Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing

被引:29
|
作者
Bindhu, K. R. [1 ]
Jaya, K. P. [2 ]
Selvam, Manicka V. K. [3 ]
机构
[1] Coll Engn, Dept Civil Engn, Thiruvananthapuram 695016, Kerala, India
[2] Anna Univ, Struct Engn Div, Madras 600025, Tamil Nadu, India
[3] Natl Inst Technol, Dept Civil Engn, Calicut, Kerala, India
关键词
beam-column joint; confinement; cyclic loading; design; detailing; equilibrium; seismic analysis; strong column-weak beam;
D O I
10.12989/sem.2008.30.6.733
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The failure of reinforced concrete structures in recent earthquakes caused concern about the performance of beam column joints. Confinement of joint is one of the ways to improve the performance of beam column joints during earthquakes. This paper describes an experimental study of exterior beam-column joints with two non-conventional reinforcement arrangements. One exterior beam-column joint of a six story building in seismic zone III of India was designed for earthquake loading. The transverse reinforcement of the joint assemblages were detailed as per IS 13920:1993 and IS 456:2000 respectively. The proposed non-conventional reinforcement was provided in the form of diagonal reinforcement on the faces of the joint, as a replacement of stirrups in the joint region for joints detailed as per IS 13920 and as additional reinforcement for joints detailed as per IS 456. These newly proposed detailing have the basic advantage of reducing the reinforcement congestion at the joint region. In order to study and compare the performance of joint with different detailing, four types of one-third scale specimens were cast (two numbers in each type). The main objective of the present study is to investigate the effectiveness of the proposed reinforcement detailing. All the specimens were tested under reverse cyclic loading, with appropriate axial load. From the test results, it was found that the beam-column joint having confining reinforcement as per IS: 456 with non-conventional detailing performed well. Test results indicate that the non-conventionally detailed specimens, Type 2 and Type 4 have an improvement in average ductility of 16% and 119% than their conventionally detailed counter parts (Type1 and Type 3). Further, the joint shear capacity of the Type 2 and Type 4 specimens are improved by 8.4% and 15.6% than the corresponding specimens of Type I and Type 3 respectively. The present Study proposes a closed form expression to compute the yield and ultimate load of the system. This is accomplished using the theory of statics and the failure pattern observed during testing. Good correlation is found between the theoretical and experimental results.
引用
下载
收藏
页码:733 / 761
页数:29
相关论文
共 50 条
  • [1] Evaluation of seismic resistance of exterior beam-column joints with detailing as per IS 13920: 1993
    Anna University, Government College of Technology, Coimbatore
    不详
    Indian Concr J, 2006, 2 (29-34):
  • [2] Exterior beam-column joint study with non-conventional reinforcement detailing using mechanical anchorage under reversal loading
    Rajagopal, S.
    Prabavathy, S.
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2014, 39 (05): : 1185 - 1200
  • [3] Exterior beam-column joint study with non-conventional reinforcement detailing using mechanical anchorage under reversal loading
    S RAJAGOPAL
    S PRABAVATHY
    Sadhana, 2014, 39 : 1185 - 1200
  • [4] New Reinforcement Detailing for Concrete Jacketing of Nonductile Exterior Beam-Column Joints
    Bindhu, K. R.
    Mohana, N.
    Sivakumar, S.
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2016, 30 (01)
  • [6] Effect of confinement on the seismic performance of reinforced concrete exterior beam-column joints
    Asha, P.
    Sundararajan, R.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2018, 19 (01) : 59 - 66
  • [7] Predicting Strength of Exterior Wide Beam-Column Joints for Seismic Resistance
    Huang, Roy Y. C.
    Kuang, J. S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (02)
  • [8] Effectiveness of reinforcement details in exterior reinforced concrete beam-column joints for earthquake resistance
    Murty, CVR
    Rai, DC
    Bajpai, KK
    Jain, SK
    ACI STRUCTURAL JOURNAL, 2003, 100 (02) : 149 - 156
  • [9] Seismic performance of RC exterior wide beam-column joints
    Jiang, Qing
    Su, Wenji
    Feng, Yulong
    Shen, Jie
    Fan, Yonglong
    Xuan, Dianchun
    STRUCTURAL CONCRETE, 2024, : 5037 - 5055
  • [10] Seismic resistance and mechanical behaviour of exterior beam-column joints with crossed inclined bars
    Bakir, PG