Time-resolved biofilm deformation measurements using optical coherence tomography

被引:76
|
作者
Blauert, Florian [1 ]
Horn, Harald [1 ]
Wagner, Michael [1 ,2 ]
机构
[1] Karlsruhe Inst Technol, Chair Water Chem & Water Technol, D-76131 Karlsruhe, Germany
[2] Karlsruhe Inst Technol, Inst Funct Interfaces, D-76131 Karlsruhe, Germany
关键词
optical coherence tomography; biofilm rheology; mechanical properties; time-resolved deformation; shear and Young's modulus; mesoscale; BACTERIAL BIOFILMS; MASS-TRANSFER; PSEUDOMONAS-AERUGINOSA; FLUID SHEAR; DETACHMENT; MICROSCOPY; RESISTANCE;
D O I
10.1002/bit.25590
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The interaction of shear stress with the biofilm leads to a dynamic deformation, which is related to the structural and material characteristics of biofilms. We show how optical coherence tomography can be used as an imaging technique to investigate the time-resolved deformation on the biofilm mesoscale as well as to estimate mechanical properties of the biofilm. For the first time time-resolved deformation from cross-sectional views of the inner biofilm structure could be shown. Changes in the biofilm structure and rheological properties were calculated from cross sections in real-time and time-lapsed measurements. Heterotrophic biofilms were grown in a flow cell set-up at low shear stress of (w)=0.01Pa. By applying higher shear stress elastic and viscoelastic behavior of biofilms were quantified. Deformation led to a change in biofilm conformation and allowed to estimate rheological properties. Assuming an ideal wall shear stress calculation, the shear modulus G=29.7 +/- 1.7Pa and the Young's modulus E=36.0 +/- 2.6Pa were estimated. Biotechnol. Bioeng. 2015;112: 1893-1905. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1893 / 1905
页数:13
相关论文
共 50 条
  • [31] Time-resolved optical measurements with spread spectrum excitation
    Chen, NG
    Zhu, Q
    OPTICS LETTERS, 2002, 27 (20) : 1806 - 1808
  • [32] TIME-RESOLVED MEASUREMENTS OF PICOSECOND OPTICAL-BREAKDOWN
    ZYSSET, B
    FUJIMOTO, JG
    DEUTSCH, TF
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1989, 93 (03): : 260 - 265
  • [33] TIME-RESOLVED MEASUREMENTS OF PICOSECOND OPTICAL-BREAKDOWN
    ZYSSET, B
    FUJIMOTO, JG
    DEUTSCH, TF
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1989, 48 (02): : 139 - 147
  • [34] Time-resolved optical measurements of detonation and combustion products
    Carney, Joel R.
    Wilkinson, John
    Lightstone, James M.
    SHOCK COMPRESSION OF CONDENSED MATTER - 2007, PTS 1 AND 2, 2007, 955 : 1225 - 1228
  • [35] Optical Delay Lines: Key to Time-Resolved Measurements
    Eftekhari, Ali
    PHOTONICS SPECTRA, 2014, 48 (12) : 35 - 37
  • [36] Investigating Alveolar Mechanics With Time-Resolved Optical Coherence Tomography (oct) And Intravital Microscopy (ivm) In Rats
    Schnabel, C.
    Koch, E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [37] Optical path length measurements on human forehead using time-resolved system
    Okada, E
    Misonoo, S
    Eda, S
    CLEO(R)/PACIFIC RIM 2001, VOL I, TECHNICAL DIGEST, 2001, : 384 - 385
  • [38] An algorithm for localization of optical disturbances in turbid media using time-resolved diffuse optical tomography
    Potlov, A. Yu.
    Frolov, S. V.
    Proskurin, S. G.
    SARATOV FALL MEETING 2017: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XIX, 2018, 10716
  • [39] Investigation of bacterial biofilm in the human middle ear using optical coherence tomography and acoustic measurements
    Nguyen, Cac T.
    Robinson, Sarah R.
    Jung, Woonggyu
    Novak, Michael A.
    Boppart, Stephen A.
    Allen, Jont B.
    HEARING RESEARCH, 2013, 301 : 193 - 200
  • [40] Calibration techniques and datatype extraction for time-resolved optical tomography
    Hillman, EMC
    Hebden, JC
    Schmidt, FEW
    Arridge, SR
    Schweiger, M
    Dehghani, H
    Delpy, DT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (09): : 3415 - 3427