Ion parking during ion/ion reactions in electrodynamic ion traps

被引:104
|
作者
McLuckey, SA [1 ]
Reid, GE [1 ]
Wells, JM [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
D O I
10.1021/ac0109671
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Under appropriate ion density conditions, it is possible to selectively inhibit rates of ion/ion reactions in a quadrupole ion trap via the application of oscillatory voltages to one or more electrodes of the ion trap. The phenomenon is demonstrated using dipolar resonance excitation applied to the end-cap electrodes of a three-dimensional quadrupole ion trap. The application of a resonance excitation voltage tuned to inhibit the ion/ion reaction rate of a specific range of ion mass-to-charge ratios is referred to as "ion parking". The bases for rate inhibition are (i) an increase in the relative velocity of the ion/ion reaction pair, which reduces the cross section for ion/ion capture and, at least in some cases, (ii) reduction in the time of physical overlap of positively charged and negatively charged ion clouds. The efficiency and specificity of the ion parking experiment is highly dependent upon ion densities, trapping conditions, ion charge states, and resonance excitation conditions. The ion parking experiment is illustrated herein along with applications to the concentration of ions originally present over a range of charge states into a selected charge state and in the selection of a particular ion from a set of ions derived from a simple protein mixture.
引用
收藏
页码:336 / 346
页数:11
相关论文
共 50 条
  • [31] Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry
    Clowers, Brian H.
    Ibrahim, Yehia M.
    Prior, David C.
    Danielson, William F., III
    Belov, Mikhail E.
    Smith, Richard D.
    ANALYTICAL CHEMISTRY, 2008, 80 (03) : 612 - 623
  • [32] Ion creation, ion focusing, ion/molecule reactions, ion separation, and ion detection in the open air in a small plastic device
    Baird, Zane
    Wei, Pu
    Cooks, R. Graham
    ANALYST, 2015, 140 (03) : 696 - 700
  • [33] An Ion Trap-Ion Mobility-Time of Flight Mass Spectrometer with Three Ion Sources for Ion/Ion Reactions
    Zhao, Qin
    Soyk, Matthew W.
    Schieffer, Gregg M.
    Fuhrer, Katrin
    Gonin, Marc M.
    Houk, R. S.
    Badman, Ethan R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) : 1549 - 1561
  • [34] Mutual storage mode ion/ion reactions in a hybrid linear ion trap
    Yu, X
    Jin, W
    McLuckey, SA
    Londry, FA
    Hager, JW
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (01) : 71 - 81
  • [35] Transmission Mode Ion/Ion Proton Transfer Reactions in a Linear Ion Trap
    Liang, Xiaorong
    McLuckey, Scott A.
    Journal of the American Society for Mass Spectrometry, 2007, 18 (05): : 882 - 890
  • [36] Transmission mode ion/ion proton transfer reactions in a linear ion trap
    Liang, Xiaorong
    McLuckey, Scott A.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (05) : 882 - 890
  • [37] ION ELEMENT RADII IN ELECTRODYNAMIC APPROXIMATION
    BALDANOV, MM
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII KHIMIYA I KHIMICHESKAYA TEKHNOLOGIYA, 1986, 29 (04): : 113 - 115
  • [38] Variable field ion traps
    Sonalikar, Hrishikesh S.
    Mohanty, Atanu K.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 356 : 60 - 70
  • [39] ELECTRODYNAMIC LIQUID METAL ION SOURCE
    MAHONEY, J
    MOORE, RD
    YAHIKU, AY
    DALEY, HL
    PEREL, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (12): : 1651 - &
  • [40] Quantum computations on ion traps
    Burkov, A.
    Ozhigov, Y.
    QUANTUM INFORMATICS 2007, 2008, 7023