Background: The aim of this study is to analyze the outcomes and incidence of postoperative patient-prothesis mismatch after surgical aortic valve replacement using supra-annular bioprosthesis and transcatheter aortic valve implantation. Methods: Between January 2012 and June 2015, a total of 73 patients (37 males, 36 females; mean age 71.8 +/- 5.7 years; range, 65 to 82 years) who underwent either surgical aortic valve replacement using supraannular bioprosthesis (n=36) or transcatheter aortic valve implantation (n=37) were included. Postoperative patient-prothesis mismatch was defined as absent, mild-to-moderate, and severe, if the indexed effective orifice area was >0.85 cm(2)/m(2), >0.65 to <0.85 cm(2)/m(2), and <0.65 cm(2)/m(2), respectively. Both groups were compared in terms of patient-prothesis mismatch, postoperative outcomes, and mortality. Results: The overall incidence of mild-to-moderate patient-prosthesis mismatch was 17.8% (13/73). No severe patient-prosthesis mismatch was observed. Mild-to-moderate patient-prosthesis mismatch was found in three patients (8.1%) in the transcatheter group and in 10 patients (27.8%) in the surgery group (p=0.035). Body surface area was the significant predictor of patient-prosthesis mismatch (p=0.007). Diameters of bioprosthetic valves in the surgery and transcatheter groups were 21.4 +/- 2 and 23.9 +/- 2.6 mm, respectively (p=0.002). Early mortality and pacemaker implantation rates were higher in the transcatheter group (p>0.05). Postoperative outcomes were similar between the groups. Mid-term mortality at a mean follow-up of 47.7 +/- 7.3 months was similar between the groups (p=0.158). Conclusion: In high-risk patients with severe aortic stenosis, patient-prosthesis mismatch is mild-to-moderate after surgical aortic valve replacement and transcatheter aortic valve implantation; however, this has no effect on early mortality. Based on our study results, we suggest that the use of surgical approach for aortic valve replacement may prevent potential complications of transcatheter aortic valve implantation.
引用
收藏
页码:143 / 151
页数:9
相关论文
共 50 条
  • [31] Transcatheter aortic valve implantation 10 years after valve-in-valve transcatheter aortic valve implantation for failing aortic valve homograft root replacement
    Duncan, Alison
    Mirsadree, Saeed
    Quarto, Cesare
    Davies, Simon
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 96 (01) : 228 - 235
  • [32] Surgical aortic valve replacement vs. transcatheter aortic valve implantation in octogenarians
    Jeger, R.
    Rueter, F.
    Leibundgut, G.
    Kaiser, C.
    Eckstein, F.
    Buser, P.
    Reuthebuch, O.
    EUROPEAN HEART JOURNAL, 2010, 31 : 955 - 955
  • [33] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [34] Rates of Late Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement
    Kawsara, Akram
    Berzingi, Chalak
    Alkhouli, Mohamad
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 182 : 104 - 105
  • [36] Aortic valve replacement vs. transcatheter aortic valve implantation: Patient selection
    Ye, Jian
    Soon, Jia Lin
    Webb, John
    ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (02) : 194 - 199
  • [37] Transcatheter aortic valve implantation in a cancer patient denied for surgical aortic valve replacement-a case report
    Mrak, Miha
    Ambrozic, Jana
    Music, Spela
    Terseglav, Simon
    Kontestabile, Bojan
    Lakic, Nikola
    Bunc, Matjaz
    WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (13-14) : 516 - 520
  • [38] Patient-Prosthesis Mismatch After Aortic Valve Intervention Another Win for Transcatheter Aortic Valve Replacement
    Prendergast, Bernard D.
    McConkey, Hannah Z. R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (08) : 781 - 783
  • [39] Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis
    Ghanta, Ravi K.
    Kron, Irving L.
    JOURNAL OF THORACIC DISEASE, 2016, 8 (10) : E1441 - E1443
  • [40] Is Transcatheter Aortic Valve Replacement Superior to Surgical Aortic Valve Replacement?
    Pagnesi, Matteo
    Chiarito, Mauro
    Stefanini, Giulio G.
    Testa, Luca
    Reimers, Bernhard
    Colombo, Antonio
    Latib, Azeem
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (18) : 1899 - 1901