Using Hyperpolarized 129Xe MRI to Quantify the Pulmonary Ventilation Distribution

被引:69
|
作者
He, Mu [1 ,2 ]
Driehuys, Bastiaan [1 ,3 ,4 ]
Que, Loretta G. [5 ]
Huang, Yuh-Chin T. [5 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[2] Duke Univ, Dept Elect & Comp Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Dept Radiol, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
[5] Duke Univ, Med Ctr, Dept Med, 1821 Hillandale Rd,Suite 25A, Durham, NC 27710 USA
关键词
Asthma; aging; albuterol; REGIONAL FRACTIONAL VENTILATION; INERT-GAS WASHOUT; LUNG CLEARANCE INDEX; HE-3; MRI; CYSTIC-FIBROSIS; COLLATERAL VENTILATION; PERFUSION INEQUALITY; AIRWAY-OBSTRUCTION; HEALTHY-VOLUNTEERS; BREATHING AIR;
D O I
10.1016/j.acra.2016.07.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Ventilation heterogeneity is impossible to detect with spirometry. Alternatively, pulmonary ventilation can be imaged three-dimensionally using inhaled Xe-129 magnetic resonance imaging (MRI). To date, such images have been quantified primarily based on ventilation defects. Here, we introduce a robust means to transform Xe-129 MRI scans such that the underlying ventilation distribution and its heterogeneity can be quantified. Materials and Methods: Quantitative Xe-129 ventilation MRI was conducted in 12 younger (24.7 +/- 5.2 years) and 10 older (62.2 +/- 7.2 years) healthy individuals, as well as in 9 younger (25.9 +/- 6.4 yrs) and 10 older (63.2 +/- 6.1 years) asthmatics. The younger healthy population was used to establish a reference ventilation distribution and thresholds for six intensity bins. These bins were used to display and quantify the ventilation defect region (VDR), the low ventilation region (LVR), and the high ventilation region (HVR). Results: The ventilation distribution in young subjects was roughly Gaussian with a mean and standard deviation of 0.52 0.18, resulting in VDR = 2.1 +/- 1.3%, LVR = 15.6 +/- 5.4%, and HVR = 17.4 +/- 3.1%. Older healthy volunteers exhibited a significantly right skewed distribution (0.46 +/- 0.20, P = 0.034), resulting in significantly increased VDR (7.0 +/- 4.8%, P = 0.008) and LVR (24.5 +/- 11.5%, P = 0.025). In the asthmatics, VDR and LVR increased in the older population, and HVR was significantly reduced (13.5 +/- 4.6% vs 18.9 +/- 4.5%, P = 0.009). Quantitative Xe-129 MRI also revealed altered ventilation heterogeneity in response to albuterol in two asthmatics with normal spirometry. Conclusions: Quantitative Xe-129 MRI provides a robust and objective means to display and quantify the pulmonary ventilation distribution, even in subjects who have airway function impairment not appreciated by spirometry.
引用
收藏
页码:1521 / 1531
页数:11
相关论文
共 50 条
  • [1] Hyperpolarized 129xe Ventilation And Diffusion Mri Of Lymphangioleiomyomatosis
    Walkup, L. L.
    Thomen, R.
    Freeman, M.
    Cleveland, Z.
    McCormack, F. X.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195
  • [2] Using hyperpolarized 129Xe MRI to quantify regional gas transfer in idiopathic pulmonary fibrosis
    Wang, Jennifer M.
    Robertson, Scott H.
    Wang, Ziyi
    He, Mu
    Virgincar, Rohan S.
    Schrank, Geoffry M.
    Smigla, Rose Marie
    O'Riordan, Thomas G.
    Sundy, John
    Ebner, Lukas
    Rackley, Craig R.
    McAdams, Page
    Driehuys, Bastiaan
    THORAX, 2018, 73 (01) : 21 - 28
  • [3] MRI of stroke using hyperpolarized 129Xe
    Zhou, Xin
    Sun, Yanping
    Mazzanti, Mary
    Henninger, Nils
    Mansour, Joey
    Fisher, Marc
    Albert, Mitchell
    NMR IN BIOMEDICINE, 2011, 24 (02) : 170 - 175
  • [4] Preclinical MRI Using Hyperpolarized 129Xe
    Kadlecek, Stephen
    Friedlander, Yonni
    Virgincar, Rohan S.
    MOLECULES, 2022, 27 (23):
  • [5] Hyperpolarized 129xe Mri To Quantify Regional Ventilation Differences In Older Versus Younger Asthmatics
    He, M.
    Heacock, T.
    Kaushik, S. S.
    Robertson, S. H.
    Freeman, M. S.
    McAdams, H. P.
    Beaver, D.
    Kraft, M.
    Driehuys, B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [6] Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
    Doganay, Ozkan
    Matin, Tahreema N.
    Mcintyre, Anthony
    Burns, Brian
    Schulte, Rolf F.
    Gleeson, Fergus V.
    Bulte, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2597 - 2606
  • [7] Extending Semiautomatic Ventilation Defect Analysis for Hyperpolarized 129Xe Ventilation MRI
    He, Mu
    Kaushik, S. Sivaram
    Robertson, Scott H.
    Freeman, Matthew S.
    Virgincar, Rohan S.
    McAdams, H. Page
    Driehuys, Bastiaan
    ACADEMIC RADIOLOGY, 2014, 21 (12) : 1530 - 1541
  • [8] Human Pulmonary Hyperpolarized 129Xe MRI: a Preliminary Study
    杨昊
    王科
    张会婷
    谢军帅
    吴光耀
    周欣
    Chinese Physics Letters, 2018, 35 (05) : 169 - 172
  • [9] Human Pulmonary Hyperpolarized 129Xe MRI: a Preliminary Study
    Yang, Hao
    Wang, Ke
    Zhang, Hui-Ting
    Xie, Jun-Shuai
    Wu, Guang-Yao
    Zhou, Xin
    CHINESE PHYSICS LETTERS, 2018, 35 (05)
  • [10] Dose and pulse sequence considerations for hyperpolarized 129Xe ventilation MRI
    He, Mu
    Robertson, Scott H.
    Kaushik, S. Sivaram
    Freeman, Matthew S.
    Virgincar, Rohan S.
    Davies, John
    Stiles, Jane
    Foster, William M.
    McAdams, H. Page
    Driehuys, Bastiaan
    MAGNETIC RESONANCE IMAGING, 2015, 33 (07) : 877 - 885