A novel multi-frequency electrical impedance tomography spectral imaging algorithm for early stroke detection

被引:32
|
作者
Yang, Lin [1 ]
Xu, Canhua [1 ]
Dai, Meng [1 ]
Fu, Feng [1 ]
Shi, Xuetao [1 ]
Dong, Xiuzhen [1 ]
机构
[1] Fourth Mil Med Univ, Dept Biomed Engn, Xian 710032, Peoples R China
基金
中国国家自然科学基金;
关键词
electrical impedance tomography; spectral imaging; stroke; FREQUENCY-DIFFERENCE EIT; HEAD-SHAPED TANK; RECONSTRUCTION ALGORITHMS; VALIDATION; PHANTOM; SKULL; FDEIT;
D O I
10.1088/1361-6579/37/12/2317
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Multi-frequency electrical impedance tomography (MFEIT) reconstructs the image of conductivity inside the human body based on the dependence of tissue conductivity on frequency. As there exist differences in the conductivity over frequency between blood, ischemic cortical tissue and normal cortical tissue, MFEIT has potential application in the detection of acute stroke. However, because the conductivity distribution of the human head is highly inhomogeneous and the conductivities of normal head tissue and stroke lesion tissue both change with frequency, the anomaly and normal head tissues are often mixed together in the reconstructed image, which makes it difficult to discern the anomaly. Here we present a spectral decomposition frequency-difference (SD-FD) imaging algorithm in an attempt to address this issue: firstly, we reconstruct so-called EIT spectral images according to the conductivity spectra of tissues; secondly, we obtain the EIT image of the anomaly from the spectral images by using independent component analysis. The results show that the proposed algorithm is capable of detecting the anomaly in a numerical head phantom, as well as in a realistic human head tank with frequency-dependent and heterogeneous conductivities distribution. The proposed SD-FD algorithm may support MFEIT use for human stroke imaging in the future.
引用
收藏
页码:2317 / 2335
页数:19
相关论文
共 50 条
  • [11] Tissue characterization using a multi-frequency of electrical impedance tomography
    Shallof, A.M.
    Barber, D.C.
    IEE Colloquium (Digest), 1996, (143):
  • [12] Multi-frequency symmetry difference electrical impedance tomography with machine learning for human stroke diagnosis
    McDermott, Barry
    Elahi, Adnan
    Santorelli, Adam
    O'Halloran, Martin
    Avery, James
    Porter, Emily
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (07)
  • [13] Design of current source for multi-frequency simultaneous electrical impedance tomography
    Han, Bing
    Xu, Yanbin
    Dong, Feng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (09):
  • [14] Multi-frequency electrical impedance tomography: Tissue characterisation and image quality
    Shallof, AM
    Barber, DC
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 699 - 707
  • [15] On the Implementation of Simultaneous Multi-Frequency Excitations and Measurements for Electrical Impedance Tomography
    Darnajou, Mathieu
    Dupre, Antoine
    Dang, Chunhui
    Ricciardi, Guillaume
    Bourennane, Salah
    Bellis, Cedric
    SENSORS, 2019, 19 (17)
  • [16] Multi-frequency electrical impedance tomography of the breast: new clinical results
    Soni, NK
    Hartov, A
    Kogel, C
    Poplack, SP
    Paulsen, KD
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 301 - 314
  • [17] Use of Multi-frequency Electrical Impedance Tomography as Tactile Sensor for Material Discrimination
    Abdelwahed, Mehdi
    Pitti, Alexandre
    Romain, Olivier
    Ben Ouezdou, Fethi
    2020 5TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2020), 2020, : 588 - 594
  • [18] Modular architecture of a Multi-frequency Electrical Impedance Tomography system: design and implementation
    Fouchard, Alexandre
    Noca, Alain
    Bonnet, Stephane
    Pham, Pascale
    Sinniger, Valerie
    Clarencon, Didier
    David, Olivier
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6080 - 6083
  • [19] Digital Demodulation in data acquisition system for multi-frequency electrical impedance tomography
    Shi Xuetao
    You Fusheng
    Ji Zhenyu
    Fu Feng
    Liu Ruigang
    Dong Xiuzhen
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [20] Research on frequency robustness of multi-frequency electrical impedance tomography based on Four-Parameter Sine-fit algorithm
    Qiu, Maolin
    Hu, Xuehai
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ALGORITHMS, SOFTWARE ENGINEERING, AND NETWORK SECURITY, ASENS 2024, 2024, : 296 - 300