Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study

被引:21
|
作者
Bhaumik, Uttam [1 ]
Ghosh, Animesh [1 ]
Sarkar, Amlan Kanti [1 ]
Bose, Anirbandeep [1 ]
Selvan, P. Senthamil [1 ]
Sengupta, Pinaki [1 ]
Chakraborty, Way Sankar [1 ]
Ghosh, Debotri [1 ]
Pal, Tapan Kumar [1 ]
机构
[1] Jadavpur Univ, Dept Pharmaceut Technol, Bioequivalence Study Ctr, Kolkata 700032, India
关键词
Ranolazine; Human plasma; Quantification; LC-MS/MS; Bioequivalence;
D O I
10.1016/j.jpba.2008.09.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantification of ranolazine in human plasma. The analytical method consists in the precipitation of plasma sample with methanol, followed by the determination of ranolazine by an LC-MS/MS. The analyte was separated on a Peerless Cyano column (33 mm x 4.6 mm, 3 mu m) an isocratic mobile phase of methanol-water containing formic acid (1.0%, v/v) (65:35, v/v) at a flow rate of 1.0 ml/min. Protonated ions formed by a turbo ionspray in positive mode were used to detect analyte and internal standard (IS). The MS/MS detection was made by monitoring the fragmentation of m/z 428.20 -> 279.50 for ranolazine and m/z 448.30 -> 285.20 for internal standard on a triple quadrupole mass spectrometer. The method was validated over the concentration range of 5-2000 ng/ml for ranolazine in human plasma with correlation coefficient of 0.9937 (S.D.: +/- 0.00367, range: 0.9895-0.9963). The accuracy and precision values obtained from six different sets of quality control samples analyzed in separate occasions ranged from 94.53 to 117.86 and 0.14% to 4.56%, respectively. Mean extraction recovery was 82.36-94.25% for three quality control (QC) samples and 88.37% for IS. Plasma samples were stable for three freeze-thaw cycles, or 24 h ambient storage, or I and 3 months storage at -20 degrees C. Processed samples (ready for injection) were stable up to 72 h at autosampler (4 degrees C). The developed method was successfully applied for analyzing ranolazine in plasma samples for a bioequivalence study with 12 healthy volunteers. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1404 / 1410
页数:7
相关论文
共 50 条
  • [21] Simultaneous determination of enalapril and enalaprilat in human plasma by LC-MS: Application to a bioequivalence study
    Wang, Ping
    Liang, Yi-Zeng
    Chen, Ben-Mei
    Zhou, Neng
    Yi, Lun-Zhao
    Yu, Yan
    Yi, Zhi-Biao
    CHROMATOGRAPHIA, 2007, 65 (3-4) : 209 - 215
  • [22] Development and Validation of LC-MS Method for the Determination of Lisinopril in Human Plasma and its Application in a Bioequivalence Study
    Zhou, Neng
    Liang, Yi-zeng
    Chen, Ben-mei
    Wang, Ping
    Chen, Man
    Liu, Feng-ping
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (10) : 848 - 853
  • [23] Simultaneous Determination of Enalapril and Enalaprilat in Human Plasma by LC-MS: Application to a Bioequivalence Study
    Ping Wang
    Yi-Zeng Liang
    Ben-Mei Chen
    Neng Zhou
    Lun-Zhao Yi
    Yan Yu
    Zhi-Biao Yi
    Chromatographia, 2007, 65 : 209 - 215
  • [24] DETERMINATION OF TROPISETRON IN HUMAN PLASMA BY LC-MS/MS AND ITS APPLICATION TO A PHARMACOKINETIC STUDY
    Xu, Hongrong
    DRUG METABOLISM REVIEWS, 2008, 40 : 44 - 44
  • [25] Determination of ospemifene in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Yadlapalli, Siva Sankara Rao
    Katari, Naresh Kumar
    Surya, Surendra Babu Manabolu
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (04)
  • [26] Determination of lacosamide in human plasma by LC-MS/MS and its application to a human pharmacokinetic study
    Yadlapalli, Siva Sankara Rao
    Katari, Naresh Kumar
    Surya, Surendra Babu Manabolu
    SEPARATION SCIENCE PLUS, 2020, 3 (06): : 216 - 224
  • [27] Determination of ergocalciferol in human plasma after Diels-Alder derivatization by LC-MS/MS and its application to a bioequivalence study
    Contractor, Pritesh
    Gandhi, Abhishek
    Solanki, Gajendra
    Shah, Priyanka A.
    Shrivastav, Pranav S.
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2017, 7 (06) : 417 - 422
  • [28] Sensitive LC-MS/MS Method for the Determination of Ramipril in Human Plasma: Application to a Bioequivalence Study in Indian Volunteers
    Saha, Arabinda
    Vats, Poonam
    Gurule, Sanjay Jagannath
    Khuroo, Arshad
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2017, 12 (01) : 90 - 104
  • [29] Determination of amlodipine, indapamide and perindopril in human plasma by a novel LC-MS/MS method: Application to a bioequivalence study
    Rezk, Mamdouh R.
    Badr, Kamal A.
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (05)
  • [30] Development and Validation of a Sensitive LC-MS/MS Method for Determination of Valacyclovir in Human Plasma: Application to a Bioequivalence Study
    Konda, R. K.
    Chandu, B. R.
    Challa, B. R.
    Chandrasekhar, K. B.
    ACTA CHROMATOGRAPHICA, 2013, 25 (04) : 669 - 686