Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study

被引:21
|
作者
Bhaumik, Uttam [1 ]
Ghosh, Animesh [1 ]
Sarkar, Amlan Kanti [1 ]
Bose, Anirbandeep [1 ]
Selvan, P. Senthamil [1 ]
Sengupta, Pinaki [1 ]
Chakraborty, Way Sankar [1 ]
Ghosh, Debotri [1 ]
Pal, Tapan Kumar [1 ]
机构
[1] Jadavpur Univ, Dept Pharmaceut Technol, Bioequivalence Study Ctr, Kolkata 700032, India
关键词
Ranolazine; Human plasma; Quantification; LC-MS/MS; Bioequivalence;
D O I
10.1016/j.jpba.2008.09.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantification of ranolazine in human plasma. The analytical method consists in the precipitation of plasma sample with methanol, followed by the determination of ranolazine by an LC-MS/MS. The analyte was separated on a Peerless Cyano column (33 mm x 4.6 mm, 3 mu m) an isocratic mobile phase of methanol-water containing formic acid (1.0%, v/v) (65:35, v/v) at a flow rate of 1.0 ml/min. Protonated ions formed by a turbo ionspray in positive mode were used to detect analyte and internal standard (IS). The MS/MS detection was made by monitoring the fragmentation of m/z 428.20 -> 279.50 for ranolazine and m/z 448.30 -> 285.20 for internal standard on a triple quadrupole mass spectrometer. The method was validated over the concentration range of 5-2000 ng/ml for ranolazine in human plasma with correlation coefficient of 0.9937 (S.D.: +/- 0.00367, range: 0.9895-0.9963). The accuracy and precision values obtained from six different sets of quality control samples analyzed in separate occasions ranged from 94.53 to 117.86 and 0.14% to 4.56%, respectively. Mean extraction recovery was 82.36-94.25% for three quality control (QC) samples and 88.37% for IS. Plasma samples were stable for three freeze-thaw cycles, or 24 h ambient storage, or I and 3 months storage at -20 degrees C. Processed samples (ready for injection) were stable up to 72 h at autosampler (4 degrees C). The developed method was successfully applied for analyzing ranolazine in plasma samples for a bioequivalence study with 12 healthy volunteers. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1404 / 1410
页数:7
相关论文
共 50 条
  • [1] Determination of quetiapine in human plasma by LC-MS/MS and its application in a bioequivalence study
    Li, Min
    Zhang, Shuo
    Shi, Aixin
    Qi, Wenyuan
    Liu, Yao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 : 10 - 14
  • [2] Determination of amoxicillin in human plasma by LC-MS/MS and its application to a bioequivalence study
    Pingale, Satish G.
    Badgujar, Madhukara
    Mangaonkar, Kiran V.
    Mastorakis, Nikos E.
    PROCEEDINGS OF THE WORLD MEDICAL CONFERENCE, 2010, : 86 - +
  • [3] Determination of lacidipine in human plasma by LC-MS/MS: Application in a bioequivalence study
    Chen, Hao
    Li, Lan
    Song, Shuai
    Du, Yan
    Jin, Xiaoqin
    Ding, PeiPei
    Shen, Chenlin
    Huang, Xiaohui
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2018, 56 (10) : 493 - 500
  • [4] LC-MS/MS Method for Determination of Megestrol in Human Plasma and Its Application in Bioequivalence Study
    李帆
    邹小娟
    郑恒
    向一
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2013, 33 (06) : 912 - 916
  • [5] LC-MS/MS Method for Determination of Megestrol in Human Plasma and Its Application in Bioequivalence Study
    Li, Fan
    Zou, Xiao-juan
    Zheng, Heng
    Xiang, Yi
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (06) : 912 - 916
  • [6] LC-MS/MS method for determination of megestrol in human plasma and its application in bioequivalence study
    Fan Li
    Xiao-juan Zou
    Heng Zheng
    Yi Xiang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 912 - 916
  • [7] LC-MS/MS Analytical Method for Determination of Montelukast in Human Plasma and its Application to a Bioequivalence Study
    Said, Rana
    CURRENT PHARMACEUTICAL ANALYSIS, 2023, 19 (02) : 163 - 175
  • [8] A Sensitive LC-MS/MS Method for the Determination of Afatinib in Human Plasma and Its Application to a Bioequivalence Study
    Luo, Xi
    Zhang, Xiu Jin
    Zhu, Wen Ling
    Yi, Jin Ling
    Xiong, Wen Gang
    Ye, Feng
    Zheng, Chao
    Fan, Ming Xia
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (01) : 61 - 67
  • [9] LC-MS/MS assay for olanzapine in human plasma and its application to a bioequivalence study
    Patel, Dinesh S.
    Sharma, Naveen
    Patel, Mukesh C.
    Patel, Bhavin N.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    ACTA PHARMACEUTICA SINICA B, 2012, 2 (05) : 481 - 494
  • [10] Development of a simple LC-MS/MS method for determination of rebamipide in human plasma and its application to a bioequivalence study
    Liu, Jian
    Shen-Tu, Jianzhong
    Wu, Lihua
    Dou, Jing
    Xu, Qiyang
    Zhou, Huili
    Wu, Guolan
    Hu, Xingjiang
    PHARMAZIE, 2012, 67 (11): : 906 - 911