanyu
    Baskaran, Krishnamoorthy
    [J]. APPLIED ENERGY, 2020, 257
  • [49] Simulation design of automatic control system of variable air volume air conditioning under simple air volume control algorithm
    Hu Nan Financial & Industry Vocational-Technical College, Hu Nan
    421000, China
    不详
    不详
    [J]. Int. J. Mech. Appl. Mech, 2020, 8 (70-76):
  • [50] Simulation and experimental validation of the variable-refrigerant-volume (VRV) air-conditioning system in EnergyPlus
    Zhou, Y. P.
    Wu, J. Y.
    Wang, R. Z.
    Shiochi, S.
    Li, Y. M.
    [J]. ENERGY AND BUILDINGS, 2008, 40 (06) : 1041 - 1047