Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

被引:29
|
作者
Bindhu, K. R. [1 ]
Jaya, K. P. [2 ]
Selvam, Manicka V. K. [3 ]
机构
[1] Coll Engn, Dept Civil Engn, Thiruvananthapuram 695016, Kerala, India
[2] Anna Univ, Struct Engn Div, Madras 600025, Tamil Nadu, India
[3] Natl Inst Technol, Dept Civil Engn, Calicut, Kerala, India
关键词
beam-column joint; confinement; cyclic loading; design; detailing; equilibrium; seismic analysis; strong column-weak beam;
D O I
10.12989/sem.2008.30.6.733
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed non-conventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with non-conventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type I and Type 3 respectively. The present Study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.
引用
下载
收藏
页码:733 / 761
页数:29
相关论文
共 50 条
  • [31] Modelling exterior unreinforced beam-column joints in seismic analysis of non-ductile RC frames
    De Risi, Maria Teresa
    Ricci, Paolo
    Verderame, Gerardo M.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2017, 46 (06): : 899 - 923
  • [32] Parameters for shear strength prediction of exterior beam-column joints without transverse reinforcement
    Park, Sangjoon
    Mosalam, Khalid M.
    ENGINEERING STRUCTURES, 2012, 36 : 198 - 209
  • [33] High-Strength Reinforcement in Exterior Beam-Column Joints under Cyclic Loading
    Lee, Hung-Jen
    Chang, Chia-Jung
    ACI STRUCTURAL JOURNAL, 2017, 114 (05) : 1325 - 1338
  • [34] Assessment of Influence of Reinforcement Detailing on Blast Resistance of Reinforced Concrete Beam-column Connections
    Waqas, Hafiz Ahmed
    Husnain, Ali
    Ubaid, Hassan
    Khan, Adil Poshad
    Shah, Mati Ullah
    Ilyas, Muhammad
    Waseem, Muhammad
    JOURNAL OF MATERIALS AND ENGINEERING STRUCTURES, 2023, 10 (03): : 357 - 374
  • [35] Seismic behavior of reinforced concrete exterior beam-column joints strengthened by ferrocement composites
    Li, Bo
    Lam, Eddie Siu-shu
    Wu, Bo
    Wang, Ya-yong
    EARTHQUAKES AND STRUCTURES, 2015, 9 (01) : 233 - 256
  • [36] Seismic load tests on interior and exterior beam-column joints with substandard reinforcing details
    Hakuto, S
    Park, R
    Tanaka, H
    ACI STRUCTURAL JOURNAL, 2000, 97 (01) : 11 - 25
  • [37] Modelling of exterior RC beam-column joints for the seismic assessment of RC-frames
    Grande, Ernesto
    Imbimbo, Maura
    Napoli, Annalisa
    Nitiffi, Riccardo
    Realfonzo, Roberto
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 582 - 589
  • [38] Seismic Performance of Interior and Exterior Beam-Column Joints in Recycled Aggregate Concrete Frames
    Hu, Bo
    Kundu, Tribikram
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (03)
  • [39] Experimental and Numerical Investigation on Seismic Performance of RC Exterior Beam-Column Joints with Slabs
    Wang, Zhimeng
    Huang, Jiao
    Chang, Zhaoqun
    Lu, Yongjian
    SHOCK AND VIBRATION, 2022, 2022
  • [40] Seismic Performance of GFRP-RC Exterior Beam-Column Joints with Lateral Beams
    Ghomi, Shervin K.
    El-Salakawy, Ehab
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (01)